• Title/Summary/Keyword: Building damages

Search Result 349, Processing Time 0.026 seconds

Vibration Regulations and Damages Evaluation Method for Human (인체에 대한 진동의 허용 기준 및 피해 산정에 관한 연구)

  • 양형식;전양수;이경운
    • Tunnel and Underground Space
    • /
    • v.7 no.4
    • /
    • pp.310-322
    • /
    • 1997
  • New limits of comfort boundary, psychological damage boundary and exposure limit for building residents by continuous and vibration are suggested. These limits are derived from the ISO 2631 and DIN 4150 regulations. A reasonable method to evaluate damages by vibrations is also suggested using the "total over-exposure of vibration" concept.; concept.

  • PDF

A Basic Study on Influential Factors of Building Damages According to Hurricane by Using Correlation Analysis (상관분석을 통한 태풍에 따른 건축물 피해액의 영향인자 도출)

  • Kim, Boo-Young;Yang, Seongpil;Kim, Sangho;Son, Kiyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.164-165
    • /
    • 2014
  • In the case of U.S, various damage prediction models of buildings from natural disasters have been used widely in many organizations such as insurance companies and governments. In South Korea, although studies regarding damage prediction model of hurricane have been conducted, the scope has been only limited to consider the property of hurricane. However, it is necessary to consider various factors such as socio-economic, physical, geographical, and built environmental factors to predict the damages. Therefore, as a basic study on a damage prediction model development of buildings, this study is to analyze the correlation between various factors related to hurricane. The findings of study can be utilized to develop for predicting the damage of hurricane on buildings.

  • PDF

The effect of short columns on the performance of existing buildings

  • Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • v.46 no.4
    • /
    • pp.505-518
    • /
    • 2013
  • In this study, the seismic performance of a residential building which was damaged in the 1992 Erzincan (Turkey) Earthquake (Ms = 6.8) is performed. Damages on columns due to short columns are estimated analytically implementing the shear hinges and results are compared with the observed damages on the building after the earthquake. In seismic performance evaluation, a deformation based approach is adopted, whereby the structural behavior under external and seismic loads is evaluated. Furthermore, the effects of short columns formed by band windows in basement floors are investigated analytically. The sizes of band windows are parametrically changed in order to understand the effects of short columns on overall building behavior.

Comparing the dynamic behavior of a hospital-type structure with fixed and isolated base

  • Nasery, Mohammad Manzoor;Ergun, Mustafa;Ates, Sevket;Husem, Metin
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.657-671
    • /
    • 2015
  • The level of ductility is determined by depending on the intended use of the building, the region's seismic characteristics and the type of structural system when buildings are planned by engineers. Major portion of seismic energy is intended to be consumed in the plastic zone in structural systems of high ductility, so the occurrence of damages in load bearing and non-load bearing structural elements is accepted in planning stage under severe earthquakes. However, these damages must be limited among specific values in order not to endanger buildings in terms of the bearing capacity. Isolators placed between the basement and upper structure make buildings behave elastically by reducing the effects of seismic loads and improving seismic performance of building significantly. Thus, damages can be limited among desired values. In this study, the effectiveness of seismic isolation is investigated on both fixed based and seismic isolated models of a hospital building with high ductility level with regard to lateral displacements, internal forces, structural periods and cost of the building. Layered rubber bearings are interposed between the base of the structure and foundation. Earthquake analysis of the building are performed using earthquake records in time domain (Kocaeli, Loma Prieta and Landers). Results obtained from three-dimensional finite element models are presented by graphs and tables in detail. That seismic isolation reduces significantly the destructive effects of earthquakes on structures is seen from the results obtained by seismic analysis.

Simulation of cyclic response of precast concrete beam-column joints

  • Adibi, Mahdi;Talebkhah, Roozbeh;Yahyaabadi, Aliakbar
    • Computers and Concrete
    • /
    • v.24 no.3
    • /
    • pp.223-236
    • /
    • 2019
  • Experience of previous earthquakes shows that a considerable portion of concrete precast buildings sustain relatively large damages especially at the beam-column joints where the damages are mostly caused by bar slippage. Precast concrete buildings have a kind of discontinuity in their beam-column joints, so reinforcement details in this area is too important and have a significant effect on the seismic behavior of these structures. In this study, a relatively simple and efficient nonlinear model is proposed to simulate pre- and post-elastic behavior of the joints in usual practice of precast concrete building. In this model, beam and column components are represented by linear elastic elements, dimensions of the joint panel are defined by rigid elements, and effect of slip is taken into account by a nonlinear rotational spring at the end of the beam. The proposed method is validated by experimental results for both internal and external joints. In addition, the seismic behavior of the precast building damaged during Bojnord earthquake 13 May 2017, is investigated by using the proposed model for the beam-column joints. Damage unexpectedly inducing the precast building in the moderate Bojnord earthquake may confirm that bearing capacity of the precast building was underestimated without consideration of joint behavior effect.

