• Title/Summary/Keyword: Building regulation

Search Result 385, Processing Time 0.029 seconds

The Plan of Improvement for the Law and Regulation on the Activation of Perpendicular Greening With Containers -With Apartment Simple planter- (화단형 입면녹화의 활성화를 위한 법적·제도적 개선방안 - 공동주택 간이화단을 중심으로 -)

  • Kim, Sun-Hae
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.41-47
    • /
    • 2004
  • This study is to improve plan for the law and regulation systems on the perpendicular greening with containers to improve urban environment. The supports backed by laws and regulations are imperative for the activation of building greening. Although some local administrations in Korea try to lead perpendicular greening on building by means of Green Building certification system and so on, greening policies and managements are not pushed forward with consistency. Therefore building greening should be admitted to be a substitute green tract of land. The positive construction and management of greenzone should be accomplished as well. Devices, so to speak, which put greening under an obligation or authorize it as legal landscape area should be made rather than recommendations to make greenzone through current incentive systems. Positive perpendicular greening on building can be achieved by supplementing the law and regulation and incentive system about simplified planter. If planting and managing of simplified planter are continually entrusted to residents, even vertical landscapes will be affected by illegal diversion and negligence in result. Therefore, supports from governments and local administrations are needed.

A Study on Present Condition and Adjustment of the Minmium Height Regulation District in Busan Metropolitan City (부산시 최저고도지구 실태 및 기준조정에 관한 연구)

  • Lee, Dong-Hyun;Baek, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2008
  • The Purpose of this study is to find the adjustment of the minimum height regulation district in Busan metropolitan city. For this purpose, data of buildings in the minimum height regulation district are collected and analysed. Especially, detailed data of buildings in CBD are analysed. The results of this study provide that CBD's average building height is the fourth floor and the ratio that a building less than the fourth floor holds in total building is 51%. In the case of central area, CBD's building height should be maintained and it is necessary to make the policy that reinforce limited height for the high land use and landscape management. Based on these findings this study suggests that the limit building height should put it up more than the seventh floor.

  • PDF

A Comparison Study on the System of the cultural properties law for Fire Protection in Korea and Japan (한국과 일본의 제도적 문화재보호에 대한 비교연구)

  • Yun, Yoo-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo;Lee, Jae-Young;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.57-60
    • /
    • 2008
  • A comparative study on the prevention regulation of historical heritage between Korea and Japan. Every years fire accident to historical building is increasing such as Daewoongjun, Naksansa, Namdaemun and so on. The aim of this comparative study is to investigate and compare the prevention regulation in the side of fire safety of historical building between Korea and Japan. This study focus on the background of development and exchange of Fire safety law in Japan because of same condition, building material and prevention regulation.

  • PDF

Fire Regulation for Building Material of Organic Matter (유기물 건축내장재에 대한 화재법규)

  • Yoon, Kwan-Sun;Choi, Keun-Young
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.136-142
    • /
    • 2007
  • Due to the construction technique (or the construction culture) growth in and out of Korea, newly-developed products have been continuously released. Furthermore, all legislation and regulation that the World follows are gradually becoming unified. (e.g. FTA(Free Trade Agreement) with the United States was contracted, and inevitable FTA contraction with EU and China ), For this reason, it is considered that Korean fire regulation on building interior materials needs to be reviewed and compared with that of international standard so that it becomes legitimate and reasonable one. Especially, this reference is going to make a description of building interior materials' Flame retardant performance standard.

  • PDF

A Study on the Height Limitation of a Building in Building Law - Focusing on the Standard of the Ground Level Calculation - (건축법(建築法)에서의 건축물(建築物) 높이제한규정(制限規定) - 지표면산정기준(地表面算定基準)을 중심(中心)으로 -)

  • Kim, Soo-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.29-38
    • /
    • 2003
  • The articles on building height limitation are very important to form buildings to be. The application of the articles is based on the surface of the building site ground, that is, the definite judgment of ground level should ensure the correctness of building height limitation. This study surveyed the recognition degree of practitioners about the building height limitation regulations by questionnaires, and analyzed its results and compared them to related building laws and letter of reply from the office to practitioners' inquiry on related regulation. The study summarized the results as follows; 1. It is not clear to judge the ground level. Especially in cases of pilotis structure, there would be various interpretations to define its ground level. 2. According to present building regulations, the site would be confused to define by practitioners whether it is stiff or plain. 3. In case of regulation of a right to enjoy sunshine, it is hard to calculate the average horizontal level(ground level) with neighboring sites. 4. If there were a manual with illustrations for judging and calculating the ground level of various cases, civil petitions would be reduced.

  • PDF

A Study on the Chemical Admixture According to Target Slump Value by Crushed Sand Replacement Rate (부순모래 치환율별 목표슬럼프 값 고정에 따른 화학혼화제의 특성에 관한 연구)

  • Ryu, Hyun-Gi;Cho, Myeong-Ken
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.4
    • /
    • pp.87-93
    • /
    • 2008
  • With an increased use of alternative aggregate due to exhaustion of quality aggregate resources, the amount of used crushed aggregates have been increased and as a result, development of admixture materials has also been improved and its amount of use is increasing from day to day in order to secure quality in concrete. Accordingly, the purpose of this study is to make concrete of good quality by using chemical admixture developed in this study by replacement rate of fine aggregate. At first, susceptibility, compressive strength ratio and length change ratio in both fresh and hardened concrete were evaluated according to corresponding regulation. As for high performance related regulation, APC NO.3 and PC series were going to rule, and as for AE agent regulation, replacement ratio of fine aggregate of high performance chemical admixture was 10:0 and other chemical admixture met quality regulation for AE agent.

The basic study on the improvement of the evacuation regulation related with the elderly facilities (노인복지시설 피난관련 규정 개선에 관한 기초 연구)

  • Hwang, Eun-Kyoung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.329-332
    • /
    • 2008
  • When the fire takes place inside the building, it is the most important for the people who are inside the building to escape to the safe place. Specially, the elder are the most serious victims because of their short of fire confrontation ability. This study will analysis the evacuation regulation for the elderly facilities. and on the basis of this, this research proposes the basic data for evacuation re-regulation for the elderly facilities through the actual condition investigation of the elderly facilities and interviews with its supervisors.

  • PDF

The Establishing of the Self-regulation System for Quality and Safety Management (현장(現場) 자율(自律) 품질안전관리(品質安全管理) 시스템 구축(構築))

  • Baik, In-Whee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.81-87
    • /
    • 2007
  • PMIS (Project Management Information System) has been applied in the R4-PROJECT This construction project has been controlled and managed by PMIS for the whole process of project. Moreover, this PMIS is updated to the Self-regulation System for Quality and Safety Management which is integrated and developed from PMIS in R4-PROJECT. So, The Self-regulation System for Quality and Safety Management has been delivering effective communication and information distribution with various stakeholders related to project and also brought the achievement of efficient construction management. As the system is successfully utilize, the satisfaction of costumer request and the performance of no accident for 550 million hours could be attained.

  • PDF

A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses (다중이용업소 실내마감재료 사용기준에 관한 연구)

  • Kim, Yong-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Building Envelope (외피 열성능에 따른 건물에너지효율등급 분석 연구)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Kim, Ji-Yeon;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.59-64
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.