  • Since the commencement of the fuel cell business in 2007, POSCO POWER has been the major supplier of the MCFC (Molten Carbonate Fuel Cell), which is the most commercialized stationary fuel cell system in the world. With its quite, yet active movement, more than 20MW MCFC systems have been installed and are operating in Korea. While trying to localize the components and set up a firm supply chain in Korea to provide more reliable and cost-competitive products to its customers, POSCO POWER is also devoting itself to developing new MCFC application products. One such product is a back-up power system, in which a back-up algorithm is embedded to the present system so that the product can work as a back-up generator in case of grid failure. The technology to enhance load following capability of a stack module is also being developed with the back-up algorithm. Another example is a building application, the goal being to make the present Sub-MW product suitable for urban area. For this, downsizing and modularization are the main R&D scope. The project for developing ship service fuel cell for APU application will launch soon as well. In the project, a system which can operate in marine environment, and reforming technology for liquid logistic fuel will be developed.

  • PDF

외기온도 변화특성을 고려한 중앙냉방시스템의 에너지 절감 최적제어에 관한 연구 (Optimal Control Strategies for Energy Saving of Central Cooling System with Outdoor Air Temperature Changes)

  • 박기태;안병천
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4260-4266
    • /
    • 2015
  • 본 연구는 외기의 변화에 대해 쾌적성을 유지함과 동시에 열원 및 공조설비의 총 전력소비량을 최소화할 수 있는 최적 제어방법에 대한 시뮬레이션 연구를 수행하였다. 최적제어방법은 외기 건구 및 습구온도 등의 환경변수가 변할 경우 냉각수온도, 급기온도, 냉수온도 등의 제어변수 최적 설정값들이 결정되도록 함으로써 환경 변화에 따라 최대 및 부분부하운전을 적절히 수행하도록 한 것이다. TRNSYS 프로그램을 이용하여 시스템을 모델링하였으며, 본 연구에서 제시한 최적제어방법과 고정 설정값으로 운전한 기존의 방식의 제어성능을 비교 분석하였다. 연구결과로는 본 연구에서 제시한 최적제어방법이 기존 운전방식에 비해 에너지 절감 성능이 양호함을 알 수 있었다.

축냉시스템의 산업용 생산설비 적용에 대한 고찰 (Study on TES system application for industrial production facility)

  • 박창현;홍승수;김종률;박승상;황형식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

해수열원 히트펌프 시스템의 설계 및 운전 (A Design and Test of a Sea Water Source Heat Pump System)

  • 이재훈;김지영;백영진;장기창;나호상;신광호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1273-1278
    • /
    • 2008
  • A sea water source cascade heat pump was designed and tested in this study. The system was designed to perform a single stage operation in summer, as well as a cascade operation in winter to ensure the high temperature lift. A steady-state simulation model was developed to analyze and optimize its performance. The simulation results show that the R717 exhibits best performance among combinations considered in this study. A R410A also exhibits the highest performance among HFCs with the smallest compressor displacement. A 15-RT R410A-R134a pilot system was installed in the 5-story commercial building at Samcheok City by the East Sea. A scroll type R410A compressor, a reciprocating type R134a compressor, plate type condenser/ evaporator/ cascade heat exchanger and two electronic expansion valves were used to build a pilot. A titanium plate type heat exchanger is also used for the heat exchanging with a sea water. The heat source/sink water is supplied from the well below the seashore in the depth of 5 m. In the initial test of the system, supply water temperature was rising up to $67^{\circ}C$ using a sea water heat source of $9^{\circ}C$, while an ambient temperature was $4.5^{\circ}C$.

  • PDF

공기식 집열 지붕 난방시스템의 실험 연구 (An Experimental Study of Solar fir Roof Heating System With PVT Collector)

  • 강준구;김진희;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.232-237
    • /
    • 2008
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This research is about the development of solar roof system with PV/T collector to apply into buildings. A test cell experiment was performed with the PVT roof installed: It found that the hot air supply from the PVT air collector contributed to increase the heating efficiency by 2 times and the electrical efficiency by about 8%.

