임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템 (Web-based Building Automation System using Embedded Linux)

  • 신은철;이수영;최병욱
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

입체·복합 프로젝트에서 발주자 중심의 WBS 구축방향 (An Establishment the Work Breakdown Structure for Owners in the Multi-Complex Project)

  • 고대준;최은아;서용칠;이상범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.127-131
    • /
    • 2008
  • The successful project management is based on definition of project goals in construction industry. The WBS(Work Breakdown Structure) is one of the major factors which defines works related to project goals. The necessity of the WBS for owners in multi complex projects which would help them to understand the whole project is rising because the multi-complex project in the construction industry has increasing recently. Therefore, this study suggests directions to establish the WBS for owners through investigating a concept of the multi-complex project first and analyzing types of project, domestic and foreign WBS, and case studies.

  • PDF

A comparison of three multi-objective evolutionary algorithms for optimal building design

  • Hong, Taehoon;Lee, Myeonghwi;Kim, Jimin;Koo, Choongwan;Jeong, Jaemin
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.656-657
    • /
    • 2015
  • Recently, Multi-Objective Optimization of design elements is an important issue in building design. Design variables that considering the specificities of the different environments should use the appropriate algorithm on optimization process. The purpose of this study is to compare and analyze the optimal solution using three evolutionary algorithms and energy modeling simulation. This paper consists of three steps: i)Developing three evolutionary algorithm model for optimization of design elements ; ii) Conducting Multi-Objective Optimization based on the developed model ; iii) Conducting comparative analysis of the optimal solution from each of the algorithms. Including Non-dominated Sorted Genetic Algorithm (NSGA-II), Multi-Objective Particle Swarm Optimization (MOPSO) and Random Search were used for optimization. Each algorithm showed similar range of result data. However, the execution speed of the optimization using the algorithm was shown a difference. NSGA-II showed the fastest execution speed. Moreover, the most optimal solution distribution is derived from NSGA-II.

  • PDF

다가구 매입임대주택의 입주자특성과 주거만족도 분석 - 대구광역시 사례를 중심으로 - (A Study On Residents' Satisfaction with Multi-family Public Rental Housing Program in Daegu)

  • 홍경구
    • 한국주거학회논문집
    • /
    • 제20권1호
    • /
    • pp.71-82
    • /
    • 2009
  • The purpose of our study is empirically to identify residents' satisfaction by multi-family public rental housing and to find out another improvement to solve the housing problems facing the poor in Daegu. As a new way of settling the housing problems for the poor in city, as you know, multi-family public rental housing program was introduced by the Korean government in 2004 but rarely empirically evaluated so far. in the Residents' Satisfaction, There are no evaluation of multi-family public rental housing program except Kim's study (2006). Based on 160 survey data, we evaluated the multi-family Public Rental Housing Program within the framework of affordability in economics, a satisfaction in building and in neighborhood by a statistical method. As a result, we find out that residents on multi-family Public Rental housing are satisfied with the multi-family Public Rental Housing Program by and large. For mitigating the housing and economic problem of the poor more, self-support program as well as assistance in housing are needed and multi-family Public Rental housing Program must include neighborhood program more.

조선시대 도성(都城) 중층건물의 건축형식 전개(展開)에 관한 연구 (A Study on the Architectural Evolution of Multi-storied Buildings in Hanyang, the Capital of Josun Dynasty)

  • 류성룡
    • 건축역사연구
    • /
    • 제24권3호
    • /
    • pp.17-29
    • /
    • 2015
  • This study is about the change of multi-storied buildings in Hanyang, the capital city of Joseon Dynasty. The changes are divided into 3 phases in the viewpoint of architectural types and building types. The first phase is from the early Joseon Dynasty to the time of Japanese invasion to Korea and Sungryemun remains until now. The second phase is from 1592 to the the first half of the 18th century. Many multi-storied Buddhist halls were rebuilt at that time. In the final phase, many multi-storied gate buildings and multi-storied main buildings of palaces were rebuilt. And there are differences between the Buddhist buildings and the main buildings of palaces. By the way the change that architectural style of the Buddhist buildings and the main buildings of pal were switched and mixed occurred. For example, Anguksa Daeungjeon adopted the style of multi-storied gates and Injeongjeon adopted the style of multi-storied Buddhist halls. These phenomenon was result from periodical situation the monk carpenter and his disciple took part in governmental construction like Janganmun.

