• Title/Summary/Keyword: Building Effect

Search Result 3,952, Processing Time 0.035 seconds

A Review on Building-Integrated Wind Turbine Design (건물 일체형 풍력시스템 디자인 고찰)

  • Kim, Yong-Yee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.64-69
    • /
    • 2011
  • Integrating wind energy systems into building design is a small but growing trend, and high riese with their elevated wind speeds seem particularly suited to the technology. This paper deal with building-integrated wind turbine design. It thus contains two topics: wind energy and building design. Several building-integerated wind turbine design have been categorized and reviewed.

A Study on the Usefulness of the Countermeasures locally for the stack-effect in High-rise building (국소적 연돌효과 저감대책의 효용성에 관한 연구)

  • Seo, Jung-Min;Lim, Hyun-Woo;Lee, June-Ho;Lee, Joong-Hoon;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.300-305
    • /
    • 2009
  • High-rise buildings have some problems by stack effect. And, the solutions on the problems should be determined by considering an overall building. But, ordinarily, the countermeasures on the problems are applied to local part of the building. Local countermeasures often can be possible to arouse the secondary problems accompanied by the stack-effect. In this study, the usefulness of local countermeasures are evaluated in terms of both the reduction effect on problems and the possible secondary problems with simulations. The simulation results show that the application of countermeasures on an overall building is very important and that local countermeasures can be used optionally according to building's conditions.

  • PDF

An Analysis of the Effect of Weather Condition with Work Sections in Building Construction (건축공사 공종별 기후요소 영향도 분석)

  • Kim Baek-Joong;Seo Jang-Woo;Kang Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.141-144
    • /
    • 2006
  • The building construction is an essential field to consider weather condition because construction works are performed in a site. From this reason, this study evaluated the effect of weather condition with work sections in building construction by Analytic Hierarchy Proces (AHP) method. The results of this study as follows : (1) The effect of weather condition with work sections is affected by rainfall in summer season, and by a low temperature in winter season (2) The effect of weather condition with work sections is 0.235 for mold work, 0.210 for concrete work, 0.181 for steel-frame work.

  • PDF

An Analysis of Heating and Cooling Energy and Effect on Outdoor Air Cooling according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 및 외기냉방 효과 분석)

  • Roh, Ji-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.31-38
    • /
    • 2014
  • This study makes three apartment building complex an object of analyzing representative building types and energy consumption rate of house holds, and effect of outdoor air cooling. Recently created apatrment complex is composed of very various types of building, plan, and orientation etc. But, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively. Because architects are hard to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject is grasped, apartment building types were examined and representative types were extracted. In this study, energy simulation was conducted, and the effect to outdoor air cooling was analyzed about representative types of the subject apartment complex. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Besides solar gain, household layout of building, orientation, and plan etc. effects compositively on energy consumption rate. 2) The effect of ourdoor air cooling in building of tower type can be improved by arranging households appropriately.

A Study on the Complex Effects of Streetscape Components on Visual Preference (도시가로경관요소가 시각적 선호에 미치는 복합적 영향에 관한 연구)

  • 변재상;정수정;임승빈
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.2
    • /
    • pp.9-18
    • /
    • 1999
  • In this study the relative effects among trees, cars, wires and building facades on visual preference are measured with the photo-montage scenes, which were synthesized by computer graphic programs. In addition to these experiments, the interaction of each elements of streetscapes have been investigated. The results of this study can be summarized as follows ; (1) It was found that trees had a remarkable positive effect on preference for streetscapes, wires had a moderate negative effect, cars had a trivial effect and the effects of building facades were medium. (2) It was investigated that the building of residential type was most preferred among commercial, residential, and office building types. The next preferred building facade was the commercial type. (3) The interaction of each element of streetscapes also have effects on preference. Especially, it was found that the combined effects of building-wire and building-cars were more notable than other combined effects of two elements.

  • PDF

A Basical Study about Ventilation Performance of Natural Smoke Ventilators through Stack Effect in High-rise Building (고층건축물에서의 연돌효과에 따른 배연창의 배연성능에 관한 기초적 연구)

  • Kim, Hye-Won;Jin, Seung-Hyun;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.54-55
    • /
    • 2017
  • The High-rise building has a problem the ventilation performance of natural ventilator by stack effect that it occurs by pressure difference. For that reason the study about natural smoke ventilator of High-rise building consistently needs. Therefore on this study does analysis of difference with abroad through investigate of Natrual smoke ventilator's law, it conducts of natural smoke ventilator's research on the actual condition. As a result on this study, in the case of abroad that it states more specific standards than domestic. Also the result of a field study, it shows that the natural smoke ventilator is installed same size and the number regardless of building's pressure difference.

