• Title/Summary/Keyword: Building materials

Search Result 3,252, Processing Time 0.031 seconds

Role of Music in Therapist - Client Relationship (치료사-내담자 관계에서 음악의 역할에 대한 사례 연구)

  • Rhee, Hye Joo
    • Journal of Music and Human Behavior
    • /
    • v.3 no.2
    • /
    • pp.29-44
    • /
    • 2006
  • Trust and understanding relationship promoted between a therapist and a client is the basic building block to successful recovery. Its importance is not only pertaining to the music therapy but also to counseling and psychological therapy. Because of its gnificance, broad spectrum of research has been conducted for quite a long time. Historically, researches have been focused on therapists or client's chological variables rather than emotional effects on each other that occur during the therapy session. Recently researchers turned their attention to emotional relationship between a therapist and a client. With recent advances in the field of music and psychological therapy, subsequent study has been conducted to investigate the role that music plays in the therapeutic relationship. For this research, eleven music therapy sessions were conducted for the adult females who are alcoholics. The first three sessions were of group therapy. Fourth to eleventh therapy session was done individually. Throughout the research case-by-case study has been conducted on the basis of the analysis of video and audio taped materials. Analysis depends heavily on its reference from the Amir's music research of 1990, which used Ferrara's seven phases of phenomenological study. Especially, verbal and nonverbal communications were closely analyzed in musical perspective. Research revealed that music and musical instruments act as a mediator between a therapist and a client. By doing so, it protects a therapist from unnecessary negative emotional displacements of a client and creates mutual reliability between a therapist and a client. Here, research suggests that music and musical instrument play a central role in building relationship between a therapist and a client, and it indicates that it has positive effect on treatment.

A Study of Radon Reduction using Panel-type Activated Carbon (판재형 활성탄을 이용한 라돈 저감 연구)

  • Choi, Il-Hong;Kang, Sang-Sik;Jun, Jae-Hoon;Yang, Seung-Woo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.297-302
    • /
    • 2017
  • Recently, building materials and air purification filters with eco-friendly charcoal are actively studying to reduce the concentration of radon gas in indoor air. In this study, radon reduction performance was assessed by designing and producing new panel-type activated carbon filter that can be handled more efficiently than conventional charcoal filters, which can reduce radon gas. For the fabrication of our panel-type activated carbon filter, first the pressed molding product after mixing activated carbon powder and polyurethane. Then, through diamond cutting, the activated carbon filter of 2 mm, 4 mm and 6 mm thickness were fabricated. To investigate the physical characteristics of the fabricated activated carbon filter, a surface area and flexural strength measurement was performed. In addition, to evaluate the reduction performance of radon gas in indoor, the radon concentration of before and after the filter passes from a constant amount of air flow using three acrylic chambers was measured, respectively. As a result, the surface area of the fabricated activated carbon was approximately $1,008m^2/g$ showing similar value to conventional products. Also, the flexural load was found to have three times higher value than the gypsum board with 435 N. Finally, the radon reduction efficiency from indoor gas improved as the thickness of the activated carbon increases, resulting in an excellent radon removal rate of more than 90 % in the 6 mm thick filter. From the experimental results, the panel-type activated carbon is considered to be available as an eco-friendly building material to reduce radon gas in an enclosed indoor environment.

A Study on the correlation between a streetscape image and a signboard density - Focused on roadside buildings occupation density of signboard in the business area - (가로경관이미지와 간판밀도와의 상관관계에 관한 연구 - 상업지역 연도건물의 간판 점유밀도를 중심으로 -)