Analysis of vortex induced vibration frequency of super tall building based on wind tunnel tests of MDOF aero-elastic model

  • Wang, Lei;Liang, Shuguo;Song, Jie;Wang, Shuliang
    • Wind and Structures
    • /
    • 제21권5호
    • /
    • pp.523-536
    • /
    • 2015
  • To study the vibration frequency of super high-rise buildings in the process of vortex induced vibration (VIV), wind tunnel tests of multi-degree-of-freedom (MDOF) aero-elastic models were carried out to measure the vibration frequency of the system directly. The effects of structural damping, wind field category, mass density, reduced wind velocity ($V_r$), as well as VIV displacement on the VIV frequency were investigated systematically. It was found that the frequency drift phenomenon cannot be ignored when the building is very high and flexible. When $V_r$ is less than 8, the drift magnitude of the frequency is typically positive. When $V_r$ is close to the critical wind velocity of resonance, the frequency drift magnitude becomes negative and reaches a minimum at the critical wind velocity. When $V_r$ is larger than12, the frequency drift magnitude almost maintains a stable value that is slightly smaller than the fundamental frequency of the aero-elastic model. Furthermore, the vibration frequency does not lock in the vortex shedding frequency completely, and it can even be significantly modified by the vortex shedding frequency when the reduced wind velocity is close to 10.5.

비선형 변위모드법을 적용한 복합구조물의 내진성능평가 (Evaluation of Seismic Performance of Mixed Building Structures by using the Nonlinear Displacement Mode Method)

  • 김부식;송호산
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.71-80
    • /
    • 2003
  • 구조물의 내진 성능을 정확히 평가하기 위해서는 비선형 시각 이력 해석이 필요하지만 실용성과 단순성 측면에서 약산법이 대안이 될 수 있으며, 다층 구조물을 등가 단자유도계로 치환할 때 다층 구조물의 모드벡터는 구조물이 탄성 또는 탄소성 상태에 상관없이 탄성 상태에서의 모드 형상으로 가정되지만, 항복이 발생한 후 증가하는 하중단계에서 구조물은 비탄성으로 되기 때문에 변위 모드 특성들도 변화된다. 본 논문은 항복 이후의 구조물의 모드 변화를 고려한 비선형 변위모드를 이용하여 다자유도계를 등가 단자유도계로 변환하는 방법을 제시하였으며, 변환된 등가 단자유도계의 변위응답을 근거로 추정한 복합 구조물의 최상층 변위와 실제 지진교란을 받는 복합 구조물의 비선형 동적해석에 의한 최상층 변위를 비교함으로서 복합구조물의 지진응답예측을 위한 비선형 변위모드법의 적용성과 신뢰성을 검토하였다.

수직적 도시 공동주거 커뮤니티에 적용된 공유공간의 계획특성 연구 -단위세대 경계부와 주거동 내부 및 경계부 영역을 중심으로- (A Study on the Design Characteristics of Communal Spaces in Vertical Urban Multi-Family Housing Community -Focused on the Territories of a Unit Boundary, Building Interior and Exterior Boundary-)

  • 조민정
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.55-67
    • /
    • 2011
  • The purpose of this research is to find applicable design characteristics and methods of communal spaces in vertical urban multi-family housing. With this goal, several overseas' multi-family housing projects are selected and their communal spaces are identified. The design characteristics of the communal spaces are analyzed with a special focus on the territories such as an individual unit boundary, building interior and exterior boundary. In terms of the framework for analysis, territoriality, openness, and unique characteristics are reviewed. As a result, the communal spaces are created using various spatial composition methods such as addition, subtraction, connection, extension, accumulation, and isolation. The communal space programs are integrated in plans and sections throughout the buildings. Visual openness and connection with surrounding urban environments are articulated by void spaces, transparent and translucent building materials, green spaces, and applications of graphical images. Communal identities and aesthetics are emphasized by unique building forms and space arrangements. The uses of finish materials, colors, objects, and images add strong characters to the communal spaces. For a further research, it is necessary to combine a design method study with residents' behaviors and community interactions.

High-rise Reinforced-concrete Building Incorporating an Oil Damper in an Outrigger Frame and Its Vibration Analysis

  • Omika, Yukihiro;Koshika, Norihide;Yamamoto, Yukimasa;Kawano, Kenichi;Shimizu, Kan
    • 국제초고층학회논문집
    • /
    • 제5권1호
    • /
    • pp.43-50
    • /
    • 2016
  • The reinforced-concrete multi-story shear-wall structure, which can free a building from beams and columns to allow the planning of a vast room, has increasingly been used in Japan as a high-rise reinforced-concrete structure. Since this structural system concentrates the seismic force onto multi-story shear walls inside, the bending deformation of the walls may cause excessive deformation on the upper floors during an earthquake. However, it is possible to control the bending deformation to within a certain level by setting high-strength and rigid beams (outriggers) at the top of the multi-story shear walls; these outriggers restrain the bending behavior of the walls. Moreover, it is possible to achieve high energy dissipation by placing vibration control devices on the outriggers and thus restrain the bending behavior. This paper outlines the earthquake response analysis of a high-rise residential tower to demonstrate the effectiveness of the outrigger frame incorporating vibration control devices.

다기능온돌시스템을 이용한 자연환기성능 평가 (Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System)

  • 조동우;유기형;유정연;정해권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF