• 제목/요약/키워드: Building Condition

검색결과 1,918건 처리시간 0.031초

비노출 방수층에 작용하는 정하중과 동하중 작용 후의 방수층 물성변화에 관한 연구 (A Study on the Change of Physical Capability of Waterproofing Layer after the Application of Static Load and Moving Load to a Non-Exposed Type Waterproofing Layer)

  • 선윤숙;김진성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.141-145
    • /
    • 2007
  • The part in the structure that is most affected by changes of external temperature is the protective concrete layer that protects a waterproofing layer. Also, the waterproofing layer that is situated under or on the back of such a protective concrete layer is affected by temperature and the behavior of the protective concrete layer under the condition of consolidation or close adhesion. In particular, in many cases, the damage is serious mainly around the projection (such as a parapet), crack, and joint (expansion joint). However, there is no proper way of examining again the non-exposed waterproofing layer once it has been constructed. Therefore, there is an assessment only on the physical property of materials and the capability of the layer in construction, and there is no actual assessment in consideration of its environmental condition or the condition of the use of buildings after construction. Therefore, in order to create more pleasant buildings and to enhance the durability of structures, this study conducts research into the change of capability of non-exposed waterproofing material after the application of a static load and moving load on the waterproofing layer situated under or on the back of protective concrete.

  • PDF

재료의 경년상태를 고려한 경수로형 격납건물의 극한내압능력 평가 (Evaluation of Ultimate Pressure Capacity of Light Water Reactor Containment Considering Aging of Materials)

  • 이상근;송영철;한상훈;권용길
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.147-154
    • /
    • 2001
  • The prestressed concrete containment is one of the most important structures in nuclear power plants, which is required to prevent release of radioactive or hazardous effluents to the environment even in the case of a severe accident. Numerical analyses are carried out by using the ABAQUS finite element program to assess the ultimate pressure capacity of the Y prestressed concrete containment with light water reactor at design criteria condition and aging condition considering varied properties of time-dependant materials respectively. From the results, it is verified that the structural capacity of the Y prestressed concrete containment building under the present, aging condition is still robust. In addition, the parameter studies for the reduction of the ultimate pressure capacity of containment building according to the degradation levels of the main structural materials are carried out. The results show that when the degradations of each materials are considered as individual and combined forms, the influence is large in the order of tendon, rebar and concrete degradation, and tendon-rebar, tendon-concrete and rebar-concrete degradation respectively.

  • PDF

돌기 시스템을 이용한 입체보강형시트의 옥상노출복합방수공법 적용에 관한 재료 및 공법적 연구 (Study on the Application of Site for Exposure Type of Complex Waterproofing Method with Liquefied Waterproof using of Vertical Type Reinforcing Sheet Material Reinforced Sheet Rising System in the Roof Tops)

  • 오상근;손문세;김진성;여인수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.17-20
    • /
    • 2006
  • It often happen water leakage that roof membrane have a poor condition such as direct exposed to rain, ultraviolet lays, temperature change compare with other part of waterproofing. There are difficult to maintain the quality of waterproofing and durability due to use only few waterproofing materials in practical in spite of development and use the various waterproofing material as solution of these poor condition. Therefore, in this thesis, I would like to know the property to apply field and suggest other method to develop for this waterproofing method to adopt various field condition for roof tops, as searching exposed and complex waterproofing technology for roof tops which is reinforced sheet using rising system have a regular pitch, depth, space.

  • PDF

조강형 결합재를 사용한 콘크리트의 양생온도에 따른 경화특성 실험적 평가 (An experimental evaluation of hardened property of concrete using early-strength-binder with curing temperature)

  • 김광기;김영선;이주호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.88-89
    • /
    • 2015
  • In cold weather, the speed of concrete strength development is slow. As a result, construction speed becomes slow and it is problem for all construction site to solve this. So in this study, to shorten removing frame time after placing concrete, mix proportion using early-strength-binder(ESB) and curing method such as using heat line in concrete was considered. At first, concrete mix proportion was examined at -5℃ temperature between ordinary portland cement(OPC) and ESB. And second step, concrete, using mix proportion with OPC, was examined according to curing method(: 1) heat line used and 2) no heat line) and kinds of form (: 1) Deck slab, 2) Half PC slab and 3) SOG slab). All cases are same condition: slab thickness is 1,500mm, double-bubble sheet is used as a curing sheet after placing concrete. After the test, OPC is enough to get strength compared to ESB in special condition and 48~60 hours is needed according to form condition.

