• Title/Summary/Keyword: Built-in Pressure ratio

Search Result 55, Processing Time 0.032 seconds

An experimental study on the flow characteristics of a 2-D supersonic turbine with pressure ratio (압력비에 따른 2차원 초음속 터빈의 유동특성에 대한 실험적 연구)

  • Jeong Soo-In;Kim Kui-Soon;Kim Jin-Han;Lee Eun-Seok;Cho Jong-Jae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.99-108
    • /
    • 2004
  • In this paper, a small supersonic wind tunnel is designed and built to study the flow characteristics of a supersonic impulse turbine. The flow is visualized by means of a single pass Schlieren system. The supersonic cascade with 2-dimensional supersonic nozzle was tested over a wide range of pressure ratio. Highly complicated flow patterns including shocks, nozzle-cascade interaction and shock boundary layer interactions are observed.

  • PDF

Effects of momentum ratio and mixture ratio on combustion efficiency in liquid rocket engine (액체로켓에서의 운동량비와 혼합비가 연소성능에 미치는 영향)

  • Han, J.S.;Kim, S.J.;Kim, S.G.;Kim, Y.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.38-43
    • /
    • 1999
  • An experimental study was carried out, in order to set up the procedure for evaluation of hot fire test, to investigate the effect of mixture on combustion performance and combustion stability , and to determine the optimum design condition for designing the liquid rocket engine. $HNO_3$/Kerosene uni-element liquid rocket engine(thrust 24 $\iota{b}_f$, chamber pressure 200 psia) using impinging streams doublet injector was designed, and ground hot-fire test was carried out. To prevent or reduce the hard start during ignition period, two step ignition method was used. This was accomplished by maintaining about 25% of the designed operating pressure doting transient period, then chamber pressure was built up to the designed operating pressure. Maximum combustion efficiency was at O/F ratio 3.6, and combustion efficiency is decreased with increasing momentum ratio.

  • PDF

Filtration-induced pressure evolution in permeation grouting

  • Zhou, Zilong;Zang, Haizhi;Wang, Shanyong;Cai, Xin;Du, Xueming
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.571-583
    • /
    • 2020
  • Permeation grouting is of great significance for consolidating geo-materials without disturbing the original geo-structure. To dip into the filtration-induced pressure increment that dominates the grout penetration in permeation grouting, nonlinear filtration coefficients embedded in a convection-filtration model were proposed, in which the volume of cement particles in grout and the deposited particles of skeleton were considered. An experiment was designed to determine the filtration coefficients and verify the model. The filtration coefficients deduced from experimental data were used in simulation, and the modelling results matched well with the experimental ones. The pressure drop revealed in experiments and captured in modelling demonstrated that the surge of inflow pressure lagged behind the stoppage of flow channels. In addition, both the consideration of the particles loss in liquid grout and the number of filtrated particles on pore walls presented an ideal trend in filtration rate, in which the filtration rate first rose rapidly and then reached to a steady plateau. Finally, this observed pressure drop was extended to the grouting design which alters the water to cement (W/C) ratio so as to alleviate the filtration effect. This study offers a novel insight into the filtration behaviour and has a practical meaning to extend penetration distance.

Evaluation of Dynamic Characteristics of Slipmeters with Force Platform (하중판을 이용한 미끄러짐 측정기의 동력학적 특성 평가)

  • Kim, Jung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.1-8
    • /
    • 2012
  • The purpose of this study were to evaluate the dynamic characteristics of the portable slipmeters with respect to actual slipping and to compare their output with those of force platform. The selected slipmeters were commonly used devices for slipperiness measurement in situ floors. Their output quantity represented force (BOT-3000), loss of energy(British pendulum striker) and angle of inclination(English XL). The validity of these devices was studied with respect to actual slipping using a force platform. The precision of these devices was also evaluated with force platform. Based on dynamics of human subject behavior when slipping during normal walking, the all devices tested in this study showed poor performances: low built up ratio, low normal pressure, and long contact time prior to slip. Nevertheless, their results reasonably correlated with those calculated from the ground reaction forces generated by the operation of the selected slipmeters on the force platform although the absolute values of COF from these three devices could be quite different. Also the results showed good repeatability under the some test conditions.

