• Title/Summary/Keyword: Building Use Type

Search Result 617, Processing Time 0.024 seconds

Selection of Priority for Revitalization by Analyzing Rural House Type (농촌주택 유형분석을 통한 재생우선순위 도출)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue;Bang, Se-Ra
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.174-175
    • /
    • 2014
  • A Rural house in Chungcheong area have been variety of matters, rapid deterioration of house and incomplete of maintenance control, that is represented lack of durability heating from lack of heat insulation property, health worsening form use of toxic substance and so on. For farmers who did not know where to repair and how to repair, they are urgently needed measures of standard and basis that is to realize a condition of rural house. Accordingly, this study drew major matters and priority for revitalization through analysis of type of rural house from research on the actual condition in order to develope of diagnostic criteria of rural house.

  • PDF

Effect that Practical Use of Typography gets in the Effectiveness of Advertisement in Printing Advertising (인쇄 광고에서 타이포그래피의 활용이 광고 효과에 미치는 영향)

  • Lee, Kwang-Sook;Kwak, Bo-Sun
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.1
    • /
    • pp.101-110
    • /
    • 2011
  • This research attempts to analyze type of typography influence on advertising attitude, brand attitude, and purchasing intention among print advertisements. Frequency analysis, reliability analysis using Cronbach's alpha, and MANOVA were utilized to analyze those gathered data. The result is the type of typography, affects on building advertising attitude in the mind of audience. However, brand attitude, and purchasing intention are not signigicant. It means that type of typography does not influence on building brand attitude and purchasing intention.

Analysis of Spatial Characteristics of Old Building Districts to Evaluate Fire Risk Factors (화재 위험요소의 도출을 위한 노후건축지구의 공간구성 특성분석)

  • Son, Byeung-Hun;Kang, Kyung-Ha;Ryu, Jung-Rim;Roh, Seung-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.69-80
    • /
    • 2022
  • The proportion of buildings over 30 years old in Korea has increased, from 29.0% in 2005 to 37.8% in 2019. These old buildings were built during a time in which there was a lack of building-related safety standards in areas such as fire safety performance. Worse, during their years of use, many such old buildings have had illegal changes and extensions made, making them more vulnerable in terms of safety. Fire safety investigations are being conducted to prevent large-scale disasters in multi-use buildings, but no investigation has been conducted at the regional district level, where small-scale old buildings are concentrated. Therefore, to identify fire risk factors in the old building district where old buildings are concentrated, the composition characteristics of the buildings were first analyzed. To examine the spatial characteristics of old building districts in order to derive fire risk factors, the results of this analysis based on the structure, use, roof type, and year of approval for use are as follows. It was found through our analysis that as of the date of approval for the use of the building, the main structure of the building has the greatest impact.

The study on the height standard and the slenderness ratio according to location types of Mixed-use Residential Tall buildings (초고층 주상복합건축물 입지유형에 따른 높이기준 및 세장비 제안에 관한 연구)

  • Sung, Lee-Yong;Kim, Yun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2779-2788
    • /
    • 2012
  • The housing market is now difficult because of excess of the increase rate of housing and long-term recession but high-rise mixed-use buildings can mix residential facilities with various demand facilities focusing and they have the advantages to secure open space and excellent view by high-rise apartment. But there are problems by hindrance of skyline formation and height of buildings. Therefore, the purpose of this study is to suggest the height standard and the slenderness ratio to location types of Mixed-use Residential Tall buildings. For the method of the study, term arrangement through literature search and the precedent research survey were first done, the level of urban design and the details related to the height of buildings were done as the case research focusing on the 16 cases in Seoul. The following results were drawn by suggesting the height standard and the slenderness ratio by location type based on them. First, the height of mixed-use building by location type in the level of urban design gets higher starting from the secondary center of the city and can be suggested as from less than 150m to more than 200m. Second, the slenderness ratio shall be planned as more than 1:3 because the area of the ground level of mixed-use building is large unlike Mixed-use Residential Tall buildings and visual passage shall be placed so that unity of openness and group formation will be planned. Third, for the height related to Mixed-use Residential Tall buildings, amendment of the special architectural district system and the special law related to super high-rise buildings shall be enacted.

Analysis on the Architectural Characteristics of Super High Rise Apartments (초고층 공동주택의 건축적 특성 분석)

  • Park, Hyeon-Ku;Song, Hyuk;Go, Seong-Seok
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.11-18
    • /
    • 2007
  • At the economical crisis of Korea in 1997, self-determined price for apartment and the revision increasing the ratio of residential area for mixed-use residential building were introduced to activate the construction industry, which causes construction companies to build super high rise apartment discriminative and high class orientated. This study aims to classify the super high rise building which is planned to build or built recently and to analyze the architectural characteristics. The objects are 288 unit households in 26 apartment complexes higher than twenty five story since 1998. As a result, super high rise building comparing with existing apartments were being varied in plan types of main building and unit household and in construction types. As for the plan, the number of walls having opening to outdoor were increased and it is considered that high rise building can take advantage of a view, lighting and sunshine. The location of living room that used to be in the center of unit in existing apartment was moved freely without rule.

