• Title/Summary/Keyword: Building type

Search Result 3,431, Processing Time 0.031 seconds

A Study on the Deterioration Patterns of Building Components in the Rental Apartment Housing (임대공동주택 구성재의 열화도 패턴에 관한 연구)

  • Lee Kang-Hee
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.65-72
    • /
    • 2006
  • Most of buildings have been deteriorated with time-elapse by reflection of the building location, material, environmental circumstances and so on. The performance would go down and be demolished if anything could not be done after constructed. The maintenance should be required to preserve a decent living condition or improve a inferior condition by various plans and practices. The maintenance plan needs various data such as a repair scope, a repair time, a forecasted cost, a plan of management and so forth. Among the above required data for planning the maintenance, the deterioration characteristics of the building components would be first analyzed. The deterioration pattern would be a key role to affect and make a maintenance plan. In this paper, it aimed at classifying the deterioration patterns of building components. A deterioration pattern would be analyzed between the cumulative repair cost and time-elapse and modeled with these relations. A deterioration patterns are classified into 4 types-a accelerated type, a straight type, a temporary type and a slowly type. As a result of this research, a accelerated type includes window, window frame, general paintings, general water proofing in building components. A straight type includes the lacquer paintings, furnishings in building components and water supply pipe, boiler, sanitaries in mechanical facilities and lighting in electric facilities. Based on these research results, further study should be conducted to include any other components and an estimating model.

Basic study for development of bottom-up infill module for high rise building (고층 건축물을 위한 bottom-up Infill module 개발 기초 연구)

  • Sung, Soojin;Lim, Chaeyeon;Na, Youngju;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.164-165
    • /
    • 2015
  • Modular construction technique is an adaptation of factory-based mass production concept in ordinary manufacturing industries to construction industry and it assumes that panels, units, etc. are fabricated in factories and assembled in construction sites. Given its structural limitations, modular construction technique is primarily used in low-story buildings whose maximum height is usually five stories, but researchers are actively studying possible adaptation of modular construction technique to high-rise building designs these days as in the case of infill-type modular construction design. Infill-type modular construction technique, most frequently used in high-rise building construction projects, completes frame construction first in reinforced concrete structures and fills unit modules in such structures. However, infill-type modular construction technique leads to longer construction schedule accompanying increase in construction cost, cost overrun due to additional of temporary work, and possible damage to units in the wake of facility construction. Accordingly, this study is performed as a basic study for the development of bottom-up infill-type modular construction technique intended to construct structural frames and fill in units sequentially in a bid to address such drawbacks of current infill-type modular construction technique.

  • PDF

A Study on the Spatial Configuration Characteristics of the Apartment Building Type based on the Space Syntax Analysis (공간구문론 분석에 의한 아파트 주동형식별 공간배치 특성에 관한 연구)

  • 박몽섭;박찬돈;하재명
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.185-194
    • /
    • 2004
  • This paper deals with the spatial configuration of the unit floor plan based on the apartment building type. It is generally agreed that various apartment building types were organized by diverse apartment unit floor plan. The reason behind this diversity, apartment unit plan are affected by the environmental condition and the diverse spatial composition of the unit floor plan. Apartment building types were classified by the similarity of the justified-graph type. This types classified into two category; One core type which were classified by the shape of the core, and multiple core type which were compounded by more than two core. These categories divided into 5 types, and 2 types. Each types were compared in view of the mean depth, relative asymmetry, integration value. Consequently, these types could be classified in the number of the unit floor plan. It is profitable to 3 unit types which was analyzed in view of an indicator of the spatial configuration. Therefore, 3 unit types is favorable to the composition of the apartment building types.

An Analysis of Heating and Cooling Energy Cost according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 비용 분석)

  • Roh, Ji-Woon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.96-105
    • /
    • 2013
  • This study aims to investigate the energy performance of apartment in respect of complex design, building type and generation house layout and finally to produce the guide line for energy saving design. To grasp the present condition and problem about this subject, apartment building types were examined and representative types were extracted. Considering azimuth angle, private area, and generation number, building type of the subject apartment was classified in detail, energy simulation was conducted, and the effect to energy cost was compared. In the research, using VE energy simulation program, the heating and cooling load were calculated and converted to energy cost. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Energy cost is compared according to several azimuth in plank '一' type apartment. As the results, calculated gas cost is the best in $49^{\circ}$, but total cost is in $-31^{\circ}$. 2) Apartment buildings of tower types are compared, it is resulted that 'Y' type (azimuth $-7^{\circ}$, $-20^{\circ}$) is the best in gas cost, but the total cost is worst because of high cooling load.

A Study on the Integrated Prefab Building Materials Depending on the Cooling Type of PV Mocdule Backside (태양전지모듈 후면의 냉각조건에 따른 조립식 건축자재와 일체화에 관한 연구)

  • Yi So-Mi;Lee Yong-Ho;Hong Sung-Min
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.9-15
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, the purpose of this research is to integrated prefab building materials depending on the cooling type of PV modules. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module temperature. From the basis of these results on the correlation of temperature and irradiation were obtained.

