• Title/Summary/Keyword: Building energy consumption characteristics

Search Result 143, Processing Time 0.024 seconds

Households' Characteristics in Energy Consumption Data from Carbon Emission Monitoring System (CEMS) in Sejong City, Korea (가구 탄소모니터링 시스템에 의한 탄소배출특성 - 세종시 첫마을을 대상으로 -)

  • Leem, Yountaik;Lee, Sang Ho
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.55-65
    • /
    • 2013
  • Korean Government has developed Sejong City as a new administration city. This city of future was planned and designed toward one of the most eco-friendly city on the basis of ICTs. To attain this object, a carbon emission monitoring system (CEMS) was designed and installed as a part of u-city service which provides various information anytime and anywhere to enrich the people's quality of life. In this paper, at first, the structure and functions of CEMS are introduced. This system is consist of 5 parts - data collection from user and linked public DBs, transforming data into meaningful information for the policy makers, system-user interfacing via statistical tables and graphs, and system maintenance. This system can be operated by the citizen participation through whole the process. With the help of GIS map and graphic interface, statistics of monitored data for both citizen and decision maker provided and after feed-back, they have affected on the behaviour of citizen's energy consumption and related policy as well. By the CEMS, energy consumption data of 124 agreed households were collected during 9 months in 2012. Electricity, gas and water consumption were remote-metered automatically by the system and analysed. This showed that more than 85% of CO2 emission is rely on electricity usage. Furthermore, number of family members and size of house influences on the emission of CO2 by each household together with the life-style of the occupants. Electricity and water consumption showed the seasonal factor while gas consumption represents the number of family members. Even this paper has limitations caused by 9 months of data collection, it shows the policy directions to reduce the emission of CO2 focusing on the house size and number of family members of each households. With the result of this research, life-style of the generation of dwellers should be investigated and the CO2 emission characteristics of other housing type as well for the data building for future policy making.

The Method of Quantitative Analysis Based on Big Data Analysis for Explanatory Variables Containing Uncertainty of Energy Consumption in Residential Buildings - Focused on Apartment in Seoul Korea (주거용 건물의 에너지 실사용량의 불확실성을 내포한 설명변수 인자에 대한 빅데이터 분석 기반의 정량화 방법 - 서울지역의 공동주택을 중심으로)

  • Choi, Jun-Woo;Ahn, Seung-Ho;Park, Byung-Hee;Ko, Jung-Lim;Shin, Jee-Woong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: The energy consumption of apartment units is affected by the lifestyle of the residents rather than system technology. In this study the numerical analysis of assumed energy consumption correlation factors with arbitrary value due to uncertainty. It is intended to be used as a simulation correction value which can be utilized as a predicted value of actual energy usage. The correction value of the simulation is set in the developed form of the existing process that derives the actual usage amount. The simulation results used in the existing evaluation system are used to maintain the useful value as the current system evaluation scale and predict the actual capacity. Method: The method of the study is to statistically analyze the data frames of all complexes capable of collecting the annual energy usage and to reconstruct the population by adding the variables that are expected to be correlated. Repeat the data frame configuration with variables that are assumed to be highly correlated with energy use levels. Determine whether there is correlation or not. The intensity of the external characteristics of the building equipment related to the energy consumption is presented as the quantitative value. Result: The correlation between electricity consumption and trading price since 2010 is analyzed as (Correlation coefficient 0.82). These results are higher than (Correlation coefficient 0.79), which is the correlation between residential area and trading price. This paper signifies the starting point of the methodology that broadens the field of view of verification of simulation feasibility limited to the prediction technique focused on the simulation tool and the element technology scope.The diversified phenomenon reproduction method develops the existing energy simulation method.It can be completed with a simulation methodology that can infer actual energy consumption.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul- (공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 -)

  • Park, So-Yun;Lee, Yun-Jae;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

Comparison on the Energy Performance of Underfloor Air Distribution System According to Modeling Method Using EnergyPlus (EnergyPlus를 이용한 바닥공조시스템의 모델링 방법에 따른 에너지 성능 비교)

  • Jang, Hyang-In;Yoon, Seong-Hoon;Lee, Hyun-Soo;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.718-723
    • /
    • 2012
  • The purpose of this study is to propose modeling method of Underfloor Air Distribution System with reliability and validity by comparing characteristics of modeling methods. For this, the modeling methods of UFAD were selected by investigating various modeling methods of previous researches. Then, simulations were conducted by using EnergyPlus which is dynamic analysis program of building energy. Annual energy consumption for each method was compared with a wide range of indoor thermal loads. As a result, the methodology of reducing internal gains can cause under sizing of the system. It suggests modeling methods to reflect occupied zone air-conditioning, temperature stratification and supply plenum which are the main characteristics of UFAD.

