• 제목/요약/키워드: Building damage

검색결과 1,544건 처리시간 0.023초

Fragility based damage assesment in existing precast industrial buildings: A case study for Turkey

  • Senel, Sevket Murat;Kayhan, Ali Haydar
    • Structural Engineering and Mechanics
    • /
    • 제34권1호
    • /
    • pp.39-60
    • /
    • 2010
  • In Turkey, majority of industrial facilities are composed of precast buildings. However, precast buildings have suffered extensive damage during Kocaeli and Duzce (1999) and Adana-Ceyhan (1998) earthquakes. Therefore, in this study, fragilities of existing building stock and damage probabilities of precast buildings were studied. For this purpose, building inventories were prepared and variation of structural parameters was determined by investigating the design project of 65 precast buildings constructed in Denizli, Turkey. Twelve analysis models which reflect the stiffness, strength and ductility properties of building inventory were constructed. After the definition of strain based displacement limits and corresponding damage states for buildings, displacement demands were calculated by using non linear time history analysis. During the analyses 360 strong ground motion records were used. Exceedence ratios of concerned damage limits was calculated by checking the displacement demands and then PGV based fragility curves were constructed. Efficiency of strength, stiffness and ductility properties of existing precast buildings were investigated by comparing the fragility curves. The results have shown that the most effective parameters that govern the damage probabilities of precast buildings are stiffness and ductility. It was also stated that the results of fragility analysis and damage and failure observations performed after Kocaeli and Duzce Earthquakes are compatible.

Integrated vibration control and health monitoring of building structures: a time-domain approach

  • Chen, B.;Xu, Y.L.;Zhao, X.
    • Smart Structures and Systems
    • /
    • 제6권7호
    • /
    • pp.811-833
    • /
    • 2010
  • Vibration control and health monitoring of building structures have been actively investigated in recent years but treated separately according to the primary objective pursued. This paper presents a general approach in the time domain for integrating vibration control and health monitoring of a building structure to accommodate various types of control devices and on-line damage detection. The concept of the time-domain approach for integrated vibration control and health monitoring is first introduced. A parameter identification scheme is then developed to identify structural stiffness parameters and update the structural analytical model. Based on the updated analytical model, vibration control of the building using semi-active friction dampers against earthquake excitation is carried out. By assuming that the building suffers certain damage after extreme event or long service and by using the previously identified original structural parameters, a damage detection scheme is finally proposed and used for damage detection. The feasibility of the proposed approach is demonstrated through detailed numerical examples and extensive parameter studies.

Field Investigation of Debris Flow Hazard Area on the Roadside and Evaluating Efficiency of Debris barrier

  • Lee, Jong Hyun;Lee, Jung Yub;Yoon, Sang Won;Oak, Young Suk;Kim, Jae Jeong;Kim, Seung Hyun
    • 지질공학
    • /
    • 제25권4호
    • /
    • pp.439-447
    • /
    • 2015
  • In this study, specific sections vulnerable to debris flow damage were selected, and a complete enumeration survey was performed for the sections with debris flow hazards. Based on this, the characteristics of the sections with debris flow hazards and the current status of actions against debris flow were examined, and an efficient installation plan for a debris flow damage prevention method that is required in the future was suggested. The results indicated that in the Route 56 section where the residential density is relatively higher between the two model survey sections, facilities for debris flow damage reduction were insufficient compared to those in the Route 6 section which is a mountain area. It is thought that several sites require urgent preparation of a facility for debris flow damage reduction. In addition, a numerical analysis showed that for debris barriers installed as a debris flow damage prevention method, distributed installation of a number of small-scale barriers facilities within a valley part was more effective than single installation of a large-scale debris barrier at the lower part of a valley.

도심지 깊은굴착시 주변 건물 및 매설관 손상평가 (Deep Excavation-induced Building and Utility Damage Assessment)

  • 유충식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.85-95
    • /
    • 2002
  • A substantial portion of the cost of deep excavations in urban environments is devoted to prevent ground movements and their effects on adjacent buildings and utilites. Prediction of ground movements and assessment of the risk of damage to adjacent structures has become an essential part of the planning, design, and construction of a deep excavation project in the urban environments. This paper presents damage assessment techniques for buildings and utilities adjacent deep excavation, which can be readily used in practice.

  • PDF

고출력펄스 레이저 기반 비접촉 콘크리트 열화깊이 추정 기법 검토 (Review of Non-Contact Concrete Damage Depth Estimation Technique Based on High-Power Pulsed Laser)

  • 최경철;김홍섭;전준서;김은영;이문환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.267-268
    • /
    • 2023
  • Out of an estimated 7 million buildings nationwide, approximately 38% of them have been standing for over 30 years, and this number is expected to continue to increase. Additionally, due to the Building Act, safety inspections will be mandatory for approximately 70,000 buildings annually, leading to an increase in demand for building safety inspections. However, the current building safety diagnosis heavily relies on manpower, making it difficult to diagnose locations that are hard to access, and requiring lengthy investigation periods. Therefore, this paper presents the basic research results of a non-contact concrete damage depth estimation technique using laser technology aimed at remote building safety diagnosis and shortening investigation periods.

