• 제목/요약/키워드: Building Indoor Temperature

검색결과 284건 처리시간 0.048초

쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과 (Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof)

  • 송봉근;김경아;박경훈
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

전산유체역학을 이용한 디젤엔진 부하시험장의 환기 개선에 관한 연구 (A Study on the Ventilation Improvement of Diesel Locomotive Engine Load Test Building using Computational Fluid Dynamics)

  • 박덕신;정병철;조영민;박병현
    • 한국대기환경학회지
    • /
    • 제21권2호
    • /
    • pp.227-242
    • /
    • 2005
  • The aim of this study is to relieve the poor ventilation problem of the diesel locomotive engine load test building, located in an urban area. This paper evaluates the ventilation performances of the studied load test building based on the temperature measurement experiment and the computational fluid dynamics (CFD) during the engine load test. The temperature rise caused by the radiator blower of the building was turned out to be the main cause of disturbing the thermal conditions of the building. The indoor temperature distributions simulated by Fluent were validated with the temperature measurement results obtained from the studied building. The simulation results indicated that the comfort condition of this building was poor We suggested several remedial changes in the duct structure of this building for the improvement of the comfort conditions. In addition, a prototype drawing combining several improved design options was proposed. and then the simulation of the temperature distribution in the proposed prototype was performed. The result indicated that the indoor thermal condition of this proposed building was improved when compared with that of the current building.

Comparison of Hygrothermal Performance between Wood and Concrete Wall Structures using Simulation Program

  • Yu, Seulgi;Chang, Seong Jin;Kang, Yujin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권2호
    • /
    • pp.283-293
    • /
    • 2016
  • Owing to an increase in the air tightness of recent buildings, the natural ventilation rate was significantly lowered and the removal of accumulated moisture became difficult in these buildings. The hygrothermal performance of these buildings should be carefully considered to provide comfortable indoor environment by removing the moisture condensation risk and the mold growth potential. In this study, hygrothermal performance of two selected wall structures was investigated based on WUFI simulation program. The results displayed that the indoor temperature had impact on the moisture accumulation in the insulation layer for both modeled walls, showing that lower indoor temperature resulted in higher moisture accumulation, especially in the wood frame structure. Also, the yearly moisture accumulation profile exhibited a downward shift throughout the year by adding a vapour retarder with a lower sd-value. In addition, both of the two walls have condensation risk in winter, due to low temperature level. The wood frame structure has a bigger fluctuation and higher condensation risk than the concrete structure.

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

냉방시스템 제어구간설정 방법을 이용한 건물 실내온도 제어 (Building Indoor Temperature Control Using Control Horizon Method in Cooling Systems)

  • 부창진;김정혁;김호찬
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4902-4909
    • /
    • 2012
  • 본 논문에서는 TOU 요금제 기반에서 제어구간 설정방법을 사용한 건물 냉방시스템 실내온도 제어 알고리즘을 제안한다. 건물 실내온도를 최적제어하기 위한 제어구간 설정은 스위칭방법과 선형계획법을 사용하고 냉방시스템 사용요금은 TOU와 피크 요금을 포함하여 산정한다. 시뮬레이션을 통해 제안한 제어구간 설정방법을 적용하면 전력 사용에 따른 비용의 절감과 피크 전력 절감을 확인할 수 있다.

흙집의 하절기 실내 물리적 환경 특성과 온열감에 관한 연구 (A Study on the Indoor Climate Characteristics and Thermal Sensation Vote of the Earthen House in Summer Season)

