• Title/Summary/Keyword: Building block method

Search Result 197, Processing Time 0.03 seconds

Constraints Evaluation for Ship-building Industry

  • Back Dong-Sik;Yoon Duck-Young
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.40-44
    • /
    • 2004
  • A fact that limits a company's ability to achieve more of its goal is referred to as a 'constraint' shipbuilding industries need to identify and manage constraints. The theory of constraints is evolved out of the problems of bottleneck formation. This happens and is conserved for the formulation if various real time problems for arriving standard uniquely addressed problems If, for example, the goal of a shipbuilding industry is to make money now and in the future, it is suggested that TOC will enable th mangers of the company to do so. TOC, focuses the organization scare resources on improving the performance of the true constraints, and therefore the bottom line of the organization. An attempt is made for the implantation of the theory into real world shipyard decision support mechanism.

  • PDF

Implementation and the Energy Efficiency of the Kinetic Shading System (가동형 차양 시스템의 구성과 에너지 효율)

  • Han, Seung-Hoon
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.67-73
    • /
    • 2014
  • This study aims at examining kinetic efficient shading systems and their implementation methods. These days, the importance of the shading devices are getting more significant due to the energy problem. Cordially, suitable shade designs are required as an important element for the exterior envelope of the building. This study employs the optimal shading design as an efficient shading method with the kinetic system that can be converted actively by the altitude of the sun. The proposed kinetic shading system works not only as a lightshelf in case the altitude of the sun is high but also as a vertical louver when the sun is getting lower in order to block the direct sunlight. This study has analyzed the thermal performance and shading coefficient of the kinetic shading system in comparison to existing fixed shading devices using the Ecotect. The results, in sum, conclude that the suggested kinetic shading system could decrease direct sunlights 26.2% more than the existing shading methods.

Behavior analysis of aerial tunnel maintenance truss platform with high tensile steel UL-700

  • Lee, Dongkyu
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.513-521
    • /
    • 2017
  • The goal of this study is to investigate structural analysis and behaviors of an innovative aerial work platform truss frame whose ductility is improved by using high strength-steel UL-700. The present space truss frame can move or stop through tunnels for maintenance constructions by automatic facilities and workmanship within standardized limited building lines of tunnel. Most of all, this method overcomes problematic, which is to block cars during construction periods, seriously, of typical methods like as using truck and scaffolds for tunnel maintenance. According to evaluated appropriate design results of space truss frames of numerical examples by using a commercial MIDAS GEN program, it is verified that design parameters such as layered size, cross-sectional size, and steel material of the present space truss frame are determined to depend on characteristics such as lanes or shape of road tunnels.

Modeling of 3-D Embedded Inductors Fabricated in LTCC Process (저온 동시소성 공정으로 제작된 3차원 매립 인덕터 모델링)

  • 이서구;최종성;윤일구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.4
    • /
    • pp.344-348
    • /
    • 2002
  • As microelectronics technology continues to progress, there is also a continuous demand on highly integration and miniaturization of systems. For example, it is desirable to package several integrated circuits together in multilayer structure, such as multichip modules, to achieve higher levels of compactness and higher performance. Passive components (i.e., capacitors, resistors, and inductors) are very important fort many MCM applications. In addition, the low-temperature co-fired ceramic (LTCC) process has considerable potential for embedding passive components in a small area at a low cost. In this paper, we investigate a method of statistically modeling integrated passive devices from just a small number of test structures. A set of LTCC inductors is fabricated and their scattering parameters (s-parameters) are measured for a range of frequencies from 50MHz to 5GHz. An accurate model for each test structure is obtained by using a building block based modeling methodology and circuit parameter optimization using the HSPICE circuit simulator.

PWM synchronization method of parallel operating inverters with Serial-communication (직렬 통신을 이용한 병렬 운전 인버터의 PWM 동기화 알고리즘)

  • Lee, Seong-Yong;Park, Young-Min
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.41-42
    • /
    • 2016
  • 배터리 에너지 저장 시스템이나 태양광 발전 시스템은 흔히 용량 확장, 신뢰성 향상, 효율 향상 등을 목적으로 계통연계형 인버터를 다수 모듈형으로 병렬 구성하게 된다. 이렇게 DC전원을 공유하면서 인버터 출력단을 하나로 묶어 운전하는 경우에 순환전류가 문제가 될 수 있는데, 계통주파수에 해당하는 위상 차 뿐만 아니라 수 kHz의 동기화 되지 않은 PWM 캐리어 위상 차에 의해서도 순환전류가 발생할 수 있다. 따라서 본 논문에서는 PWM 동기화를 위하여, PEBB(Power Electronics Building Block) 개념을 사용하는 다수 대의 인버터가 직렬 또는 병렬로 구동될 때, 직렬 통신을 이용하여 PWM 캐리어들을 정밀하게 동기화 시키는 실용적인 방법에 대해서 제안하고자 한다.