Improvement Method for Management of Construction Sites' Workers (건설현장 인력시스템 관리 개선방안)

  • Hur, Jeonghyun;Kim, Gyu-Yong;Hur, Jaeyong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.159-160
    • /
    • 2023
  • Mainly, this research is consisted management of construction works. And this research is explained how make manage of workers health and methods of safety work in construction sites. As a result, writter researches to make ideas for manage to use that analyse each type of workers they are old workers, foreigner workers and general technicians.

  • PDF

The Effect of Combined Aggregates on Fluidity of the High Fluid Concrete Containing GGBFS (고로슬래그미분말을 혼입한 고유동콘크리트에서 골재조합이 콘크리트 유동성상에 미치는 영향에 관한 실험 연구)

  • Kim, Jae-Hun;Yoon, Sang-Chun;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.79-86
    • /
    • 2003
  • The purpose of study is to offer base data for high fluid concrete mix property, as grasp effect of aggregate to reach much more effect for producing high fluid concrete. For this study, there are three types of combined aggregates, river sand + river aggregate(type A), river sand + crusted aggregate(type B), washed sea sand + crushed aggregate(type C) and take a factor, water-contents, water-binder ratio and S/a. And so, we had following conclusion, resulting application-ability of high fluid mortar by K-slump tester to use a handy consistency measuring instrument. And so, we had following conclusion, resulting application-ability of high fluid concrete by K-slump tester to use a handy consistency measuring instrument. 1) In cafe of regular water binder ratio, high fluid concrete suffered much effect of combined aggregates and water binder ratio. Range of water binder ratio by combined aggregates is w/b 0.4 downward(type A and B), w/b 0.35 downward(type C). 2) Water contents to need for producing high fluid concrete is minimum 170kg/$\textrm{m}^3$ without regard to combined aggregates. 3) The effect of S/a on high fluid concrete by combined aggregates is approximately S/a 50% (type A and B), s/a 50-55% (type C). 4) Consistency measuring of high fluid concrete by K-slump tester is possible and first indication value, high fluid concrete can be produced, is 6~10.5cm.

A Study on the Energy Consumption Characteristics for Use and Operation Period in Office Buildings (업무용 건물의 용도 및 운전 기간별 에너지 소비 특성 연구)

  • Park, Byung Hun;Kim, Si Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.605-611
    • /
    • 2017
  • The purpose of this study is to calculate the energy consumption rate based on data regarding energy use in office buildings, and to confirm the general characteristics of energy consumption. The energy consumption rate of the building is calculated by dividing the energy consumption by the floor area. The energy consumption rate of small-sized office buildings was calculated as $101.48{\sim}201.55kWh/m^2{\cdot}year$ and in the case of medium-sized buildings, the range was $92.77{\sim}177.89kWh/m^2{\cdot}year$. In the case of small buildings, it was found that the energy consumption was $73.24kWh/m^2{\cdot}year$ in electronic device, $34.31kWh/m^2{\cdot}year$ in hot water supply, and $18.37kWh/m^2{\cdot}year$ in heating. In the case of medium-sized buildings, electronic devices was $73.08kWh/m^2{\cdot}year$, lighting was $18.35kWh/m^2{\cdot}year$ and heating, $15.37kWh/m^2{\cdot}year$. In all of the study buildings, the peak heating energy use was observed from 8:00 a.m. to 10:00 a.m during the winter, and the peak power management was required. Energy use at and around the midnight hour is confirmed to be 40~60% of weekly working hours, so it is necessary to manage power use at night time as well as during the day. In order to improve the accuracy of future studies, it is necessary to make efforts to secure the data with standardized energy measuring units for the various type of buildings.

A Comparative Study on the Horizontal Openness of High-rise Residential Buildings in terms of Building Arrangement Type - Focused on the Cases in Daegu - (상업지역 내 초고층 주거건축의 주동배치방식에 따른 수평적 개방성 비교연구 - 대구지역 사례 중심으로 -)

  • Kwon, Jong-Wook;Park, Sang-Min;Park, Byong-Han
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • Openness to outside is one of the most critical advantages for high-rise buildings. However, the effect of openness can be decreased if it is blocked by other high-rise buildings, especially built within the building complex of commercial district. The purpose of this study is to identify the horizontal openness of high-rise residential buildings by comparing 3 different cases of building arrangement type. A new method of evaluation has been introduced on the basis of distance to measure the openness including the matter of securing privacy. As a result of this study, comparative analysis was possible and relatively plentiful results of analysis could be drawn out. Through the process of analysis, this study set the evaluation indicators suitable to the analysis of openness of unit households. Thereby, the results of this study are expected to be used as useful basic data in planning high-rise mixed-use buildings.

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.