• Title/Summary/Keyword: Buildings Energy Consumption

Search Result 522, Processing Time 0.034 seconds

A Study on the Comparison for Energy Consumption Characteristics between G-SEED certified and non-certified Office Buildings in Korea (G-SEED 인증 건축물과 비인증 건축물의 에너지 소비량 특성에 관한 연구 : 업무시설을 대상으로)

  • Kim, Jong-Hyun;Kim, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.33-43
    • /
    • 2019
  • Considerable efforts have been made to reduce greenhouse gas emission around the world to cope with climate change. The government is implementing G-SEED certification to promote energy efficient building design. This study aims to verify the effectiveness of the G-SEED certification system by analyzing the actual energy use of certified and non-certified office buildings. For this purpose, the energy consumption of 135 certified and 142 non-certified office buildings was analyzed according to the seasonal characteristics, building size and number of floors, approval year, and certification grade. The energy saving effects of certified buildings was about 50% higher than that of non-certified buildings. The seasonal energy consumption of buildings is closely related to the heating degree-days. The energy consumption of certified and non-certified buildings decreases with increasing approval year. On the other hand, the energy consumption according to building size and certification grade is not related. This study provides meaningful basic data of G-SEED certification system for future improvement. As the building energy performance standards are strengthened over the years, it is necessary to make the individual score of G-SEED certified projects open to the public to configure the factors of energy efficiency.

The Influence of Unit Plan Shapes to the Energy Efficiency of Collective Housing Simulated by ECO2 Software (ECO2 프로그램을 이용한 공동주택의 단위세대 평면 형태에 따른 에너지 효율 평가)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: Various policies to reduce the energy consumption have been carried out to save Earth environment against global warming and environmental pollution in many countries. Energy consumption of buildings in Korea has reached 24% of total energy consumption, and energy consumption of apartment has been continuously increasing. Therefore, Korea government has executed building energy efficiency rating certification system to control energy consumption of buildings. Method: This study was conducted to evaluate the energy performance of apartment unit plans according to the increasement of front width of unit plans, and tried to present the basic data to design more energy conscious unit plans for apartments. For the study, three shapes of unit plans -the 2Bay, 3Bay and 4bay unit- were selected for imput models. They were simulated using ECO2 software to assess building energy efficiency rating certification in Korea. Result: According to the results, in cases that balcony windows were not installed, the primary energy consumption of the 3Bay and 4Bay units were less than 2Bay unit, respectively, 0.1% and 2,5%. The primary energy consumption of the 3Bay and 4Bay units, in cases that balcony windows were installed, was less than 2Bay unit, respectively, 1.7% and 3.2%.

The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings (Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석)

  • Hwang, Woo-Jin;Kim, Kyo-Joon;Choi, Won-Ki
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF

Prediction of City-Scale Building Energy and Emissions: Toward Sustainable Cities

  • KIM, Dong-Soo;Srinivasan, Ravi S.
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.723-727
    • /
    • 2015
  • Building energy use estimation relies on building characteristics, its energy systems, occupants, and weather. Energy estimation of new buildings is considerably an easy task when compared to modeling existing buildings as they require calibration with actual data. Particularly, when energy estimation of existing building stock is warranted at a city-scale, the problem is exacerbated owing to lack of construction drawings and other engineering specifications. However, as collection of buildings and other infrastructure constitute cities, such predictions are a necessary component of developing and maintaining sustainable cities. This paper uses Artificial Neural Network techniques to predict electricity consumption for residential buildings situated in the City of Gainesville, Florida. With the use of 32,813 samples of data vectors that comprise of building floor area, built year, number of stories, and range of monthly energy consumption, this paper extends the prediction to environmental impact assessment of electricity usage at the urban-scale. Among others, one of the applications of the proposed model discussed in this paper is the study of urban scale Life Cycle Assessment, and other decisions related to creating sustainable cities.

  • PDF

Monthly Heating Energy Needs Analysis According to ISO 13790 and ISO 52016 (ISO 13790과 ISO 52016에 의한 월별 난방에너지 소요량 분석)

  • Zo, Chung-Hoon;Yun, Geun-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.5
    • /
    • pp.11-28
    • /
    • 2019
  • Governments are increasing energy efficiency in buildings through various policies to reduce building energy consumption. In 2002, the European Union adopted a building energy performance guideline to set minimum efficiency standards for residential and commercial buildings. Starting in 2020, all EU member states should ensure that all buildings are Near-Zero Energy Buildings (NZEB). In Korea, the government issued a zero-energy certification system. Since 2020, public buildings are required to cover energy consumption with the energy produced in buildings. As the demand for building energy simulation has increased to increase the energy efficiency of these buildings, the International Standard Organization (ISO) has created a standard for calculating building energy requirements called ISO 13790. This standard was revised to ISO 52016 in 2017. In this research, ISO 13790, which calculates the energy needs of existing buildings, and ISO 52016, which replaces them, are compared and analyzed, and applied to the calculation of heating energy needs of buildings. For models without thermal zoning(Case A), the difference in annual heating energy needs calculated from each criterion is $1.08kWh/m^2$, which is about 2% higher in ISO 52016. In the case of the thermal zoning model(Case B), the difference in annual heating energy needs calculated by each standard was $0.97kWh/m^2$, which was about 2% higher than ISO 52016. The heating energy needs model without thermal zoning has a higher energy needs than the heating energy needs model with thermal zoning. It is about 16% energy at $8.58kWh/m^2$ for ISO 13790 and $8.69kWh/m^2$ for ISO 52016.