  • PDF

지역 건축물의 에너지 자립을 위한 패시브 외단열 복합패널 개발 연구 (Development of the Passive Outside Insulation Composite Panel for Energy Self-Sufficiency of Building in the Region)

  • 문선욱
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.11-18
    • /
    • 2018
  • The study aims to address the energy crisis and realize self-sufficiency of building as part of local energy independence, breaking away from a single concentrated energy supply system. It is intended to develop modules of the outside insulation composite panels that conform to passive certification criteria and for site-assembly systematization. The method of study first identifies trends and passive house in literature and advanced research. Second, the target performance for development is set, and the structural material is selected and designed to simulate performance. Third, a test specimen of the passive outside insulation curtain wall module designed is manufactured and constructed to test its heat transmission coefficient, condensation performance and airtightness. Finally, analyze performance test results, and explore and propose ways to improve the estimation and improvement of incomplete causes to achieve the goal. The final test results achieved the target performance of condensation and airtightness, and the heat transmission coefficient was $0.16W/(m^2{\cdot}K)$, which is $0.01W/(m^2{\cdot})K$ below the performance target. As for the lack of performance, we saw a need for a complementary design to account for simulation errors. It also provided an opportunity to recognize that insulated walls with performance can impact performance at small break. Thus, to be commercialized into a product with the need for improvement in the design of the joint parts, a management system is needed to increase the precision in the fabrication process.

부산 영도구 공동주택에 대한 풍력발전 도입가능성 (A Feasibility Study on the Wind Power Plant for Common Residential Buildings in Youngdo Island, Busan)

  • 황광일;김지훈;신현호;이수호;한제덕
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.255-256
    • /
    • 2006
  • A wind power plant is one of the competitive and effective energy among the regulated 13 renewable energies, especially for the seashore and island. This study is focused on the possibility of wind power plant as a on-site electric power supply system for the common residential building in Youngdo, Busan. The following show the results of this study. 26 apartments' monthly electric power consumptions are surveyed and monthly variations are stable comparing to the metropolitan. With the wind speed measured in Youngdo island and wind power plant efficiency data, the simulation is conducted and the result shows that 35 wind power units are satisfied with full electric power load for all the common residential buildings in Youngdo island.

  • PDF

해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구 (A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings)

  • 김명래;윤재옥
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

태양열 축열조가 없는 변유량 제어 방식의 지역난방용 태양열시스템 실증시험연구 (The Development of the Climatic Design Tool for Energy Efficient Building Design)

  • 백남춘;신우철;이진국;윤응상;윤석만
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.21-27
    • /
    • 2008
  • In this study, the design of the solar heating system for district heating as well as it's operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

해수열원 히트펌프 시스템의 운전특성 (The Operation Characteristics of a Sea Water Source Heat Pump System)

  • 장기창;백영진;나호상;김지영;이재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1353-1357
    • /
    • 2008
  • A sea water source cascade heat pump was designed and tested in this study. The system was designed to perform a single stage operation in summer, as well as a cascade operation in winter to ensure the high temperature lift. A steady-state simulation model was developed to analyze and optimize its performance. The simulation results show that the R717 exhibits best performance among combinations considered in this study. A R410A also exhibits the highest performance among HFCs with the smallest compressor displacement. A 15-RT R410A-R134a pilot system was installed in the 5-story commercial building at Samcheok City by the East Sea. A scroll type R410A compressor, a reciprocating type R134a compressor, plate type condenser/ evaporator/ cascade heat exchanger and two electronic expansion valves were used to build a pilot. A titanium plate type heat exchanger is also used for the heat exchanging with a sea water. The heat source/sink water is supplied from the well below the seashore in the depth of 5 m. In the initial test of the system, supply water temperature was rising up to $67^{\circ}C$ using a sea water heat source of $9^{\circ}C$, while an ambient temperature was $4.5^{\circ}C$.

  • PDF