• Title/Summary/Keyword: Building Heights

Search Result 162, Processing Time 0.023 seconds

Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures (건축구조물의 내진성능 향상을 위한 강재댐퍼 형상 및 이력 거동)

  • Lee, Hyun-Ho;Kim, Seh-Il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.123-130
    • /
    • 2010
  • The aim of this paper is a seismic performance evaluation of metallic damper devices which are efficient in workability and installation process. For this V shape and S shape dampers is considered. The strut figures of dampers are V shape and S shape and, the research parameters are strut height and angle of the dampers. ABAQUS program is used for nonlinear finite element analysis. The analysis is performed with the hysteretic curve that has maximum displacement with 50mm and has increased progressive. As a results of evaluating the yield strength, maximum strength and energy dissipation capacity of each device, V and S shape have a good strength capacity and the devices with strut angle $60^{\circ}$ and strut height 140 and 200mm are evaluated stable in seismic behaviors. The response of S shape is more efficient than that of V shape. In the yield strength estimation process, proposed formula can not estimate the yield strength of V and S shape dampers. Even though, the formula can not consider the variation of strut heights and strut angles. Finally the S shape damper is recommended in seismic performance than V shape damper.

The use of cost-benefit analysis in performance-based earthquake engineering of steel structures

  • Ravanshadnia, Hamidreza;Shakib, Hamzeh;Ansari, Mokhtar;Safiey, Amir
    • Earthquakes and Structures
    • /
    • v.22 no.6
    • /
    • pp.561-570
    • /
    • 2022
  • It is of great importance to be able to evaluate different structural systems not only based on their seismic performance but also considering their lifetime service costs. Many structural systems exist that can meet the engineering requirements for different performance levels; therefore, these systems shall be selected based on their economic costs over time. In this paper, two structural systems, including special steel moment-resisting and the ordinary concentric braced frames, are considered, which are designed to meet the three performance levels: Immediate Occupancy (IO), Life Safety (LS), Collapse Prevention (CP). The seismic behavior of these two systems is studied under three strong ground motions (i.e., Tabas, Bam, Kajour earthquake records) using the Perform3D package, and the incurred damages to the studied systems are examined at two hazard levels. Economic analyses were performed to determine the most economical structural system to meet the specified performance level requirements, considering the initial cost and costs associated with damages of an earthquake that occurred during their lifetime. In essence, the economic lifetime study results show that the special moment-resisting frames at IO and LS performance levels are at least 20% more economical than braced frames. The result of the study for these building systems with different heights designed for different performance levels also shows it is more economical from the perspective of long-term ownership of the property to design for higher performance levels even though the initial construction cost is higher.

An experimental study on the behavior of the helical tiebacks in the flexible retaining walls

  • Majid Khanjani;Hamid Reza Saba;Seyed Hamid Lajevardi;Seyed Mohammad Mirhosseini;Ehsanollah Zeighami
    • Geomechanics and Engineering
    • /
    • v.36 no.6
    • /
    • pp.527-543
    • /
    • 2024
  • In the implementation of most civil structures, especially underground, deep excavations with a vertical slope are required. Using flexible retaining walls is applied as one of the ways to stabilize vertical holes. Therefore, it is necessary to know the parameters affecting the performance of such walls in reducing their horizontal movement. In this research, by building a suitable laboratory model, the parameters of the amount of flexibility, the embedment depth of the wall, the type and number of tieback in the wall were investigated for 42 static laboratory models. The purpose of this research is to study the flexible retaining wall with helical tieback compared to simple tieback at different heights, which shows the best performance in terms of reducing horizontal displacement in proportion to increasing or decreasing flexibility. On the other hand, one of the parameters affecting the flexibility of the wall, which is its bending stiffness, was extracted by numerical software outputs and studied on the results such as relative flexibility, stiffness, safety and numerical stability of the wall.The results of this study show that among the parameters, in the first place, the effect of the type of tieback is inhibited and in the second place, the ratio of thickness to wall height is known as the most important parameter. the best performance for walls with the helical tiebacks in reducing their horizontal displacement can be economically, flexibly and stability assigned to a wall that tiebacks is in the range of H2/t to H4/t and its flexibility ratio is 2/3.

Floor Impact Noise Characteristics Depending on the Experimental Conditions Using Impact Ball (실험조건에 따른 임팩트 볼의 바닥충격음 변화 고찰)

  • Lee, Won-Hak;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.92-99
    • /
    • 2011
  • In Japan, bang machine has been considered to have problems about not only the impact force and frequency response which are different from the real impact sources such as children's jumping and running, but also damage in the wooden structure housing. Therefore, a new impactor for lower impact force to prevent demage in wooden structure housing was developed. The impact ball was adopted as the second standard impact source in JIS A 1418-2 and ISO 140-11. In the present study, floor impact sounds generated by impact ball with drop heights in four floors of mock-up building of Building Research Institute (BRI) similar to typical Japanese wooden structure housing were investigated and also compared to jumping sound. The results show that Impact ball sound dropped at 10 cm to 30 cm was most similar to jumping sound. And The impact sound levels at 250 and 500 Hz were more sensitive to drop height than other lower frequencies. The error that may occur from the difference of height of 10 cm up and down based on the standard drop height caused by the impact ball operated by human hands was approx. 1 dB or less only in its value of characteristic, but it must be carefully taken into Impact ball in the Korea Standard.

