• 제목/요약/키워드: Building Energy Modeling and Analysis

검색결과 95건 처리시간 0.028초

Additive 2D and 3D performance ratio analysis for steel outrigger alternative design

  • Lee, Dongkyu
    • Steel and Composite Structures
    • /
    • 제20권5호
    • /
    • pp.1133-1153
    • /
    • 2016
  • In this article, an additive performance ratio method using structural analysis of both 2D and 3D is introduced to mitigate the complexity of work evaluating structural performances of numerous steel outrigger alternatives in multi-story buildings, especially high-rise buildings. The combined structural analysis process enables to be the design of economic, safe, and as constructional demanding structures by exploiting the advantages of steel, namely: excellent energy dissipation and ductility. First the approach decides the alternative of numerous steel outriggers by a simple 2D analysis module and then the alternative is evaluated by 3D analysis module. Initial structural analyses of outrigger types are carried out through MIDAS Gen 2D modeling, approximately, and then the results appeal structural performance and lead to decide some alternative of outrigger types. ETABS 3D modeling is used with respect to realization and evaluation of exact structural behaviors. The approach reduces computational burden in compared to existing concepts such as full 3D analysis methods. The combined 2D and 3D tools are verified by cycle and displacement tests including comprehensive nonlinear dynamic simulations. The advantages and limitations of the Additive Performance Ratio Approach are highlighted in a case study on a high rise steel-composite building, which targets at designing the optimized alternative to the existing original outrigger for lateral load resisting system.

BIM기반 건축물 설계 과정에서 실시간 에너지 성능 분석을 위한 기술 개발에 관한 연구 - 열관류율 분석을 중심으로 (A Study on the Development of the Technology of Evaluating the Performance of Energy - saving in the BIM-based Design Process in the Real Time Manner Focused on the Analysis of Coefficient of Overall Heat Transmission)

  • 이윤길;조원준
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.29-37
    • /
    • 2013
  • This study intended to introduce the method of designing an eco-friendly building based on BIM(Building Information Modeling) and BIM-based application. The proposed application aimed to generate the environmental performance of the designed alternative automatically in real-time manner in the process of architectural design. We focused on the feasibility of BIM-based eco-friendly design process and the applicability of the developed application for the architectural design practice. In this manner, in the end of paper, we proposed the so-call EcoBIM which is the performance evaluation module for the designed alternative using BIM in the real-time manner and the new design process with it. EcoBIM generate the coefficient of overall heat transmission of wall, roof and slab of the designed alternative with their physical characteristics such as thickness, thermal resistance and so on.

공동주택의 판상형과 타워형 에너지 성능 비교 분석 (Energy Performance Analysis the Common House Pansang Type and Tower)

  • 윤성민;이경희;안영철
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.57-64
    • /
    • 2013
  • This study focus on the analysis of the energy performance in accordance with apartment houses arrangement type by using Ecotect Analysis. Korea, energy-poor country, the rate of dependence on imports amount to 94%, have to reduce energy consumption part of building except in industry and transport which affect the economic. Apartment houses are built in various forms in order to reduce energy, are modelled in each window area ratio, shape, orientation, climate through simulation. Through this study, we can analyze energy performance by form, window area ratio, orientation, climate change and know the optimal elements by the form. In particular, although there have been studied research on the window area ratio and research related to the arrangement form, determined that the information on the regional climate characteristics and the direction of placement is less than existing research. To supplement those problem, adding to seven direction(West, S-60-W, S-30-W, South, S-30-E, S-60-E, East) and climatic element(southern region) is characteristic of this study. The form of apartment houses was modelled for apartment houses built in the 10 years since. And each modeling were analyzed by Ecotect Analysis.