  • Kim, Yun-Hee;Rhee, Jae-Won
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.287-296
    • /
    • 2005
  • The street image in a business area is so much affected by Facade that the front side of a roadside building makes. Recently, for the indiscreet and intemperate advertising signboard of the front side of roadside buildings, a streetscape becomes more disordered than before, so now we need to do research about signboards of roadside buildings for a streetscape image. In this research, we focused on a streetscape with difference of occupation density of signboard in the business area via investigation and analysis about occupation density of signboards of the front side of roadside buildings, and we suggested optimum occupation density of signboards for supporting the road image positively. An object of research is the street in the business area that has many pedestrians and active passing zone of cars. We investigated and analyzed how to feel street images on the rate of occupation density of roadside building's signboards of in the chosen street. As a result of using an adjective that we use for estimating street view images for extraction of street images, we could know 2 factors. We named that one is the image of recognition, and the other is the image of feelings. We knew that signboard density of street of heavily recognized images is from 20% to 30% and, signboard density of street of heavily feeling images is from 50% to 60%. We also could know that people feel both images of recognition and images of feeling in specific density, 30 to 50%. Through this result of research, we can suggest Facade on signboard density with the recognition and the feeling and use images of the street view as materials to be more specific and more special.

  • PDF

The Effects of Near Miss and Accident Prevention Activities and the Culture of Patient Safety Management for the Patient Safety (Near Miss 사고 예방 활동과 환자안전관리 문화형성이 환자안전에 미치는 영향)

  • Chang, Ho-Suk;Lee, Gui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.138-144
    • /
    • 2010
  • Purpose: Despite the rapidly changing healthcare environment, healthcare organizations have recognized the importance of patient safety management. But patient safety management has the problem of the lack of participation of members due to the process of focusing on the follow-up service and punishment. The department of nuclear medicine in Uijeongbu St. Mary's Hospital started this research to reduce the near miss and prevent patient safety accidents by both initiating the participatory near-miss-proof activities as an advance management and constructing a system without disadvantages of reporting. In addition, this research aims to establish a differentiated patient safety management system in the department of nuclear medicine. Materials and Methods: 1. Colleting cases of team members' past and present near miss and accidents(First data collection). 2. Quantifying the cases of near miss and accidents after identifying the degree of importance and urgency through surveys(Second data collection). 3. Quantifying cases and indentifying important points of contact through data analysis. 4. Making and standardizing a manual for important points of contact, and initiating participatory activities to prevent errors. 5. Activating web-based community for establishing the report system of near miss. 6. Estimating the result of before and after activities through surveys and focus group interviews. Results: 1) Quantified safety accidents and near miss in the department of nuclear medicine. About 50 near misses a month and one safety accident a year. 2) Establishing improvement measurements based on quantified data. About 11 participatory activities, the improvement of process, a manual for standardization. 3) Creating a system of safety culture and high participation rate of team members. Constructing a report system, making a check list and a slogan for safety culture, and establishing assessment index. 4) Activating communities for sharing the information of cases of near misses and accidents. 5) As the result of activities, the rate of near miss occurrence declined by 50% and the safety accident did not happen. Conclusion: The best service in the department of nuclear medicine is to provide patients with safety-guaranteed high-quality examination and cure. This research started from the question, 'what is the most faithful-to-the-basics way to provide the best service for patients?' and team members' common answer for this question was building a system with participation of all members. Building a system through the participatory improvement activities for preventing near miss and creating safety culture resulted in the 50% decline of near miss occurrence and no accident. This is a meaningful result from the perspective of advance management for patient safety. Moreover, this research paved the way for creating a culture to report and admit near miss or accidents by establishing a report system with no disadvantage of reporting. The system which sticks to the basics is the best service for patients and will form a patient safety culture system, which will lead to the customer satisfaction. Therefore, all members of the department of nuclear medicine will develop a differentiated patient safety culture with stabilizing the established system.