Constructing Topographies of EMF Risks from Underground Power Lines (전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로)

  • Kim, JooHui
    • Journal of Science and Technology Studies
    • /
    • v.19 no.3
    • /
    • pp.119-166
    • /
    • 2019
  • The risk of electromagnetic field(EMF) from power lines has been heavily disputed whenever high-voltage power line towers were built in South Korea. Local communities and civic groups had regarded burying the lines in the ground as an alternative to building power line towers. In 2014, however, when an elementary school science teacher reported the results of EMF measurements over the underground power lines to the Asian Citizens' Center for Environment and Health (ACCEH), the risk controversy over underground power lines took a whole new turn. The level of EMF from underground power lines turned out to be higher, and therefore more harmful than that from power line towers. In the debates that took place from then on over the EMF risk, ACCEH and NIER(National Institute of Environmental Research) presented conflicting topographies of EMF risk. This paper examines measuring practices of ACCEH and NIER by analyzing the measuring sites, measuring devices, and measuring heights chosen by each organization. This paper further examines how ACCEH and NIER mobilized various standards(EMF exposure limit, measurement guideline, categorization of carcinogens) differently. This controversy on the EMF from underground power lines of Seoul has raised concerns on the non-thermal effects of EMF in the long-term exposure and has led people to question whether burying the power lines is the safe alternative to building power line towers. Furthermore, this suggests conflicting answers on whether Seoul, where 90 % of transmission lines were already buried, is a safely managed place or not.

Experimental Assessment and Specimen Height Effect in Frost Heave Testing Apparatus (동상시험장비의 실험적 검증 및 시료크기의 영향에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Frost heave is one of the representative engineering characteristics in cold regions. In South Korea, which is located in seasonal frost area, structural damage caused by frost heave and thaw happens and the need for research on the frost heave is increasing. In this paper, newly developed transparent temperature-controllable cell is used to focus on the frost heave. Frost susceptible artificial soil is used to analyze water intake rate which is one of the important factors in frost susceptibility criteria. Frost heave rate and water intake rate have similar behavior after heave by freezing of pore water converges. O-ring installed in the upper pedestal to measure water intake rate generates side friction between the inner wall of the freezing cell and O-ring, thereby hindering frost heave. Therefore, the frost susceptibility criteria using the water intake rate is not reliable. It is appropriate to use frost heave rate which has similar behavior with water intake rate. Frost heave tests were performed under two different specimen heights. Overburden pressure, temperature gradient and dry unit weight were set under similar state. Based on laboratory testing results, frost heave is independent on the specimen height.

Electromagnetic Wave in all Base Stations (다기지국 환경에서 전자파 노출량)

  • Cho, Euy-Hyun;Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.26-44
    • /
    • 2011
  • The Study was carreid out to see whether the intensity of electromagnetic waves in each floor of a building where the sharing base station has been established is harmful to a human body, and to expect the intensity of the waves in the building. The investigate was performed on both of sharing base station either with many scatterers or without any of them. To satisfy the international standard and the domestic TTA standard, rms for each of the electromagnetic wave of every floor in the building with the station was measured from 3 location of 3 heights(1.1m,1.5m, and 1.7m). Max of the measured rsm from the each of the frequencies in the nine location was confirmed to be 48.12%(the rooftop measured value) at most, compared to the human body protection standard. The value was confirmed to satisfy the human body protection standard for each frequency. And the total value of the calculated exposure indexes for each frequency was determined to be more than 7 times lower at most, which was 0.1445, compared to the 1 standard. Since P value in both of 868MHz and 2.14GHz electromagnetic waves intensity for each base station and floor was less than 0.05, it was revealed to be meaningful, and since R-Sq(adj) value showed a value more than 50%, the regression equation was determined to fully absorb the data information. However, although the P value of both of 868MHz and 2.14GHz electromagnetic waves intensities under the integrating terms of the base station data and the floor data was showed to be less than 0,05, since R-Sq(adj) value of 868MHz electromagnetic waves intensity presented a value smaller than 50%(34.15%), it was determined that the 868MHz electromagnetic waves intensity is very much influenced by an environment with a base station. Because the electromagnetic waves intensity of 2.14GHz show R-Sq(adj) value bigger then 50%(51.8%), The regression equation model of 2.14GHz electromagnetic waves intensity was confirmed to be proper. It also turned out not to be effected by the surrounding environment near a building with the base station and the intensity of electromagnetic waves for each floor of such building was expectable by the regression equation.