  • PDF

A 32${\times}$32-b Multiplier Using a New Method to Reduce a Compression Level of Partial Products (부분곱 압축단을 줄인 32${\times}$32 비트 곱셈기)

  • 홍상민;김병민;정인호;조태원
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.447-458
    • /
    • 2003
  • A high speed multiplier is essential basic building block for digital signal processors today. Typically iterative algorithms in Signal processing applications are realized which need a large number of multiply, add and accumulate operations. This paper describes a macro block of a parallel structured multiplier which has adopted a 32$\times$32-b regularly structured tree (RST). To improve the speed of the tree part, modified partial product generation method has been devised at architecture level. This reduces the 4 levels of compression stage to 3 levels, and propagation delay in Wallace tree structure by utilizing 4-2 compressor as well. Furthermore, this enables tree part to be combined with four modular block to construct a CSA tree (carry save adder tree). Therefore, combined with four modular block to construct a CSA tree (carry save adder tree). Therefore, multiplier architecture can be regularly laid out with same modules composed of Booth selectors, compressors and Modified Partial Product Generators (MPPG). At the circuit level new Booth selector with less transistors and encoder are proposed. The reduction in the number of transistors in Booth selector has a greater impact on the total transistor count. The transistor count of designed selector is 9 using PTL(Pass Transistor Logic). This reduces the transistor count by 50% as compared with that of the conventional one. The designed multiplier in 0.25${\mu}{\textrm}{m}$ technology, 2.5V, 1-poly and 5-metal CMOS process is simulated by Hspice and Epic. Delay is 4.2㎱ and average power consumes 1.81㎽/MHz. This result is far better than conventional multiplier with equal or better than the best one published.

Synthesis of Active Filers Using Linear Transformation (선형변환기법을 이용한 능동여파기의 구성에 관한 연구)

  • 이태원;조용현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.2
    • /
    • pp.41-51
    • /
    • 1983
  • An efficient method for the desist of active filters from doubly terminated lossless ladder type passive filters is presented. This technique is based on the linear transformation of network variables from the voltage-current domain to a new domain for the active realization of the passive networks. The method developed herein applies the linear transformation to a ladder building block which contains both a shunt and a series reactive arm, resulting in the minimization of the number of operational amplifiers required for the active realization. The validity and efficiency of this method are verified by the design of the 8th-order Chebyshev low-pass filter followed by the measurement of its frequency characteristics which fairly agree with the theoretic ones.

  • PDF

Constructing the Switching Function using Partition Techniques (분할 기법을 이용한 스위칭함수 구성)

  • Park, Chun-Myoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.793-794
    • /
    • 2011
  • This paper presents a method of the circuit design of the multiple-valued digital logic switching functions based on the modular techniques. Fisr of all, we introduce the necessity, background and concepts of the modular design techniques for the digital logic systems. Next, we discuss the definitions that are used in this paper. For the purpose of the circuit design for the multiple-valued digital logic switching functions, we discuss the extraction of the partition functions. Also we describe the construction method of the building block, that is called the modules, based on each partition functions. And we apply the proposed method to the example, we compare the results with the results of the earlier methods. In result, we decrease the control functions, it means that we obtain the effective cost in the digital logic design for any other earlier methods. In the future research, we require the universal module that traet more partition functions and more compact module.

  • PDF

Building Matching Analysis and New Building Update for the Integrated Use of the Digital Map and the Road Name Address Map (수치지도와 도로명주소지도의 통합 활용을 위한 건물 매칭 분석과 신규 건물 갱신)

  • Yeom, Jun Ho;Huh, Yong;Lee, Jeabin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.5
    • /
    • pp.459-467
    • /
    • 2014
  • The importance of fusion and association using established spatial information has increased gradually with the production and supply of various spatial data by public institutions. The generation of necessary spatial information without field investigation and additional surveying can reduce time, labor, and financial costs. However, the study of the integration of the newly introduced road name address map with the digital map is very insufficient. Even though the use of the road name address map is encouraged for public works related to spatial information, the digital map is still widely used because it is the national basic map. Therefore, in this study, building matching and update were performed to associate the digital map with the road name address map. After geometric calibration using the block-based ICP (Iterative Closest Point) method, multi-scale corresponding pair searching with hierarchical clustering was applied to detect the multi-type match. The accuracy assessment showed that the proposed method is more than 95% accurate and the matched building layer of the two maps is useful for the integrated application and fusion. In addition, the use of the road name address map, which carries the latest and most frequently renewed data, enables cost-effective updating of new buildings.

Development of Fire Detection Model for Underground Utility Facilities Using Deep Learning : Training Data Supplement and Bias Optimization (딥러닝 기반 지하공동구 화재 탐지 모델 개발 : 학습데이터 보강 및 편향 최적화)

  • Kim, Jeongsoo;Lee, Chan-Woo;Park, Seung-Hwa;Lee, Jong-Hyun;Hong, Chang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.320-330
    • /
    • 2020
  • Fire is difficult to achieve good performance in image detection using deep learning because of its high irregularity. In particular, there is little data on fire detection in underground utility facilities, which have poor light conditions and many objects similar to fire. These make fire detection challenging and cause low performance of deep learning models. Therefore, this study proposed a fire detection model using deep learning and estimated the performance of the model. The proposed model was designed using a combination of a basic convolutional neural network, Inception block of GoogleNet, and Skip connection of ResNet to optimize the deep learning model for fire detection under underground utility facilities. In addition, a training technique for the model was proposed. To examine the effectiveness of the method, the trained model was applied to fire images, which included fire and non-fire (which can be misunderstood as a fire) objects under the underground facilities or similar conditions, and results were analyzed. Metrics, such as precision and recall from deep learning models of other studies, were compared with those of the proposed model to estimate the model performance qualitatively. The results showed that the proposed model has high precision and recall for fire detection under low light intensity and both low erroneous and missing detection capabilities for things similar to fire.