Performance of heat sinks for LED luminaires in office buildings - Focused on the variation of air flow rate in duct - (사무소건물의 LED조명기구 방열장치의 성능 분석 연구 - 덕트 내 유량변화 중심으로 -)

  • Park, Ji-Woo;Ahn, Byung-Lip;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.81-86
    • /
    • 2014
  • In recent years, many researchers have considered the building energy consumption reduction accordingly to deal with abnormal climate changes and greenhouse gas reduction. However, the lighting energy use ratio has increased in spite of the development of the high efficiency lighting device. Therefore, the study aims to produce the LED lighting applications for the effective lighting heat removal by using the heat characteristics of LED lighting and analyzing the heat removal effect. In order to increase radiant heat efficiency, the heat pipe and heat sink was attached on PCB as LED lighting applications. Experiment was conducted to verify the temperature and air velocity of inside duct: thermocouples, anemometer. The heat removal effect of LED lighting applications was measured by observing the temperature of the lighting applications and the change of air velocity in duct. The experiment shows that the temperature change in the duct according to air velocity was $0.9{\sim}5.8^{\circ}C$. It is also concluded that heat removal was calculated from 33 to 81W.

Strategy of Energy Saving and Thermal Environment Improvement for Intermittent Heating System in Apartment Buildings (공동주택 간헐난방시스템의 에너지 절감 및 열환경 개선방안 연구)

  • Ahn Byung-Cheon;Lee Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.88-93
    • /
    • 2005
  • In this study, the operational characteristics on heating performance and energy consumption for intermittent hot water heating system in apartment buildings were research by simulation. The effects of apartment inlet hot water temperature and operation time per day on energy consumption and indoor thermal environment are investigated. The strategy of energy saving and thermal environment improvement is suggested in comparison with the existing ones.

Analysis of Energy Consumption Characteristics of Education Facilities in Korea (국내 초·중등 교육시설의 에너지 소비 특성 분석)

  • Lee, Jae-Ho;Hyun, In-Tak;Yoon, Yeo-Beom;Lee, Kwang Ho;Chin, Kyung Il
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.59-65
    • /
    • 2014
  • Nowadays, reduction of energy use in buildings is a big issue, especially in public buildings like schools. The building structure is very simple in that, the room size, schedule and user number is similar across different schools. There are many policies which are suitable for this kind of buildings. Investigation of energy consumption pattern in primary school, middle school and high school in different cities of Korea has been done in this paper using statistical data from national organization and the data from IBM and Gyeonggi Provincial Office of Education, aimed at providing the basic data for the development of energy efficiency improvement policies of educational facilities. The study was divided according to climate, energy source type and public or private school, as different cities have different climates and accordingly different amount of energy sources are used. It was observed that, the average energy consumption in primary school is $36.9kWh/m^2$, in middle school is $20.5kWh/m^2$ and in high school $27.4kWh/m^2$. As further analysis, monthly energy consumption pattern has been analyzed for one city.

Influence of Air-tightness on Heat Energy Performance in Post and Beam Building with Exposed Wood Frame

  • Kim, Hyun-Bae;Kim, Se-Jong;Oh, Jung-Kwon;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.319-326
    • /
    • 2012
  • Han-green building is one of the modernized Korean traditional buildings developed by Korea Forest Research Institute. This building was developed to increase the competitiveness of Korean traditional building using state-of-art technologies; hence Han-green building has the inherent characteristics of traditional building such as exposed wood frame in wall. Because of discontinuity in wall by the exposed wood frame, there is a concern on heat-air leaking in terms of energy performance. In this study, air-tightness of Han-green building was evaluated to investigate the influence of gaps between frames and in-fill walls. Blower door test was carried out to evaluate the air-tightness, and air-change rate (ACH50) was evaluated by averaging four set of pressurization and depressurization test. The air-change rate of Han-green house was 5.91 $h^{-1}$. To improve energy performance of Han-green house, thermal infrared images of Han-green house were taken in winter with heating to find out where the heat loss occurred. It was found that the building lost more heat through gaps between frames and in-fill walls rather than through other parts of this building. After covering all the gaps by taping, the blower door test was performed again, and the air-change rate was improved to 5.25 $h^{-1}$. From this analysis, it was concluded that the heated air can leak through the gaps between frames and walls. Therefore, when one designs the post and beam building with exposed frame, the detail design between frame and wall needs to be carefully dealt. However, Han-green building showed relatively high air-tightness comparing with other country research results.