• Title/Summary/Keyword: Buffered Reference

Search Result 11, Processing Time 0.023 seconds

Design of an 1.8V 6-bit 2GSPS CMOS ADC with an One-Zero Detecting Encoder and Buffered Reference (One-Zero 감지기와 버퍼드 기준 저항열을 가진 1.8V 6-bit 2GSPS CMOS ADC 설계)

  • Park Yu Jin;Hwang Sang Hoon;Song Min Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.6 s.336
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, CMOS A/D converter with 6bit 2GSPS Nyquist input at 1.8V is designed. In order to obtain the resolution of 6bit and the character of high-speed operation, we present an Interpolation type architecture. In order to overcome the problems of high speed operation, a novel One-zero Detecting Encoder, a circuit to reduce the Reference Fluctuation, an Averaging Resistor and a Track & Hold, a novel Buffered Reference for the improved SNR are proposed. The proposed ADC is based on 0.18um 1-poly 3-metal N-well CMOS technology, and it consumes 145mW at 1.8V power supply and occupies chip area of 977um $\times$ 1040um. Experimental result show that SNDR is 36.25 dB when sampling frequency is 2GHz and INL/DNL is $\pm$0.5LSB at static performance.

Preparation of Ferroelectric $BaTiO_3$ Thin Films on MgO-Buffered Si Substrates (MgO 완충층을 이용한 Si 기판상 강유전체 $BaTiO_3$ 박막의 제조)

  • 김상섭
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.4
    • /
    • pp.373-379
    • /
    • 1997
  • A study on the deposition and characterization of BaTiO3 thin films on MgO-buffered Si(100) substrates by sputtering was conducted. The MgO buffer layers were investigated as a function of deposition temperature. At lower substrate temperature, the MgO layers were not fully crystalline, but a crystallized MgO layer with (001) preferred orientation was obtained at the substrate temperature of $700^{\circ}C$. Partially (00ι) or (h00) textured BaTiO3 films were obtained on Si(100) with the MgO buffer layer grown at 700ι. While, randomly oriented BaTiO3 films with large-scale cracks on the surface were made without the MgO layer. The crystallographic orientation, morphology and electrical properties between the BaTiO3 films on Si with and without the MgO layer were compared using the BaTiO3 film on MgO(100) single crystal substrate as a reference system. Also the favorable role of the MgO layer as a buffer for growing of oriented BaTiO3 films on Si substrates was confirmed.

  • PDF

pH Measurements with a Microcantilever Array-Based Biosensor System

  • Hur, Shin;Jung, Young-Do
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.186-191
    • /
    • 2012
  • In this paper, we present a pH measurement method that uses a microcantilever-array-based biosensor system. It is composed of microcantilever array, liquid cell, micro syringe pump, laser diode array, position sensitive detector, data acquisition device, and data processing software. Four microcantilevers are functionalized with pH-sensitive MHA(mercaptohexadecanoic acid) as a probe, while three microcantilevers are functionalized with HDT(hexadecane thiol) as reference. We prepare PBS(phosphate buffered saline) solutions of different pH and inject them into the liquid cell with a predefined volumetric speed at regular time intervals. The functionalized mircocantilevers in the liquid cell deflect as a self-assembled monolayer on the microcantilever binds with probe molecules in the solution. The difference in deflection between the MHA-covered probe microcantilever and the HDT-covered reference microcantilever was used to compensate for thermal drift. The deflection difference clearly increases with increasing pH in the solution. It was shown that when the pH values of the PBS solutions are high, there were large variations in the deflection of microcantilevers, whereas there were small variations for low pH value. The experimental results show that the microcantilever array functionalized with MHA and HDT can detect pH value with good repeatability.

Disposable Solid-State pH Sensor Using Nanoporous Platinum and Copolyelectrolytic Junction

  • Noh, Jong-Min;Park, Se-Jin;Kim, Hee-Chan;Chung, Taek-Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3128-3132
    • /
    • 2010
  • A disposable solid-state pH sensor was realized by utilizing two nanoporous Pt (npPt) electrodes and a copolyelectrolytic junction. One nanoporous Pt electrode was to measure the pH as an indicating electrode (pH-IE) and the other assembled with copolyelectrolytic junction was to maintain constant open circuit potential ($E_{oc}$) as a solid-state reference electrode (SSRE). The copolyelectrolytic junction was composed of cationic and anionic polymers immobilized by photo-polymerization of N,N'-methylenebisacrylamide, making buffered electrolytic environment on the SSRE. It was expected to make. The nanoporous Pt surrounded by a constant pH excellently worked as a solid state reference electrode so as to stabilize the system within 30 s and retain the electrochemical environment regardless of unknown sample solutions. Combination between the SSRE and the pH-IE commonly based on nanoporous Pt yielded a complete solid-state pH sensor that requires no internal filling solution. The solid state pH sensing chip is simple and easy to fabricate so that it could be practically used for disposable purposes. Moreover, the solid-state pH sensor successfully functions in calibration-free mode in a variety of buffers and surfactant samples.