Development of an integrated approach for Algerian building seismic damage assessment

  • Boukri, Mehdi;Farsi, Mohammed Naboussi;Mebarki, Ahmed;Belazougui, Mohamed
    • Structural Engineering and Mechanics
    • /
    • v.47 no.4
    • /
    • pp.471-493
    • /
    • 2013
  • This paper presents a framework for seismic damage evaluation for Algerian buildings adapted from HAZUS approach (Hazard-United States). Capacity and fragility curves were adapted to fit the Algerian building typologies (Reinforced Concrete structures, Confined or Non-Confined Masonry, etc). For prediction purposes, it aims to estimate the damages and potential losses that may be generated by a given earthquake in a prone area or country. Its efficiency is validated by comparing the estimated and observed damages in Boumerd$\grave{e}$s city, in the aftermath of Boumerd$\grave{e}$s earthquake (Algeria: May $21^{st}$ 2003; $M_w$ = 6.8). For this purpose, observed damages reported for almost 3,700 buildings are compared to the theoretical predictions obtained under two distinct modelling of the seismic hazard. In one hand, the site response spectrum is built according to real accelerometric records obtained during the main shock. In the other hand, the effective Algerian seismic code response spectrum (RPA 99) in use by the time of the earthquake is considered; it required the prior fitting of Boumerd$\grave{e}$s site PGA (Peak Ground Acceleration) provided by Ambraseys' attenuation relationship.

Seismic characteristics of a Π-shaped 4-story RC structure with open ground floor

  • Karabini, Martha A.;Karabinis, Athanasios J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • v.22 no.4
    • /
    • pp.345-353
    • /
    • 2022
  • The configuration of an open ground floor (pilotis) is a common and very critical irregularity observed in multistory reinforced concrete frame structures. The characteristics and the geometrical formation of the beams of the first story proved to be a critical parameter for the overall seismic behavior of this type of Reinforced Concrete (RC) structures. In this work the combination of open ground floor (pilotis) morphology with very strong perimetrical beams at the level of the first story is studied. The observation of the seismic damages and the in situ measurements of the fundamental period of four buildings with this morphology and Π-shaped plan view are presented herein. Further analytical results of a pilotis type Π-shaped RC structure are also included in the study. From the measurements and the analytical results yield that the open ground floor configuration greatly influences the fundamental period whereas this morphology in combination with strong beams can lead to severe local shear damages in the columns of the ground floor. The structural damage was limited in the columns of the ground floor and yet based on the changes of the in situ measured fundamental period the damaged level is assessed as DI=88%. Furthermore, due to the Π-shape of the plan view the tendency of the parts of the building to move independently strongly influences the distribution of the damages over the ground floor vertical elements.

Building mix design and quality control measures to reduce the combined deterioration of plain concrete in harsh environments (혹독한 환경에서의 무근콘크리트 복합열화 저감을 위한 배합설계 및 품질관리 방안 구축)

  • Kim, Dae-Geon;Park, Chan-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.85-86
    • /
    • 2016
  • Recently damages caused by the additional costs and degradation in durability combined deterioration due to plain concrete deterioration has occurred. In particular, in the case of the finish that is not exposed to the outside air in the concrete to respond to the harsh environment (freeze-thawing, calcium laying, etc.), to establish a quality control way for the process and the concrete mix design for it.

  • PDF

Estimation of the Damage using Tilt Switch Sensors in RC Beams (기울기 스위치 센서를 이용한 철근콘크리트 보의 손상평가)

  • Kim, Dong-Hyun;Kim, Tae-Gon;Choi, Young-Wha;Lim, Heun-Wook;Joo, Jae-Yong;Si, Sung-Dung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.15-16
    • /
    • 2012
  • The estimation of crack damages is studied using the radio frequency system and tilt switch sensors in RC beams. If load is received on the center of the flexible specimen, sensor housing using cement mortar of the flexible specimen will be destroyed, and these are become to send signals of damages at the radio frequency system connected with tilt switch sensors. This study is fundamental research for the estimation of the damage using tilt switch sensors in RC beams.

  • PDF

A Study on the Damage Detect using Static Displacement Sensors in Concrete Elements (정적변위센서를 이용한 콘크리트부재의 손상검토)

  • Kim, Ie-Sung;Choi, Young-Wha;Kim, Dong-Hoo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.157-158
    • /
    • 2011
  • The monitoring to crack damages is studied using the radio frequency system and static displacement sensors. If load is received on the center of the flexible specimen, bonded sensors will be destroyed, and these are become to send signals of damages at the radio frequency system connected with sensors. This study is fundamental research of the monitoring damage system for diagnostic concrete elements using the radio frequency system and static displacement sensors.

  • PDF