Typological Evolution of High-Rise Buildings in Terms of Thermodynamics and Energy Formation

  • Li, Linxue;Shen, Xiaofei;Qian, Ren
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.2
    • /
    • pp.127-133
    • /
    • 2015
  • High-rise buildings are frequently criticized for their absolutely artificial environments and high energy consumption. This paper tries to present an alternative approach to, and new prototypes for high-rise buildings through dialectic reconsideration of the responsive relation between high-rise buildings and environmental elements, in terms of thermodynamics and energy formation.

An Analysis of the Building Energy Demand of Rural House and Passive type House - An Analysis of the Airtightness and Window system Performance according to using PHPP (기존 농촌주택과 패시브형 주택의 에너지 요구량 비교분석 - PHPP분석을 통한 주택의 기밀성 및 창호성능 분석을 중심으로)

  • Cho, Kyung-Min;Lee, Tae-Goo;Kim, Joo-Soo
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2011
  • Due to global warming issues caused by climate changes which are internationally being highlighted, recently, there are lots of efforts under way to reduce energy consumption in various fields. Currently, 25 percent of energy consumption in Korea are being generated from buildings and especially, nearly 54 percent of them are being consumed by households. This study, therefore, aims to consider energy consumption status in the existing rural houses and analyze structure system performance, window system performance and air-permeability of domestic passive-type buildings using PHPP which is an analysis program of building energy to improve energy consumption problems in rural areas. Then, energy reduction plans in rural houses were proposed, by comparing and analyzing energy reduction of the existing rural houses, based on these data.

A Measurement and an Analysis of Heating and DHW Energy Consumption in Apartment Buildings with individual Heating Systems (개별난방 공동주택의 난방 및 급탕 에너지사용량 계측 및 특성 분석)

  • Lee, Soo-Jin;Jin, Hye-Sun;Kim, Sung-Im;Lim, Su-hyun;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.6
    • /
    • pp.15-22
    • /
    • 2018
  • The purpose of this study was to suggest specific evaluation data for heating and DHW energy consumption characteristics through analyzing energy consumption measurement data of gas boiler in Apartment Buildings with individual heating systems. To do this, it was measured both gas flow and electricity for heating and DHW respectively, and then it was analyzed not only characteristics according to energy sources; gas and electricity, but also the effect of various factors on heating and DHW energy consumption. The result of this study were as follows. It was developed the electric energy estimation model of a gas boiler through analysis on patterns by energy sources. And the effective factors for heating and DHW energy consumption were demonstrated as follows: the area for exclusive use, the number of auxiliary heating equipments, the number of occupants, and the number of sanitary fixtures.

A Study on Heating Energy Monitoring of a Rural Detached House Applying Passive House Design Components (패시브 하우스 디자인 요소를 적용한 농촌지역 단독주거건물의 난방에너지 모니터링 연구)

  • Cho, Kyung-Min;Lee, Tae-Goo;Han, Young-Hae
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.39-46
    • /
    • 2013
  • Recently, the field of construction is putting a variety of effort into reducing CO2, since global warming is being accelerated due to climate changes and the increase of greenhouse gas. For reduction of CO2 in the field of construction, it is required to make plans to cut down heating energy of buildings and especially, it is urgently needed to cut down energy of residential buildings in rural area where occupies the majority of consumption of petroleum-based energy sources. Therefore, this research compared and analyzed the actual energy consumption, by evaluating energy performance of a detached house applying passive house design components for reduction of energy. As the result, energy consumption showed remarkable differences, according to the operation of a heat recovery ventilation unit which is one of passive house design components, and building energy consumption displayed remarkable differences, too, depending on the difference of airtightness performance during building energy simulation conducted in process of design. Based on these results, the importance of airtightness performance of passive house was verified. The result of the actual measurement of energy consumption demonstrated that LNG was most economical amongst several heat resources yielded, on the basis of LPG source energy consumption measured within a certain period of time, and it was followed by kerosene. LPG was analyzed to have a low economic efficiency, when used for heating.

A Study on Improvement and Effect of Carbon Point Program for Residential Buildings in Daegu (대구광역시 주거 건축물의 이산화탄소 배출 감축을 위한 탄소포인트제의 효과 및 개선방향에 관한 연구)

  • Yeo, Myung-Kil;Jeon, Gyu-Yeob;Hong, Won-Hwa;Cho, Woong-Ho
    • Journal of the Korean housing association
    • /
    • v.23 no.4
    • /
    • pp.11-18
    • /
    • 2012
  • The amount of energy consumption in the buildings is approximately 20% of domestic energy consumption. The Carbon Point Program have been published on reduction of greenhouse gas emission in buildings under the paradigm of 'Low Carbon Green Growth'. This study focuses on the effect of 'Carbon Point Program' for residential buildings in Daegu. The amount of electricity and waterwork consumption and information of households were investigated to analyse the effect of carbon point program. The samples are situated in Deagu and are apartment in Bukgu and Suseonggu. The $CO_2$ emission is analysed by factors of energy resource and household organization between before participating and after participating in Carbon Point Program. The participation type has a difference of voluntary participation in Suseonggu and passive participation in Bukgu. Based on this investigation, average amount of $CO_2$ emission was reduced from voluntary participation households but all of them did not. To promote the effect of Carbon Point Program, this study proposes that needing the plans to raise will and activity of reducing carbon and to help participation which have disadvantage against achieving reduction.