Beehive (Hexagrid), New Innovated Structural System for Tall Buildings

  • Nejad, Peyman Askari
    • 국제초고층학회논문집
    • /
    • 제5권4호
    • /
    • pp.251-262
    • /
    • 2016
  • Tall Buildings have been one of the most prominent symbols of economic growth for nearly a century. Yet, in the aftermath of the tragedies of September 11, "signature" Tall buildings have become the focus of much debate. The structural systems today are undergoing a major evolution to address the ability of providing flexibility in the design and use of the building together with sustainability (Green) and cost-effective system. This paper describes a new invented structural system, evolutionary structural analysis and design of Tall buildings, which involves the entire analysis process, including conceptual and design stages and comparison with the existing Tall building. This study presents an new innovative structural system, Beehive (Hexagrid), for Tall buildings. The final results are achieved by modeling an 80 story Tall building with the optimized angle and topology of hexagon members by using a computer analysis, ETABS finite element analysis. The objective function of this system is to use one structural system in order to both maximize Eigen frequency for resisting dynamic responses and minimize mean compliance for static responses. Finite element analysis is carried out by using standardized materials. Optimal Hexagrid topologies with the highest stiffness are finally determined to resist both static and dynamic behaviors. Holistic design integration approaches between structures and facades to save energy for environmental control are studied. Innovative design ideas to control structural motion as well as to utilize that motion to harness energy are discussed. Considering abundant emergence of tall buildings all over the world in recent years, the importance of the studies presented in this paper cannot be overemphasized for constructing more sustainable built environments.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Prototype Development for BIM based Thermal Insulation and Condensation Performance Evaluation of Apartment Housings

  • Oh, Hyangok;Cho, Daegu;Jang, Hyang-In;Hong, Soungwook;Lee, Myung Sik
    • Architectural research
    • /
    • 제17권2호
    • /
    • pp.75-81
    • /
    • 2015
  • Insulation and condensation performance evaluation (I&CPE) is an important energy analysis. While considerable amount of data are already represented in a Building Information Model (BIM), the lack of interoperability between BIM modeling and I&CPE programs prevents the simulation process from being efficient and accurate. This study proposes a prototype of a BIM-based I&CPE simulation program, in order to enhance the interoperability between BIM modeling and I&CPE programs. This study discusses the information flow process, defines the required information and its level of detail, develops standardized libraries, and finally proposes a prototype that consists of a data extraction module, conversion module, and performance module. The assurance of interoperability between systems might greatly benefit architects and energy professionals.

태양열을 이용하는 잠열축열 시스템에 관한 연구(제1보 PCM 계산 모델의 개발) (A Study on latent heat storage system with Solar heat(Part 1. Development of PCM modeling))

  • 구학근;김종열
    • 한국태양에너지학회 논문집
    • /
    • 제21권4호
    • /
    • pp.47-54
    • /
    • 2001
  • This study has been conducted to verify the possibility of adaptation of a latent storage type air-conditioning system, shifting the peak load of electronic power to a building. In this paper, an energy equation to evaluate performance of PEM(phase change material) has been suggested and solved, after discretization. As a result, it is confirmed that the results from the energy equation are correspond with those from present studies to analysis of one-dimensional solidification and to analysis of two-dimensional solidification.

  • PDF

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

A Study of Neutronics Effects of the Spacer Grids in a Typical PWR via Monte Carlo Calculation

  • Tran, Xuan Bach;Cho, Nam Zin
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.33-42
    • /
    • 2016
  • Spacer grids play an important role in maintaining the proper form of the fuel assembly structure and ensuring the safety of reactor core design. This study applies the Monte Carlo method to the analysis of the neutronics effects of spacer grids in a typical pressurized water reactor (PWR). The core problem used to analyze the neutronics effects of spacer grids is a modified version of Korea Advanced Institute of Science and Technology benchmark problem 1B, based on an Advanced Power Reactor 1400 (APR1400) core model. The spacer grids are modeled and added to this test problem in various ways. Then, by running MCNP5 for all cases of spacer grid modeling, some important numerical results, such as the effective multiplication factor, the spatial distributions of neutron flux, and its energy spectrum are obtained. The numerical results of each case of spacer grid modeling are analyzed and compared to assess which type has more advantages in accuracy of numerical results and effectiveness in terms of geometry building. The conclusion is that the most realistic modeling for Monte Carlo calculation is the "volume-preserving" streamlined heterogeneous spacer grids, but the "banded" dissolution spacer grids modeling is a more practical yet accurate model for routine (deterministic) analysis.