• Title/Summary/Keyword: Building Type

Search Result 3,426, Processing Time 0.036 seconds

A Study on Standard Heating and Cooling Load according to Design Factors using Prototypical Load Model (표준부하모델을 이용한 설계 변수에 따른 표준부하량 분석)

  • Kim, Kwonye;Bae, Sangmu;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • Before newly-built building and building remodeling, it is important to predict and analyze building energy performance through energy simulation programs. Nevertheless, simulation results widely vary depending on individual user experience and input values. Therefore, this study uses prototypical building model, a versatile tool in building energy modeling, simulation and research for researchers and policy-makers, and ASHRAE standards. Then, it analyzed the changes in design type (roof type, number of floors) for the base case. As the result, it was found that the gap of annual energy demand per between them is maximally 9.1%.

Construction Example on the Interior and Exterior of Building utilizing UHPC for Premix Type Room Temperature Curing (프리믹스형 상온양생용 UHPC를 활용한 건축물 내·외장 시공 사례)

  • Choi, Byung-Keol;Yoon, Ju-Yong;Ko, Hyo-Jin;Park, Yong-Kyu;Yoon, Gi-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.143-144
    • /
    • 2019
  • This study introduces the production and construction of building interior and exterior materials using UHPC for premix type room temperature curing developed through advance research and development.

  • PDF

A Study on analyze of energy saving rate by retrofitting multi air-conditioner from conventional type to high efficient type using Energyplus (Energyplus를 이용한 고효율 멀티에어컨디셔너의 에너지절감 효과 분석)

  • Seo, Jeongsik;Kim, Ook Joong;Woo, Juntae;Choi, Younsung;Jeon, Jongog
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.165.2-165.2
    • /
    • 2010
  • The objective of this study is to analyze the energy saving rate by retrofitting multi air conditioner from conventional type to high efficient type using Energyplus 4.0 which was developed for simulating a building energy by D.O.E. Generally, Multi air conditioner system was installed for both the cooling and the heating in a building. However, it was difficult to estimate the energy saving rate in the case of retrofitting multi air conditioner from conventional type to high efficient type. In the present study, annual energy consumptions of them were evaluated for same building and climate condition.

  • PDF

Dynamic Experiment of a Full-Scale Five-story Steel Building with Viscoelastic Dampers (점탄성 감쇠기가 설치된 실물크기 5층 철골건물의 진동실험)

  • 민경원;이영철;이상현;박민규;김두훈;박진일;정정교
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.239-246
    • /
    • 2002
  • Viscoelastic dampers are known effective devices for response reduction under earthquakes and winds. This study addresses how to design the optimum viscoelastic dampers installed at the full scale five-story steel building and novel approach to carry out the experimental work to verify the damper performance. First, an exciter of hybrid mass-type actuator is designed, which can move the building and its mathematical model is derived. The integrated system of building-actuator is experimentally analyzed for mathematical model. Second, convex model is applied for the prediction of required additional damping ratios to reduce responses below a specified target level. Chevron-type viscoelastic dampers are manufactured and installed at the first and second inter-stories, which are optimum places for response reduction. Sine-sweep and white noise excitations, which are generated by the hybrid mass-type actuator, are applied to the full scale building without and with dampers for performance verification. The transfer function of the building with four dampers, two of them installed at each first and second inter-story, are found to be lower than that of the building with two dampers installed at the first inter-story

  • PDF

Fragility Assessment of Damaged Piloti-Type RC Building With/Without BRB Under Successive Earthquakes (연속 지진에 의하여 손상된 필로티 RC 건축물의 BRB 보강 전/후의 취약성 평가)

  • Shin, Jiuk;Kim, JunHee;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.133-141
    • /
    • 2013
  • This paper presents the seismic evaluation and prediction of a damaged piloti-type Reinforced Concrete (RC) building before and after post-retrofitting under successive earthquakes. For considering realistic successive earthquakes, the past records measured at the same station were combined. In this study, the damaged RC building due to the first earthquake was retrofitted with a buckling-restrained brace (BRB) before the second earthquake occurred. Nonlinear Time History Analysis (NTHA) was performed under the scaled intensity of the successive ground motions. Based on the extensive structural response data obtained form from the NTHA, the fragility relationships between the ground shaking intensity and the probability of reaching a pre-determined limit state was were derived. In addition, The the fragility curves of the pre-damaged building without and with the BRBs were employed to evaluate the effect of the successive earthquakes and the post-retrofit effect. Through the seismic assessment subjected to the successive records, it was observed that the seismic performance of the pre-damaged building was significantly affected by the severity of the damage from the first earthquake damages and the hysteresis behavior of the retrofit element.