  • PDF

A Study on the Restoration of the Wangheungsa Temple's Wooden Pagoda (왕흥사 목탑의 복원 연구)

  • Kim, Kyeong-Pyo;Sung, Sang-Mo
    • Journal of architectural history
    • /
    • v.19 no.3
    • /
    • pp.7-29
    • /
    • 2010
  • The form of the Wangheungsa Temple's wooden pagoda site is that of the traditional form of the wooden pagodas constructed during the Baekjae Period. Likewise, it is an important ruin for conducting research on the form and type of the wooden pagodas constructed during the Baekjae Period. In particular, the method used for the installation of the central pillar's cornerstone is a new technique. The purpose of this research is to restore the ruin of the Wangheungsa Temple's wooden pagoda of the Baekjae Period that remains at the Wangheungsa Temple's wooden pagoda site. Until now, research conducted on the wooden pagoda took place mostly centered on the Hwangryongsa Temple's wooden pagoda. Meanwhile, the reality concerning Baekjae's wooden pagoda is one in which there were not many parallel cases pertain to the design for restoration. This research paper wants to conduct academic examination of the Wangheungsa Temple's wooden pagoda to organize the intention of design and design process in a simple manner. This research included review of the Baekjae Period's wooden pagoda related ruins and the review of the existing wooden pagoda ruin to analyze the wooden pagoda construction technique of the era. Then, current status of the Wangheungsa Temple's wooden pagoda site is identified to define the characteristics of the wooden pagoda, and to set up the layout format and the measure to estimate the size of the wooden pagoda in order to design each part. Ultimately, techniques and formats used for the restoration of the wooden pagoda were aligned with the wooden pagoda of the Baekjae Period. Basically, conditions that can be traced from the current status of the Wangheungsa Temple site excavation using the primary standards as the standard. Wangheungsa Temple's wooden pagoda was designed into the wooden pagoda of the Baekjae's prosperity phase. The plane was formed into $3{\times}3$ compartments to design into three tier pagoda. The height was decided by factoring in the distance between the East-West corridors, size of the compartment in the middle, and the view that is visible from above the terrace when entering into the waterway. Basically, the origin of the wooden structure format is based on the Goguryeo style, but also the linkage with China's southern regional styles and Japan's ancient wooden pagoda methods was factored in. As for the format of the central pillar, it looks as if the column that was erected after digging the ground was used when setting up the columns in the beginning. During the actual construction work of the wooden pagoda, central pillar looks as if it was erected by setting up the cornerstone on the ground. The reason that the reclaimed part of pillar that use the underground central cornerstone as the support was not utilized, was because the Eccentric Load of the central pillar's cornerstone was factored in the state of the layers of soil piled up one layer at a time that is repeated with the yellow clay and sandy clay and the yellow clay that were formed separately with the $80cm{\times}80cm$ angle at the upper part of the central pillar's cornerstone was factored in as well. Thus, it was presumed that the central pillar was erected in the actual design using the ground style format. It is possible to presume the cases in which the reclaimed part of pillar were used when constructed for the first time, but in which central pillar was installed later on, after the supplementary materials of the underground column is corroded. In this case, however, technique in which soil is piled up one layer at a time to lay down the foundation of a building structure cannot be the method used in that period, and the reclamation cannot fill up using the $80cm{\times}80cm$ angle. Thus, it was presumed that the layers of soil for building structure's foundation was solidified properly on top of the central pillar's cornerstone when the first wooden pagoda construction work was taking place, and that the ground style central pillar was erected on its upper part by placing the cornerstone once again. Wangheungsa Temple's wooden pagoda is significant from the structure development aspect of the Korean wooden pagodas along with the Hwangryongsa Temple's wooden pagoda. Wangheungsa Temple's wooden pagoda construction technique which was developed during the prosperity phase of the Baekjae Period is presumed to have served as a role model for the construction of the Iksan Mireuksa Temple's wooden pagoda and Hwangryongsa Temple's wooden pagoda. With the plan to complement the work further by excavating more, the basic wooden pagoda model was set up for this research. Wangheungsa Temple's wooden pagoda was constructed as at the Baekjae Kingdom wide initiative, and it was the starting point for the construction of superb pagoda using state of the art construction techniques of the era during the Baekjae's prosperous years, amidst the utmost interest of all the Baekjae populace. Starting out from its inherent nature of enshrining Sakyamuni's ashes, it served as the model that represented the unity of all the Baekjae populace and the spirit of the Baekjae people. It interpreted these in the most mature manner on the Korean peninsula at the time.