  • 국찬;전지현;신용규
    • 한국주거학회논문집
    • /
    • 제17권5호
    • /
    • pp.9-16
    • /
    • 2006
  • The researches on the environmental friendly buildings have carried out on the materials, environmental property, technical elements and etc., and various buildings with these green materials have built and under construction nowadays and became a new trend of the green building. And recently, new building technique which builds the wall with the soil and wood and very easy to construct (called M Earthen House) was introduced as the green building and rapidly propagated. But the research on the indoor climatic characteristics, the ability to control the environmental comfort and the influence to the human beings of these buildings are not sufficiently identified yet. In this paper, the indoor environmental characteristics and the temperature controlling ability of these buildings in summer season were measured and analysed by the Portable Indoor Air Quality Monitor(BABUC/A, LSI) measuring equipments, ana the subjective test on the thermal environment of the subjects were carried out to evaluate the thermal comfort. The results can be summarized as follows; 1) Compared to the outdoor dry bulb temp.($15.4{\sim}28.7^{\circ}C$), the indoor temp. was $19.5{\sim}26.8^{\circ}C$. It showed the temperature controlling ability of the M earthen house was outstanding. And the indoor relative humidity, compared to the outdoor($45.4{\sim}100%$), was $58.1{\sim}76.4%$, it showed the humidity controlling ability of the M earthen house was also outstanding. 2) The thermal environment was evaluated as 'comfort'(neutral-slightly warm) and the humidity was also evaluated as 'comfort'(neutral-slightly humid). So, the results of the physical and subjective evaluation on the indoor thermal comfort in summer season were 'neutral' and 'comfort' coincidently, it was confirmed that the controlling ability of the indoor temperature and humidity of the M earthen house was very excellent.

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

건물 에너지 절감을 위한 실내 온도 추정 시스템 (Indoor Temperature Estimation System for Reduction of Building Energy Consumption)

  • 김정훈;유성현;이상수;김관수;안춘기
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2017년도 춘계학술발표대회
    • /
    • pp.885-888
    • /
    • 2017
  • In this paper, a new strategy for estimating building temperature based on the modified resistance capacitance (R - C) network thermal dynamic model is proposed. The proposed method gives accurate indoor temperature estimation using minimum variance finite impulse response filter. Our study is clarified by the experimental validation of the proposed indoor temperature estimation method. This experiment scenario environment is composed of a demand response (DR) server and home energy management system (HEMS) in a test bed.

바닥온도와 실내 환기에 따른 인체반응 및 실내공기질 분석 (An Analysis of Human Reaction & IAQ Analysis by Changing the Floor Temperature & Ventilation)

  • 이지원;진경일;김세환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.97-102
    • /
    • 2015
  • Recently many buildings are airtight, deterioration takes the high stage. As this room ventilation is increasingly difficult, the importance of indoor air was emphasized. And Got a few provisions on the indoor ventilation, the building is used for other purposes also requires a lot of careful research. In this study, consisting of floor heating ventilation in the room and wants to know the impact on the human body react with the carbon dioxide concentration in the indoor air were investigated PMV. We have get the data through the experimental study like this. It can be inferred correlations of ventilation and temperature according to human comfort that you should consider when using the work of residential buildings in accordance with the changing social conditions and social. It is also determined that in the future through additional experiments related data can be established basic experimental data.

제로카본 그린홈의 여름철 운영조건에 따른 실내 열환경 평가 (An Evaluation of Indoor Thermal Environment for Zero-Carbon Green Home according to the Operation Conditions in Summer)

  • 유정연;조동우;김기한
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.25-36
    • /
    • 2020
  • The Korean government has a plan to mandate zero-energy buildings in 2020 for public and 2025 for private buildings. In order to design a zero-energy building, insulation and airtightness, which are the most basic elements of passive house technology, are required, and the government has been accomplished this through step-by-step strengthening of related standards. In passive house with high thermal insulation and airtightness performance, the heat introduced into the building through solar radiation can be stored for a long time to keep the inside warm during winter. On the other hand, during summer, heat introduced into the building cannot be easily released to outside, so it is necessary to actively block solar radiation and high temperature outdoor air to prevent an increase of indoor temperature. Therefore, this study aims to derive an appropriate operation condition of passive house to maintain the indoor temperature at an suitable level according to the ventilation methods and solar shading conditions. As a result, under the conditions that the outdoor temperature was 28℃ or less, the ventilation using a heat recovery ventilation system at daytime and natural ventilation at nighttime were selected for the most appropriate operation method. In addition, in the case of solar shading, it was found that blocking solar radiation at daytime using the blind and open the blind at nighttime to ensure natural ventilation were selected for the most appropriate solar shading condition.