  • PDF

Strengthening sequence based on relative weightage of members in global damage for gravity load designed buildings

  • Niharika Talyan;Pradeep K. Ramancharla
    • Earthquakes and Structures
    • /
    • 제26권2호
    • /
    • pp.131-147
    • /
    • 2024
  • Damage caused by an earthquake depends on not just the intensity of an earthquake but also the region-specific construction practices. Past earthquakes in Asian countries have highlighted inadequate construction practices, which caused huge life and property losses, indicating the severe need to strengthen existing structures. Strengthening activities shall be proposed as per the proposed weighting factors, first at the higher weighted members to increase the capacity of the building immediately and thereafter, the other members. Through this study on gravity load-designed (GLD) buildings, relative weights are assigned to each storey and exterior and interior columns within a storey based on their contribution to the energy dissipation capacity of the building. The numerical study is conducted on mid-rise archetype GLD buildings, i.e., 4, 6, 8, and 10 stories with variable storey heights, in the high seismic zones. Non-linear static analysis is performed to compute weights based on energy dissipation capacities. The results obtained are verified with the non-linear time history analysis of 4 GLD buildings. It was observed that exterior columns have higher weightage in the energy dissipation capacity of the building than interior columns up to a certain building height. The damage in stories is distributed in a convex to concave parabolic shape from bottom to top as building height increases, and the maxima location of the parabola shifts from bottom to middle stories. Relative weighting factors are assigned as per the damage contribution. And the sequence for strengthening activities is proposed as per the computed weighting factors in descending order for regular RCC buildings. Therefore, proposals made in the study would increase the efficacy of strengthening activities.

GIS기반의 터널시공에 따른 주변건물/매설관 손상평가 시스템-개발 및 적용 (GIS-based Tunnelling-induced Building/Utility Damage Assessment System-Development and Application)

  • 유충식;전영우;김재훈;박영진;유정훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.233-240
    • /
    • 2003
  • A GIS-based tunnelling risk management system (GIS-TURIMS) has been developed in this study The developed system uses ArcView 8.2 as a basic platform and the built-in interface(VBA) has been used to perform first-order simplified analyses for prediction of tunnelling-induced ground movements and building damage assessment. The main emphasis in this study was to develop a working framework that can be used in the perspective of tunnelling risk management. The developed system is capable of carrying out computationally intensive first-order analyses for ground movement prediction as well as building/utilities damage assessment with fully taking advantage of the GIS technologies. This paper describes the concept and details of the GIS-TURIMS development and implementation.

  • PDF

Correlation of damage and analysis of R/C building: Experience from the 1995 Kobe earthquake

  • Matsumori, Taizo;Otani, Shunsuke
    • Structural Engineering and Mechanics
    • /
    • 제6권8호
    • /
    • pp.841-856
    • /
    • 1998
  • During the 1995 Hyogoken-Nanbu Earthquake, a reinforced concrete building, called Jeunesse Rokko, suffered intermediate damage by forming a beam-yielding (weak-beam strong-column) mechanism, which has been regarded as the most desirable earthquake resisting mechanism throughout the world. High cost to repair damage at many beam ends and poor appearance expected after the repair work made the owner decide to tear down the building. Nonlinear earthquake response analyses were conducted to simulate the behavior of the building during the earthquake. The influence of non-structural members was considered in the analysis. The calculated results were compared with the observed damage, especially the location of yield hinges and compression failure of spandrel beams, and the degree of cracking in columns and in column-girder connections.

A probabilistic analytical seismic vulnerability assessment framework for substandard structures in developing countries

  • Kyriakides, Nicholas;Ahmad, Sohaib;Pilakoutas, Kypros;Neocleous, Kyriacos;Chrysostomou, Christis
    • Earthquakes and Structures
    • /
    • 제6권6호
    • /
    • pp.665-687
    • /
    • 2014
  • This paper presents a framework for analytical seismic vulnerability assessment of substandard reinforced concrete (RC) structures in developing countries. Amodified capacity-demand diagram method is used to predict the response of RC structures with degrading behaviour. A damage index based on period change is used to quantify the evolution of damage. To demonstrate the framework, a class of substandard RC buildings is examined. Abrupt accumulation of damage is observed due to the brittle failure modes and this is reflected in the developed vulnerability curves, which differ substantially from the curves of ductile structures.

국부충격에 의한 전단건물의 손상곡선 (Damage Curves for the Shear Building to the Local Impact)

  • 이상호;황신우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권4호
    • /
    • pp.247-256
    • /
    • 2004
  • 하층충격에 의한 2층 전단건물의 손상곡선을 엄계변위를 발생시키는 하중최대치 비와 임펄스 비를 이용하여 작성하였다. 손상곡선 작성에 필요한 구조물의 거동파악은 하중과 임펄스 응답행렬의 합성곱을 이용하여 구하였으며, 합성곱에 필요한 임펄스응답행렬은 모드중첩법을 이용하여 구하였다. 작성된 손상곡선으로부터 하층충격에 의한 각층의 안전성은 상층은 하중의 최대치에 그리고 하층은 임펄스의 크기에 민감한 것으로 파악되었다.