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

An Analysis of the Difference in Awareness on Visual Landscape Control Elements among the Expert Groups (경관제어요소에 관한 전문가집단 간 인식차이 분석)

  • Cho, You-Kyung;Kong, Eun-Mi;Kim, Young-Ook
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.2
    • /
    • pp.29-39
    • /
    • 2011
  • Recent interests in the quality of urban space have raised awareness on the role and importance of landscape planning. Although laws and guidelines are officially ready to be imposed as for landscape planning, we do not have concrete materials that can be utilized in the course of practices. The aim of this paper in this regard is to disclose the possible difference in awareness on 'visual landscape control elements' among experts engaged with urban space planning. The expert groups are distinguished to three which are for a planning, design and engineering and the survey is made by questionnaires. The results are analyzed through basic technology statistics in SPSS and independent-sample t-test provided. The survey is done by tens of 'control elements' and the result is that specially, group 1 and group 2 in mixed landscape has the most discrepancy in awareness on those elements but relatively, they has less discrepancy in awareness on compare with other groups through all landscape area. In case of artificial landscape and mixed landscape in 'landscape controled area', the result for comparing between G1 and G2 is that there are the most discrepancy in awareness which are 7 control elements. In case of mixed landscape in 'landscape promoted area', there are 4 control elements for discrepancy in awareness between G2 and G3 which is quite different. The control elements which show the most discrepancy in awareness is height, floor space and building to land ratio in order. The shape elements has only discrepancy in awareness for comparing between G1 and G2 of artificial landscape in 'landscape controled area'. In terms of the average evaluation score of the appropriateness of these control elements, G1 seems to appreciate the role of these elements in systematic landscape planning more than the other group does. In other words, relatively low scores are given by G2 as for the overall functionality of visual landscape control elements. The texture, floor space and building of land ratio has low evaluation score for all area and types. It means that it should reverify for appropriateness of performance for landscape planning as visual landscape control elements.

A Study on the Characteristics of Yuyin ShanFang in China Lǐngnán Region (중국 영남지방 여음산방 원림의 특징에 관한 연구)

  • Shi, Shi-Jun;Ahn, Gye-Bog
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.48-57
    • /
    • 2018
  • In this study, we conducted an analysis on the actual field materials and the ancient text of January 2017. First, Yuyin ShanFang is one of the famous garden in the Lingnan Region, and its total area is $1598m^2$. Wobin called the name 'Yuyin(餘蔭)' meaning the virtues of his ancestors. Second, if we analyze the poem written by Wobin, we can classify it as a phrase expressing the world beyond the future, a poem expressing the ideas of family and romantic ideas. Third, the space spread to the south around the shrine building in the middle of the site was largely a residential space, according to the analysis of the site's layout and spatial composition. Fourth, the spatial component of the hydronic acid is analyzed. The pavilion area is the Hanchwi-Pavilion, which is designated in the Wongrim, and Gyesang-Pavilion, which is a unique range that describes the peak of the garden. Fifth, Yuyin ShanFang has five ponds that are very diverse in shape. It is characteristic of us to stand on a technical boundary. Sixth, Seokgasan was referred to as Gyeongbansan, which was named after The builder Wobin and his descendants who passed it. Seventh, Hwachang is characterized by a wooden bull window and a compound glass. Eighth, the alumni style is not as diverse as the alumni style of the Suzhou traditional garden, but it features various forms and colorful pictures on the front of the alumni. Ninth, the one-piece sculptures of the interior of a building are expressed themes such as Gilsang, Sukjeong, Daoism, Palseom, and others. Finally, Trees planted in Yuyin ShanFang are mostly tropical plants, and some of them have symbolic meaning. Because the weather here is good for growing fruit, so planted a lot of fruit trees.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.