Design and Development of Micro Combustor (I) - Combustion Characteristics in Scale-Downed Combustor - (미세 연소기 개발(I) - 소형 연소기 환경에서의 연소 특성 -)

  • Lee, Dae-Hun;Choe, Gwon-Hyeong;Gwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.74-81
    • /
    • 2002
  • Combustion phenomena in a sub-millimeter scale combustor have been investigated. To evaluate scale effect on flame propagation characteristics, a cylindrical combustion chamber with variable depth was built in-house. The combustor was charged with premixed gas of hydrogen and air and ignited electronically. A piezo electric pressure transducer recorded transient pressure after the ignition. Measurements were made at different test conditions specified with chamber depth and initial pressure as parameters. Visual observation was made through a quartz glass window on top side of the combustion chamber using high speed digital video camera. From the pressure data, available work was estimated and compared with energy input required for stable ignition. The preliminary results suggested that the net thermal energy release is sufficient to generate power and enables a combustor of the size in the present study to be used as the energy source of a micro power devices .

Deformation of the PDMS Membrane for a Liquid Lens Under Hydraulic Pressure

  • Gu, Haipeng;Gan, Zihao;Hong, Huajie;He, Keyan
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.391-401
    • /
    • 2021
  • In the present study, a hyperelastic constitutive model is built by complying with a simplified hyperelastic strain energy function, which yields the numerical solution for a deformed polydimethylsiloxane (PDMS) membrane in the case of axisymmetric hydraulic pressure. Moreover, a nonlinear equilibrium model is deduced to accurately express the deformation of the membrane, laying a basis for precise analysis of the optical transfer function. Comparison to experimental and simulated data suggests that the model is capable of accurately characterizing the deformation behavior of the membrane. Furthermore, the stretch ratio derived from the model applies to the geometrical optimization of the deformed membrane.

Characteristics of Thermoacoustic Oscillation in Ducted Flame Burner (관형 연소기의 열음향학적 특성에 관한 연구)

  • 조상연;이수갑
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.621-626
    • /
    • 1997
  • Combustion instability is a common phenomenon in a ducted flame burner and is known as accompanying low frequency oscillation. This is due to the interaction between unsteady heat release rate and sound pressure field, that is, thermoacoustic feedback. In Rayleigh criterion, combustion instability is triggered when the heat additions is in phase with acoustic oscillation. A Rijke type burner with a pre-mixed flame is built for investigating the effect of Reynolds number and equivalence ratio on thermoacoustic oscillation. In addition, the effect of wall temperature is presented. The results suggest that the frequency of max. oscillation is dependent on Reynolds number and equivalence ratio whereas its magnitude is not a strong function of these two parameters. On the other hand, the wall temperature distribution has much strong effects on the oscillation, even creates different mode of acoustic resonance.

  • PDF

Characteristics of thermoacoustic oscillation in ducted flame burner (관형 연소기의 열 음향학적 특성에 관한 실험적 연구)

  • 조상연;이수갑
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.985-991
    • /
    • 1997
  • Combustion instability is a common phenomenon in a ducted flame burner and is known as accompanying low frequency oscillation. This is due to the interaction between unsteady heat release rate and sound pressure field, that is, thermoacoustic feedback. In Rayleigh criterion, combustion instability is triggered when the heat addition is in phase with acoustic oscillation. A Rijke type burner with a pre-mixed flame is built for investigating the effect of Reynolds number and equivalence ratio on thermoacoustic oscillation. The results suggest that the frequency of max, oscillation is dependent on Reynolds number and equivalence ratio whereas its magnitude is not a strong function of these two parameters.

  • PDF

Mini PC control system for BYG type water supply units (BYG형 급수기의 MINI PC 제어 시스템)

  • 박용규;강영모
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1167-1171
    • /
    • 1993
  • A highly efficient hydropneumatic water supply system type BGY is designed and built in accordance with ISO standard. The technical features of BYG type pump unit can be summarized as follows: - reduce hydropneumatic tank capacity at the ratio of 1/10 - 1/30 compared with conventional method. - ISO standard pumps can be used. - the development of highly efficient water supply system type BYG is based on long-term experiences with the proven constant pressure water supply technique which minimize pressure fluctuation, rapid pilsation, etc. The text contains the operation principle of BYG type water supply system, introduction of closed cycle control process focused on Mini PC and experimental results of type BYG-IVS-90x45.

  • PDF

An Experimental Study on the Flow Characteristics ofa Supersonic Turbine Cascade as Pressure Ratio

  • Cho, Jong-Jae;Jeong, Soo-In;Kim, Kui-Soon;Lee, Eun-Seok
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.2
    • /
    • pp.9-17
    • /
    • 2004
  • In this paper, a small supersonic wind tunnel was designed and built to studythe flow characteristics of a supersonic impulse turbine cascade by experiment. Theflow was visualized by means of a single pass Schlieren system. The supersoniccascade with 3-dimensional supersonic nozzle was tested over a wide range ofpressure ratio. Highly complicated flow patterns including shocks, nozzle-cascadeinteraction and shock boundary layer interactions were observed.