• Title/Summary/Keyword: Building Type

Search Result 3,408, Processing Time 0.028 seconds

A study of Library design through space program redefine -Gunpo city Library competition- (스페이스프로그램 재정의를 통한 도서관 계획연구 -군포시립도서관 현상설계-)

  • Yoon, Hwon;Lee, Ji-Eun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.8 no.2
    • /
    • pp.93-104
    • /
    • 2008
  • Purpose of this paper is to research about new building type of Korean library and suggest the design of Library which based on the building type changes. This research is based on the idea that change of building type could be derived from Architects' designs. So, we analyzed space programs of Gunpo Library competition, redefined the space programs and suggested the direction of building type changes with program changes through design processes. The conclusions of this research are follows; first, we suggested new zoning system in library building design that is consisted of three separate building based on each building's own functions. Second, new zoning and library design would be helpful to making plan about library building competition. The method that we tried at this projec is useful to other complex building designs which have necessities to redefine building type.

  • PDF

A Study on the Natural Period Estimation for the Buildings of Upper Wall and Lower Frame Type (상부벽식-하부골조를 가진 복합구조물의고유주기 산정에 관한 연구)

  • 박기수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.170-177
    • /
    • 1999
  • The natural period calculation equations specified in the current building code are empirical formulas that depend on height and material type of the structure. Building with the upper wall and lower frame type is a unique structure which composed of two different structural system This type of structure needs either the deep transfer girder or the thick transfer plate that brings the sudden change of stiffness and mass. Therefore the natural period equations recommended by the current code can not be applied directly. In this study the natural period of building with typical plan obtained by dynamci analysis is compared with that of various codes. Ad approximate estimation equation for the natural period of building with the upper wall and lower frame type obtained by regression analysis is recommended. by the current code can not be applied directly. In this study the natural period of building with typical plan obtained by dynamic analysis is compared with that of various codes, And approximate estimation equation for the natural period of building with the upper wall and lower frame type obtained by regression analysis is recommended.

  • PDF

Analysis the case study of tower type apartment by opening types of building surface (탑상형 아파트의 외피개방유형에 따른 전기에너지 사용량 사례 분석)

  • Kim, Yu-Won;Lee, Hyun-Soo;Kim, Eun-Hye
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.111-115
    • /
    • 2011
  • The purpose of this study was the analysis of electric energy consumption with the case study of tower type apartment's opening of building surface. We analyze the relationship between tower type apartment's opening of building surface and using electric energy consumption. The results of this study are: 1) The highest energy consumption of electric energy was on August without any influence of opening types of building surface. 2) Also, the south-west sides consumption of August was 848 kWh on Type B(one side opening) and it was the highest usage. 3) A house if facing west used more electricity than facing east when its opening of building surface's datum level is facing south. However, the house of facing east used more power than west when its opening of building surface's datum level is facing north. 4) When opening of building surface is facing on north-west or north-east, the opening of building surface's side of west and east used more electric power than north-west or north-east sides.

  • PDF

An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses- (건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 -)

  • Lee, Su-In;Kim, Jeong-Gook;Kim, Seo-Hun;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

Case Study on Landscape Defect Type of Defect Lawsuit in Apartment Building (공동주택 하자소송에서의 조경하자유형 사례분석)

  • Park, Jun-Mo;Seo, Deok-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.263-264
    • /
    • 2016
  • Since 2000s in Korea, apartment building tended to become goods or assets rather than houses. Therefore, conflicts between supplier and consumer were aggravated, and the defect dispute has been increased rapidly. This dispute enlarges to defect lawsuit and it is social and economical matter. The landscape work in apartment building is main work for a resident that appearance and convenient facility which lawn, tree, fountain, chair, playground, and etc. A number of defects surround landscape work are important issue in defect lawsuit, but, a related research is a minority, and a regulation is incomplete. Therefore, this study is basic study for standard of landscape defect type. As case study on defect lawsuit, draw a landscape defect type in apartment building.

  • PDF

An Analysis of Heating and Cooling Energy and Effect on Outdoor Air Cooling according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 및 외기냉방 효과 분석)

  • Roh, Ji-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.31-38
    • /
    • 2014
  • This study makes three apartment building complex an object of analyzing representative building types and energy consumption rate of house holds, and effect of outdoor air cooling. Recently created apatrment complex is composed of very various types of building, plan, and orientation etc. But, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively. Because architects are hard to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject is grasped, apartment building types were examined and representative types were extracted. In this study, energy simulation was conducted, and the effect to outdoor air cooling was analyzed about representative types of the subject apartment complex. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Besides solar gain, household layout of building, orientation, and plan etc. effects compositively on energy consumption rate. 2) The effect of ourdoor air cooling in building of tower type can be improved by arranging households appropriately.

A Comparative Study of Building Energy Simulations for Building Types in Multiple Stock Housing based on BIM(Building Information Modeling) (BIM기반의 공동주택 주동 유형별 건물에너지 시뮬레이션 비교에 관한 연구)

  • Lee, Byeongho;Lee, Geonwon;Yeo, Youngho
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.87-100
    • /
    • 2010
  • The energy efficient design of the multiple stock housing is very important not only to save energy but also to increase sustainability in a whole city because the multiple stock housing type is dominated in the major residential supply markets in Korea. During the early design phase of the multiple stock housing type, the architect need convenient and accurate tools for evaluating energy consumptions based on building types rapidly. Building Information Modeling(BIM) is introduced as useful tool systems providing interoperability between 3rd dimensional modeling tools and environmental engineering analysis tools, and could reduce time and cost for unnecessary modeling works in the analysis. However, it is still hard to apply to building design practice and integrated energy simulation techniques because interoperability using industrial standard file formats such as IFC and bXML is still underdeveloped. Therefore, the purpose of this study is to perform the building energy simulations, to compare the results on typical building types in multiple stock housing based on BIM, and to clear the problems using industrial standard file formats between 3rd dimensional modeling and building energy simulation software. In addition, through comparisons with simulation results according to the typical building types such as building forms, orientations, and building stories, the interrelation ship and characteristics of BIM based building energy simulation software are analysed and evaluated.

The Consciousness Research for Han-Ok Construction of Community Facilities in an Apartment Housing

  • Baek, Seung-Kwan;Kim, Young-Hoon
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.29-38
    • /
    • 2014
  • The Purpose of this study is to analyze the investigation of consumer's consciousness for Han-Ok construction of community facilities in an apartment housing. The contents of this study were largely composed of two parts; First was about concept and type of 'New Han-Ok type' public building. Second was about consciousness for Han-Ok construction of community facilities in an apartment housing. The result to this study is as following: 1) the concept of 'New Han-Ok type' public building should not only be defined in terms of cultural property or Han-Ok experience facilities but daily life and practical community. 2) the consciousness for Han-Ok construction of community facilities in an apartment housing was recognized affirmatively more than 75.9%. 3) the strengths of 'New Han-Ok type' public building was as following: daycare centers & small libraries & management office-use of eco materials, senior centers-traditional maintenance, community center-ease of daylight and ventilation. 4) Weaknesses of 'New Han-Ok type' public building was as following: daycare centers-security problem, senior centers-inconvenience of space, community facilities-inconvenience of facilities, small libraries-lack of storage space, management office-inconvenience of moving line. The conscious research for 'New Han-Ok type' public building should succeed for vitalizing for Han-Ok.

Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer (사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가)

  • Park, Su-Jin;Jung, Sun-Young;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire- (필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로-)

  • Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF