• Title/Summary/Keyword: Building Maintenance Inspection

Search Result 336, Processing Time 0.029 seconds

Development of Framework for Asset Management of Public Building (공공건축물의 자산관리 프레임워크 개발)

  • Cho, Sang-Ouk;Ko, Kyu-Jin;Hwang, Jeong-Ha;Lee, Chan-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.133-142
    • /
    • 2015
  • The budget for public buildings is expected to increase to their maintenance, and the systematic maintenance and sufficient budget are recognized as the important factors for building maintenance. In Korea, buildings are not systematically maintained due to the lack of manpower, expertise and basis of maintenance budget estimates. Compared with Australia where the facility maintenance is optimized through asset management, Korea has only passive maintenance systems that focus on regulations. The introduction of the systematic asset management is required to ensure the advanced building maintenance in Korea. In this study, the asset management processes for social infrastructure facilities in and out of Korea were analyzed, and the asset management framework for public buildings were established. The asset management procedure consisted of ordinary asset management procedure, selective asset value assessment. The framework in this study was developed focusing on the asset management task for public buildings and presented the detailed contents of each step. The application of this framework to the actual work will enable the systematic management of building's value and performance, and the efficient appropriation of the maintenance budget.

A Study on the Analysis of Concrete Indurance Inspections Processes (IDEF0를 이용한 콘크리트 내구성 진단 프로세스 분석에 관한 연구)

  • Lee, Dong-Hun;Lee, Sang-Bum;Lim, Nam-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.113-120
    • /
    • 2005
  • The purpose of this study is to suggest a method of concrete safety inspection management system for safety inspection. this research investigates the process of building safety inspection with IDEF0(Integration DEFinition) process modeling method, focusing on concrete durability inspection, and then suggests a data management system, which allows user communications between site and related unit with RDBMS(Relational Database Management System). The suggested system is expected to provide more efficient data sharing tools and consequently improve safety inspection's quality.

Seismic Safety Assessment of Containment Building (격납건물의 내진안전성 평가)

  • Lee, Seong-Lo;Bae, Yong-Gwi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • In this study, the seismic safety of containment building is assessed using response surface method. The structural analyses considering random variables such as load, resistance and analysis by ABAQUS are performed to obtain the structural response. The structural response is represented by polynomial of random variables, and the reliability analysis is performed by Level II method. Drucker-Prager failure criterion is applied as limit state function to take bi-axial stress states into account in the concrete. The lifetime probability of failure is evaluated by considering the lifetime of containment building, the annual occurrence rate of earthquake and the conditional probability of failure. Also the sensitivity analysis on the selection of sampling points is performed to obtain the steady results from response surface method.

Seismic Isolation Effects According to Set up the Isolation Period in the Medium and Low-rise Framed Building (중.저층골조에서 면진주기 설정에 따른 면진효과)

  • Chun, Young-Soo;Hur, Moo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.93-99
    • /
    • 2010
  • Seismic isolation offers an attractive approach for reducing seismic loads in the building and its components. This paper deals with the seismic isolation effects due to variation in period ratio between superstructure and isolation layer of the building. Seismic isolation effects of the moment-resisting frames with the various period ratio were studied by nonlinear time history analysis, and the guidelines on the stiffness ratio of the superstructure and isolation layer of the building for the effective seismic isolation follow from the results of this study. It is recommended that the isolation period should be greater than 2.5 times of that of the superstructure for the effective seismic isolation.

A Study on the Improvement of Member Evaluation Method in the Condition Evaluation of Reinforced Concrete Buildings (철근콘크리트 건축물의 상태평가 중 부재평가방법 개선에 관한 연구)

  • Woo, Hye-Sung;Yi, Waon-Ho;Hwang, Kyung-Ran;Lee, Kwan-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.85-91
    • /
    • 2021
  • Type 1 and type 2 buildings must regularly conduct precise safety inspections and precise safety diagnosis for the safety and maintenance of facilities, and the safety grade of the building is determined according to the results of the implementation. In addition, the cycle of inspection and diagnosis is determined according to the safety grade of the building. In order to determine the safety grade of the building, a precise safety inspection conducts condition evaluation, and a precise safety diagnosis conducts condition evaluation and safety evaluation. Therefore, since the inspection and diagnosis cycle is determined according to the safety grade of the building, the condition evaluation and safety evaluation must be precise. However, in the case of member unit evaluation, which is the first step in evaluating the current condition, the evaluation grade is determined by using the representative value of the measurement result, and this may result in an error in the evaluation grade. To solve this problem, this study analyzed evaluation criteria for each evaluation item and presented evaluation criteria using inequalities to respond to measurement results and evaluation scores. In addition, we present a functional formula that can reflect performance scores for each evaluation item.