  • PDF

Interference effects in a group of tall buildings closely arranged in an L- or T-shaped pattern

  • Zhao, J.G.;Lam, K.M.
    • Wind and Structures
    • /
    • v.11 no.1
    • /
    • pp.1-18
    • /
    • 2008
  • Interference effects in five square tall buildings arranged in an L- or T-shaped pattern are investigated in the wind tunnel. Mean and fluctuating shear forces, overturning moments and torsional moment are measured on each building with a force balance mounted at its base. Results are obtained at two values of clear separation between adjacent buildings, at half and a quarter building breadth. It is found that strong interference effect exists on all member buildings, resulting in significant modifications of wind loads as compared with the isolated single building case. Sheltering effect is observed on wind loads acting along the direction of an arm of the "L" or "T" on the inner buildings. However, increase in these wind loads from the isolated single building case is found on the most upwind edge building in the arm when wind blows at a slight oblique angle to the arm. The corner formed by two arms of buildings results in some wind catchment effect leading to increased wind pressure on windward building faces. Interesting interference phenomena such as negative drag force are reported. Interference effects on wind load fluctuations, load spectra and dynamic building responses are also studied and discussed.

The Effects of Early Childhood Teachers' Civic Consciousness on Actions for Building an Community: The Mediating Effect of Innovative Culture (유아교사의 시민의식이 공동체 구현 실천 행동에 미치는 영향에서 혁신문화의 매개 효과)

  • Chung, Kai Sook;Noh, Jin Hyeong;Son, Hwan Hee
    • Korean Journal of Childcare and Education
    • /
    • v.17 no.4
    • /
    • pp.93-109
    • /
    • 2021
  • Objective: The purpose of this study is to examine the mediating effect of innovative culture in early childhood education institutions on the relationship between teachers' civic consciousness and actions for building a community in order to obtain methodological information for implementation at a time when the need to build an education community has been raised. Methods: The data were collected through 275 early childhood teachers working in kindergartens and daycare centers Then, descriptive statistics, correlation analysis, and regression were conducted. Results: All three variables civic consciousness, innovative culture, and actions for building a community showed a significant positive correlation. As a result of analyzing the mediating effect of innovation culture, it was found that the indirect effect of teachers' civic consciousness on the actions for building a community through the innovative culture was found to be statistically significant. Conclusion/Implications: This study was found that it is important to strengthen the teacher's civic consciousness and to create an innovative culture of early childhood education institutions in order to promote actions for building an educational community of teachers. This study is meaningful in that it provided implications for the direction of teacher education and formation of an innovative culture in early childhood education institutions for the purpose building an educational community.

Effect of the a floor plan of lobby floor for the Stack Effect in a High-rise Building (고층건물에서 로비층의 평면형태가 연돌효과에 미치는 영향)

  • Lee, June-Ho;Lim, Hyun-Woo;Seo, Jung-Min;Lee, Joong-Hoon;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.293-299
    • /
    • 2009
  • Many kinds of problems by stack effect occur in the high-rise buildings that have the simple plan on the first floor designed only by an external wall and an E/V shaft wall. Therefore, some buildings in the foreign countries has made the additional inside walls between lobby and E/V hall as a countermeasure on stack effect. An additional wall in the lobby is very useful countermeasure on stack problems because lobby is a main airflow path in the building. Decreasing effect on stack problems by an additional wall of lobby is reported in this study. An ordinary office building that has a simple lobby plan is simulated and measured in this study. The results show that characteristics on stack effect are changed by methods of applying additional walls and that alternations of countermeasures which building conditions like the kinds of problems and the problem's velocity etc. are considered are very important.

  • PDF

Self-control of high rise building L-shape in plan considering soil structure interaction

  • Farghaly, A.A.
    • Coupled systems mechanics
    • /
    • v.6 no.3
    • /
    • pp.229-249
    • /
    • 2017
  • A new technique to mitigate irregular buildings with soil structure interaction (SSI) effect subjected to critical seismic waves is presented. The L-shape in plan irregular building for various reasons was selected, subjected to seismic a load which is a big problem for structural design especially without separation gap. The L-shape in plan building with different dimensions was chosen to study, with different rectangularity ratios and various soil kinds, to show the effect of the irregular building on the seismic response. A 3D building subjected to critical earthquake was analyzed by structural analysis program (SAP2000) fixed and with SSI (three types of soils were analyzed, soft, medium and hard soils) to find their effect on top displacement, base shear, and base torsion. The straining actions were appointed and the treatment of the effect of irregular shape under critical earthquake was made by using tuned mass damper (TMD) with different configurations with SSI and without. The study improve the success of using TMDs to mitigate the effect of critical earthquake on irregular building for both cases of study as fixed base and raft foundation (SSI) with different TMDs parameters and configurations. Torsion occurs when the L-shape in plan building subjected to earthquake which may be caused harmful damage. TMDs parameters which give the most effective efficiency in the earthquake duration must be defined, that will mitigate these effects. The parameters of TMDs were studied with structure for different rectangularity ratios and soil types, with different TMD configurations. Nonlinear time history analysis is carried out by SAP2000 with El Centro earthquake wave. The numerical results of the parametric study help in understanding the seismic behavior of L-shape in plan building with TMDs mitigation system.