Analysis on Landscape Characteristic of Entrance Spaces in the Apartment Complex - A case study of 'Award of Good Apartment to Living' in the Capital Region - (공동주택 아파트 진입부 경관특성 연구 - 수도권 '살기좋은 아파트 수상'단지를 중심으로 -)

  • Lee, Gyeong-Jin;Lee, Gi-Woo
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.47-55
    • /
    • 2008
  • The purpose of this study is as follows. 1) An element to organize the landscape of an apartment entrance space and setting up, a characteristic of landscape through the actual condition analysis. 2) The characteristic of the type analysis and classified the shape of the entrance as the type. 3) The degree to like the landscape analysis through the making up question. The result of this research is as follows. The entrance of the apartment complex of 71 as of 92 and set an element to organize the landscape and the characteristic of landscape through the frequency analysis and divided an entrance landscape of apartment into 4 types through the cluster analysis. An entrance landscape of apartment types of the entrance is classified as follows. 1) Type I: A model wall-fence type, 2) Type II: The side constructing a building-fence type, 3) type III: The side constructing a building-retaining wall-mixing tree type, 4) type IV: The moulding constructing a building-a retaining wall type.

A Study on the Complex Effects of Streetscape Components on Visual Preference (도시가로경관요소가 시각적 선호에 미치는 복합적 영향에 관한 연구)

  • 변재상;정수정;임승빈
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.2
    • /
    • pp.9-18
    • /
    • 1999
  • In this study the relative effects among trees, cars, wires and building facades on visual preference are measured with the photo-montage scenes, which were synthesized by computer graphic programs. In addition to these experiments, the interaction of each elements of streetscapes have been investigated. The results of this study can be summarized as follows ; (1) It was found that trees had a remarkable positive effect on preference for streetscapes, wires had a moderate negative effect, cars had a trivial effect and the effects of building facades were medium. (2) It was investigated that the building of residential type was most preferred among commercial, residential, and office building types. The next preferred building facade was the commercial type. (3) The interaction of each element of streetscapes also have effects on preference. Especially, it was found that the combined effects of building-wire and building-cars were more notable than other combined effects of two elements.

  • PDF

Hydration property of Recycled Cement Using Waste Cementitious Powder (폐콘크리트 미분말을 이용하여 제조한 시멘트의 수화특성)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.47-48
    • /
    • 2014
  • This study is to hydration property of low carbon type recycled cement from waste cementitious powder and cement raw materials. Waste cementitious powder possible to low carbon type recycled cement in small part of additive materials. Also, low carbon type recycled cement using waste cementitious powder is suitable for low heat type cement.

  • PDF

Characters on building floor of Japanese elderly house (일본 유료 노인홈의 건물 내 층별 실구성의 특성)

  • Rhee, Ji-Sook
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.53-54
    • /
    • 2007
  • It is predicted that Japan will be in super-aged society at 2010. Recently elderly house buildings with self-supporting life and personal care senior house types have supplied over the area. So Elderly house buildings in Japan were studied for characters of room arrangement, through documents and internet from Jan. 2007 to Apr. 2007. Five cases built since 2000 were examined. There were self-supporting life house type, personal care senior house type, convenient facilities, etc. There were not lots of facilities in the building. Generally multi-purpose dining room and general bath room, lots for car and bicycle or restaurant or kindergarten or home helper station or green food shop or day service or moving service or clinic were there. These facilities were shared with local community. The reason of not being many facilities in the building was that the houses were located at urban with good transportation and convenient facilities. The residents in the building were get the utmost of regional facilities and the local people did the facilities in it because scare facilities in the building and fluent facilities in region. So strong community was composed of the residents and local people, on the contrary.

  • PDF

An Effect of the Change of Orientation and Window Area Ratio upon Building Energy Requirement in Apartment Housings (공동주택 향별 창면적비 변화에 따른 에너지 영향도 분석)

  • Kim, Jae Moon;Lee, Gyu Chul;Lee, Seung Gyu;Kim, Min Sung;Min, Joon Ki
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.21-26
    • /
    • 2013
  • Due to the increasing concerns about the buildings which have affected the global environment, most countries have enacted a regulation for the sustainability of domestic buildings. In 2008, the Korean government started to enact a regulation of apartment and office buildings for energy saving. Many research on the sustainable apartment building focuses on $84m^2$ or larger type in response to market demand; therefore, small size type such as $46m^2$ type needs to be researched. In addition, the research on the orientation and window to wall ratio of the building have been separately studied as a means of energy reduction; therefore, the research on correlation of the orientation and window to wall ratio hasn't been fully explored yet. This paper analyzes the energy demand of the apartment building as the change of orientation and window to wall ratio among $46m^2$ and $84m^2$ type. In conclusion, when reducing the window to wall ratio, energy demand was reduced, except when the orientation of the building was between from +10 to -20 from the south.