Development of Real-time Bridge Inspection Application connected with Bridge Management System (교량관리시스템과 연계된 실시간 교량 현장조사 프로그램 개발)

  • Park, Kyung-Hoon;Sun, Jong-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7893-7901
    • /
    • 2015
  • It is important to the periodic collection and analysis of the maintenance and management information of bridges for a more safe and efficient management of the bridges. To enhance the reliability and ease of acquisition of the bridge inspection information that is the basis for a strategy for safe and economic management using the bridge management system (BMS), this study develops a smart phone application for bridge inspection and ensures the actual applicability of the application. The developed application that is linked with the BMS for life-cycle management of bridges is possible to real-time query, modify and transmit of the maintenance-related information, and the application is able to greatly relieve the time and cost for the bridge inspection through the automatic creation of site inspection reports. The proposed method using the application is directly or indirectly expected to be very high effects of value improvement, such as ease of use, improved accuracy, sustainability of information, and future utilization, compared to conventional inspection method.

A Study on the Safety Management and Activation of Construction Remodeling (건축물 리모델링의 활성화 및 안전관리방안에 관한 연구)

  • Yang, Keek-Young;Kim, Chun-Hag
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.233-244
    • /
    • 2002
  • The purposes of this research are to use the buildings efficiently and long, save energies, make the cozy and comfortable environment of residential and living spaces, rearrange the related acts for easy implementation of remodeling, and activate the government's support programs so as to make remodeling activated in a safe mode. The scope and methodology of this research include the review of existing literatures and data on remodeling, census on apartment residents, influence factors, and the development of methods for activation of building remodeling and strengthening of safety management, like activation measures, licensing and ordering regulation updates, etc regarding the remodeling. Safety inspection and in-depth inspection before and after remodeling should be regulated. The construction materials for remodeling should be light weighted and the construction methods which can minimize the impact and vibration during construction should be selected. The improvement of regulation on the remodeling contractor qualification and order method should be updated. If the remodeling is activated and safety management is reinforced by the suggested measures, solving of lack of house, prevention of abuse of resources, and improvement of residential environment could be accomplished rationally.

Mitigating Seismic Response of the RC Framed Apartment Building Structures Using Stair-Installation Kagome Damping System (계단 설치형 카고메 감쇠시스템을 활용한 철근콘크리트 라멘조 공동주택의 지진응답 개선)

  • Hur, Moo-Won;Chun, Young-Soo;Lee, Sang-Hyun;Hwang, Jae-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.23-30
    • /
    • 2018
  • Recently, there are highly interests on structural damping to improve resistance of seismic and wind. It has been frequently used hysteresis damping devices made of steel because of economic efficiency, construction, and maintenance. This paper presents the effective reduction of seismic response by using Kagome damping system(SKDS) in rahmen system apartment building. The proposed system is designed to be activated by the relative displacement between the building and the stairs. It is performed nonlinear dynamic analysis to review the effects of earthquake response reduction for the 20-stories rahmen framed apartment building. In the analysis of the SKDS system, the reduction of maximum response displacement, maximum response acceleration and layer shear force are compared with the seismic design, and the result show that allowable story displacement is satisfied with Korean Building Code (KBC 2016).

Research on serviceability indicators and evaluation method for the revision of Special Act on Safety and maintenance of facilities (시특법 개정을 위한 서비스 성능 지표 설정 및 평가 방법 연구)

  • Park, Taeil;Park, Wonyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.312-313
    • /
    • 2018
  • As global climate change leaded to extensive natural disaster and radical deterioration of infrastructures, there was increased attentions for the evaluation of infrastructures. After the collapse of Seongsu Bridge in 1994, Korea has enacted the "Special act on safety and maintenance of facilities" and secured the safety of facilities using systematic and periodic safety inspections. However, current facility inspections are mainly performed by the physical defect and structural analysis, and do not properly consider the serviceability of infrastructure such as capacity of facility and user's satisfaction. Thus, the purpose of the study is to develop an evaluation criteria for serviceability of infrastructures and finally leading to the revision of "Special Act on safety and maintenance of facilities in rational manner.

  • PDF