  • PDF

A Study on the Integrated Prefab Building Materials Depending on the Cooling Type of PV Module Backside (태양전지모듈 후면의 냉각조건에 따른 조립식 건축자재와 일체화에 관한 연구)

  • Yi, So-Mi;Lee, Yong-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.138-141
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre-manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, the purpose of this research is to integrated prefab building materials depending on the cooling type of PV modules. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module temperature. From the basis of these results on the correlation of temperature and irradiation were obtained.

  • PDF

The Plan Types of Excavation Remains during the Mid to Late Joseon Period around Jong-ro in Seoul (서울 종로 주변 발굴유적에서 보이는 조선 중·후기 건물지의 평면형식)

  • Bae, Chang-Hyun;Jeon, BongHee;Huh, Yoojin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.79-88
    • /
    • 2018
  • The purpose of this study is to analyze the plan type of excavation remains during the Mid to Late Joseon period around Jong-ro area in Seoul. 523 building remains were selected in accordance with plan type could identified through the excavation investigation report. Among these, 276 building remains were verified to the $15-16^{th}$, 145 and 102 building were verified to the 17-18th and the $19^{th}$ century. By classifying excavation remains, four dominant plan type of the each century came out. First, -shape was the most common plan type took nearly 50 percent. In a considerable proportion of cases, this plan type seems an annex of main building. However, -shape plan type also seemed to be used for main building in some cases. ㄱ and ㄷshape plan type took the second and the third. In most cases, these types seemed typical plan used for a main housing building. For the last, ㅁshape plan type identified the most unusual. This plan type merely took under five percent but, these cases are meaningful because it shows the plan alteration from ㄷshape to ㅁshape plan type. Existence proportion between each plan types of the $15-16^{th}$ century were continued to the $18-19^{th}$century without small changes between -and ㄱ types in $17-18^h$ century. By examining selected excavation remains, installing front Toi space on ㄱ, ㄷ and ㅁshape plan type stand out clearly compared with -shape plan type. From this tendency, it could be considered that plan type became a significant factor influenced installing Toi space. Similar to periodical tendency of plan type was not changed dramatically, the rate of installing Toi space in the $15-16^{th}$ century was not changed much until the $18-19^{th}$ century. It also shows the close relation between plan type and installing Toi space. In some excavation remains, floor type in the $15-16^{th}$ century also verified. There are some points of similarities on installing typical location of On-dol, Ma-ru and Bu-eok in these excavation remains with later period housing type such as Ut-Bang-Gguk-Oem-Jib and Ddeul-Jib.

Characteristics of the influence of defect types and period of occurrence according to the type of tile work in an apartment house (공동주택 내 타일 공종에 따른 하자 유형과 발생기간의 영향 특성)

  • Pyeon, Su-Jeong;Kim, Gyu-Yong;Choi, Byung-Cheol;Kim, Moon-Gyu;Gill, Min-Woo;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.67-68
    • /
    • 2022
  • The area inside the apartment building where tiles are installed is applied as a finishing material for walls and floors, including exterior walls, balconies, hallways, bathrooms, and kitchens. As it is constructed in various spaces, differences in the type and period of occurrence of tile defects may appear, which is caused by heterogeneous characteristics between materials and external causes. Therefore, in this study, two-way ANOVA was used to figure out the relationship between the defect occurrence type and the period depending on the type of tile construction in the apartment building.

  • PDF

Analysis of the Condenser Stack Effect in a High-Rise Apartment Building (고층 아파트에서 응축기 적층문제 분석)

  • 최석호;이관수;김인규;이동혁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.796-803
    • /
    • 2004
  • The stack effect of a new type condenser installed in a high-rise apartment building was studied numerically A sirocco fan is introduced to the new type condenser instead of an axial flow In. The new type condenser intakes the cold air through the lower inlet and exhausts the hot air through the upper outlet. The effects of the building height and frontal wind on the performance of an air-conditioner were analyzed. The performance of an air-conditioner was evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). the hot air was exhausted by the new type condenser at an angle of 50$^{\circ}$ from the outer wall of the building. If there was no draft, the new type condenser installed in the high-rise apartment building had a good performance and its performance on each floor is not influenced by the stack effect. It is shown that the efficiency of the air-conditioner installed in several floors below the top floor decreased when the frontal wind velocity was greater than 8 m/s.

A Study on the Combustion Characteristic of Building Materials (건축용 내장재의 연소 특성에 관한 연구)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Kim, Jin-Pyo;Park, Jong-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.23-28
    • /
    • 2011
  • This paper studied combustion characteristics of the building materials such as polyurethane-foam, sponge type sound-absorbing materials and styrofoam. To estimate of the combustion characteristics, we carried out combustion experiment of the building materials. And then to evaluate the suitability of the building materials, we measured heat release rate(HRR) and smoke density(Ds) of polyurethane-foam, sponge type sound-absorbing materials and styrofoam using by a cone-calorimeter. From the combustion experimental results, the general type sound-absorbing materials (GSAM) and styrofoam were rapid burned simultaneously with ignition and the incombustibility type sound-absorbing materials(ISAM) and polyurethane-foam had all gone out simultaneously with ignition. Measured results of HRR and Ds were not satisfied KS F ISO 5660-1 and IMO FTP Code, from the results, the polyurethane-foam, the sponge type sound-absorbing material and the styrofoam were ill-suited for using building interior materials.