  • PDF

저속습식마쇄기를 이용한 고품질 순환잔골재 제조에 관한 기초적 연구 (A Fundamental Study on Manufacturing Condition the High Quality Recycled Fine Aggregate by Low Speed Wet Rotary Mill)

  • 김하석;이경현;라정민;박효진;임대빈;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.65-68
    • /
    • 2009
  • Recycled aggregate by the recycling construction waste has a lot of advantage such as the developing the alternative resource and protecting of environment. However, recycled aggregate is used as the low quality grade, because the technic to remove old mortar from aggregate is low level. To use the recycled aggregate as high quality grade, it is important to develop the technic to produce the high quality recycled aggregate. To manufacture the high quality recycled aggregate, old mortar attached on the aggregates should remove efficiently. Therefore, in this study, we suggested the optimum condition to remove old mortar effectively using sulfuric acid and low speed wet rotary mill for high quality recycled fine aggregate. The results shows that the recycled aggregate satisfy on the standards of KS F 2573 in density, absorption and solid volume when, adequate condition of sulfuric mole ratio and aggregate ratio are make.

  • PDF

돌기 시스템을 이용한 입체보강형시트의 옥상노출복합방수공법 적용에 관한 재료 및 공법적 연구 (Study on the Application of Site for Exposure Type of Complex Waterproofing Method with Liquefied Waterproof using of Vertical Type Reinforcing Sheet Material Reinforced Sheet Rising System in the Roof Tops)

  • 오상근;손문세;김진성;여인수
    • 한국건축시공학회지
    • /
    • 제6권4호
    • /
    • pp.69-75
    • /
    • 2006
  • It often happen water leakage that roof membrane have a poor condition such as direct exposed to rain, ultraviolet lays, temperature change compare with other part of waterproofing. There are difficult to maintain the quality of waterproofing and durability due to use only few waterproofing materials in practical in spite of development and use the various waterproofing material as solution of these poor condition. Therefore, in this thesis, I would like to know the property to apply field and suggest other method to develop for this waterproofing method to adopt various field condition for roof tops, as searching exposed and complex waterproofing technology for roof tops which is reinforced sheet using rising system have a regular pitch, depth, space.

열원장비의 적정용량산정을 위한 장비가동현황 및 할증률 분석 - 공공업무시설 - (The analysis on the operation condition and premium proportion for estimating the appropriate capacity of Cooling Equipment - Public office-)

  • 신무경;박성훈;박은하;장종운;이지원;김세환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.506-511
    • /
    • 2006
  • To today with the acceleration due to the preference actual condition of high-class energy national income level it is together improving. It follows hereupon and it is convenient and the neat heat source is increasing a tendency where it is. It investigates the government offices building in commerce portion from the research which it sees and from the draft it analyzes a coat dosage. And comparison it analyzes the movable present condition of thread use dosage and the freezer. It presents the improvement direction against enemy conditions heat source equipment selecting. Also, currently it produces the dosage of heat source equipment and application it tries. The result, the various safety rate and the premium rate which it uses universally are considered above thread using. The reappraisal for enemy conditions heat source equipment selecting which it follows hereupon is necessary.

  • PDF

Assessment of structural behavior of reinforced concrete slab ceiling under full load test in a residential complex project

  • Jaffar A. Kadim;Oday A. Abdulrazzaq;Abdulamir A. Karim;Aqeel H. Chkheiwer
    • Structural Engineering and Mechanics
    • /
    • 제89권6호
    • /
    • pp.627-634
    • /
    • 2024
  • This research deals with the process of conducting a reinforced concrete slab loading test of a Residential Complex Project at the Shatt Al Arab District which is located in southern Iraq. The purpose of the test which represents a destructive test is to evaluate the structural behavior of the slab condition state during and after the examination of the test process in order to ascertain the ability of the slab ceiling to withstand the loads generated during the use of the building. The test was carried out accordant to ACI 437.2-13 code. The reason for this test is the postponed 8 years of building project construction. Concrete blocks were used to simulate and conduct a loading test of 30-tons for 3 days. The central point has been installed to measure the slab deflection that occurred during the test. The results showed that both the total deflection and residual deflections were lesser than the permissible values according to the ACI 437.2-13, the RC slab behavior was mainly linear structural behave, and that the purpose of the examination was achieved. Finally, a new method was introduced to the assessment of the slab condition at the support which is found in good condition.

벽식구조 아파트의 고유진동수 측정에 관한 연구 (Measurement of First Natural Frequency in Apartments with Shear Wall)

  • 김하근;김흥식;천영수;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1065-1069
    • /
    • 2001
  • This study aims to suggest the basic data for structural safety assessment and design considering building dynamic characteristics. For this purpose, ambient vibration measurement was practiced after studying international standards dealing with vibration measurements such as ISO, DIN and so on. Various types of situation and condition which help search the building natural frequencies through the field measurements were proposed.

  • PDF

내화강재 적용 단순 보부재의 고온 거동 비교 연구 (Comparative Study of Beams made up of Fire Resistant Steels)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2017
  • Fire is very serious condition in steel based structures. Therefore, to enhance the structural stability of columns and beams in high temperatures, fire resistant steels and TMC fire resistant steels are developed from steel manufacturing companies. In this study to evaluate the structural stability and compare the resistant performance, a fire engineering design method was applied and fire resistant steels showed the better performance than other two materials.

  • PDF