Practical Strategies for Urban Regeneration through an Application of Landscape Urbanism (랜드스케이프 어바니즘 관점에서 본 도시재생 전략 연구)

  • Cho, Se-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • This study aims to propose practical strategies for the new urban ideal of regeneration. A book review highlights the emergence of new trends of urbanization in knowledge-information industrial society beyond the new town Ideal of the industrial society. The meaning of ‘landscape’ in landscape urbanism represents not the visual and decorative pictures, but the dynamic process in the context of changes and evolutions. Also, knowledge-information industrial society and landscape have a meaning in the same context of flow and process with changes of velocity. Finally, these key words convey a meaning with the new urban trends of urbanization in knowledge-information industrial society in the context of value-oriented characteristics of dynamics and process. Urban regeneration is emerging as the new urban ideal in the knowledge-information industrial society, beyond the new town ideal of industrial society. It is in the same context as landscape urbanism with respect to green infrastructure buildings and designs for the transformation of urban surfaces covered with concrete and asphalt into the ecological surface, and of the ecological surfaces into the cultural surface that could be communicated with human beings. This research revealed the six strategies for urban regeneration as follows. The First, the strategies for the transformation of urban surfaces into ecological surfaces, the second, the strategies for the transformation of ecological surfaces into cultural surfaces, the third, the introduction of mixed and convergence land use, the forth, the transformation of former sites(e.g. military and factory) into urban parks, the fifth, the introduction of waterfront park zones that have the function of ecological and park-oriented mixed land use and, the sixth, the building and design of green infrastructure in the residential and commercial complex in CBD. These strategies call for the reforms of development laws and regulations to restrict building coverage ratio, building heights, and the introduction of park-oriented mixed zoning regulations. Another method for implementating the above listed strategies was the introduction of a strategic planning system instead of the traditional master plan system. This system uses a value planning approach and brand making by imagery. It is able to construct the meaning of an image and its creativeness directly.

Estimation of Topographic Effects over 3-Dimensional Hills with Different Slopes through Wind Tunnel Tests (경사가 다른 3차원 산악지형에서의 풍동실험을 통한 풍속할증평가)

  • Cho, Kang-Pyo;Cheong, Myung-Chae;Cho, Gi-Sung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.379-386
    • /
    • 2007
  • In this paper, topographic factors over 3-dimensional hills were estimated through wind tunnel tests. Topographic models having five different slopes of $5.71^{\circ}, \;11.31^{\circ},\;16.70^{\circ},\;21.80^{\circ}$, and $26.57^{\circ}$ which were based on Korean Building Code(KBC(2005), were made for wind tunnel tests. From the result of wind tunnel tests, topographic factors over 3-dimensional hills were obtained at various locations, and the ranges of topographic effects were decided. The ranges of topographic effects was whole area of the hills in the horizontal ranges and heights of 3.5 times of the hills in the vortical ranges. Topographic effects was large at the top of hills, and wind velocity was increased 57% over hill of $5.71^{\circ}$, 75% over hill of $11.31^{\circ}$, 79% over hill of $16.70^{\circ}$, 81% over hill of $21.80^{\circ}$, and 61% over hill of $26.57^{\circ}$. Wind velocity was bigger over surface of across-wind direction of hills than one over surface of wind direction of hills, and wind velocity was increased $10{\sim}30%$ at locations of across-wind direction.

Assessment of Equivalent Heights of Soil for the Lateral Earth Pressure Against Retaining Walls Due to Design Truck Load by 3D Numerical Analysis (3차원 수치해석에 의한 표준트럭하중에 의해 옹벽에 작용하는 수평토압의 등가높이 산정)

  • Seo, Seunghwan;Jin, Hyunsik;Kim, Dongwook;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.75-85
    • /
    • 2019
  • The lateral load from traffic depends on standard truck's axle loads and locations, loading distance from the inner wall. The method of limit state design has been adopted and used for design of roads in the Republic of Korea since 2015. The concept of equivalent height of soil accounting for traffic loading is often used for design of retaining walls to quantify the traffic loads transmitted to the inner wall faces. Due to the different characteristics of the standard design trucks between Korea and US (AASHTO), the direct use of the guidelines from AASHTO LRFD leads to incorrect estimation of traffic load effects on retaining walls. This paper presents the results of evaluation of equivalent height of soil to reflect the standard truck of the nation, based on the findings from analytical solutions using 3D finite element method. Compare to US, the standard truck loading has a structure where the axle load is concentrated so that the equivalent load height is estimated to be slightly larger than AASHTO for lower retaining wall height. It would be reasonable to present the equivalent load height in Korea more conservatively than AASHTO in terms of securing long term stability of the retaining wall structure.