Enhanced stability of NADH/dehydrogenase mixture system by water-soluble phospholipid polymers

  • Fukazawa, Kyoko;Ishihara, Kazuhiko
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.1
    • /
    • pp.37-46
    • /
    • 2016
  • To maintain activity in a coenzyme/enzyme mixture system, such as ${\beta}$-nicotinamide adenine dinucleotide (NADH)/dehydrogenase, the water-soluble 2-methacryloyloxyethyl phosphorylcholine (MPC) polymers as an additive were synthesized and investigated for their stabilizing function. The inhibitor for the NADH/dehydrogenase reaction was spontaneously formed when the NADH was stored in the dehydrogenase solution. Therefore, we hypothesized that if the additive polymer could interact with an inhibitor without any adverse effect on the dehydrogenase, the activity in the NADH/dehydrogenase mixture could be maintained. We selected lactose dehydrogenase (LDH) as the enzyme, and the NADH was dissolved and incubated at $37^{\circ}C$ in the LDH solution containing the polymers. The phospholipid polymers used in this study were poly(MPC) (PMPC), poly(MPC-co-3-trimethylammonium-2-hydroxypropyl methacrylate chloride) (PMQ) and poly[MPC-co-potassium 3-methacryloyloxypropyl sulfonate ($MSO_3$)] ($PMMSO_3$). The poly($MSO_3$) was used as a reference. For the PMQ and $PMSO_3$ aqueous solutions, the activity of the NADH/LDH mixture system decreased with incubation time as the same level or lower than that in the Tris buffered solution in the absence of the polymers. However, for the poly($MPC-co-MSO_3$) ($PMMSO_3$) aqueous solution, the activity of the NADH/LDH mixed system was six times higher than that in the buffered solution even after a 3-days incubation. The LDH activity was 1.5-1.8 times higher in the presence of the $PMMSO_3$ compared with that in the $PMSO_3$ solution. The mixture of two polymers, poly(MPC) and poly($MSO_3$), did not produce any stabilization. Thus, both the MPC and $MSO_3$ units in the polymer chain had important and cooperative effects for stabilizing the NADH/LDH mixture.

Preparation of a Liquid Membrance Type Ion-Selective Electrode and Its Application to the Potentiometric Titration (액체막형 구리이온 선택성 전극의 제작과 전위차적정에의 응용)

  • Heung Lark Lee;Seung Tae Yang
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.137-143
    • /
    • 1985
  • Construction of a liquid membrane type of cupric ion selective electrode and its application to the potentiometric titration have been studied. A liquid ion-exchange membrance was prepared by extracting Cu(II) in aqueous solution into 1-(2-pyridylazo)-2-naphthol/nitrobenzene. A Ag/AgCl internal reference electrode was dipped into the aqueous reference solution of $1.00 {\times} 10^{-3}M\;Cu(NO_3)_2$ buffered with HAc-NaAc buffer solution, which was in contact with the nitrobenzene extract. The electrode showed the nernstian response to Cu(II) in the concentration range from $1.00{\times} 10^{-6}$ to $1.00{\times} 10^{-3}$M. The most suitable ion-exchanger concentration in the liquid membrane was $1.00{\times} 10^{-4}$M. The selectivity coefficients of the electrode for the various metal cations were investigated. The electrode was applied to the potentiometric titration of Cu(II) with EDTA.

  • PDF

Detection of Protein Molecules by Electrical Current Response Using Two-Electrode Method

  • Lyu, Hong-Kun;Woo, Sung-Ho;Han, Yoon-Soo;Lee, Hee-Ho;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.90-95
    • /
    • 2011
  • In order to protect human lives from disease, various biosensors having the potential to analyze a variety of biomolecules have been utilized. Biosensors constitute one of the most promising ways to monitor and detect various biomolecules corresponding to diseases. In this study, we demonstrate that the reaction of streptavidin molecules with biotin on a gold electrode can be detected using the twoelectrode method with a gold electrode and a platinum reference electrode. We also show the characteristics of the electrical current response. While detecting 2-${\mu}M$ streptavidin molecules dissolved in phosphate buffered saline(PBS) solution, we found that an analytical biosensor can operate on the principle of detecting an antigen-antibody reaction event of protein molecules using the two-electrode method. We think that the "potential step" method might be useful to detect the occurrence of any antigen-antibody reactions and can be combined with other devices or ICs such as BJTs, MOSFETs, and OP-amps for the detection of biomolecules of diseases.

Detection of deoxynivalenol using a MOSFET-based biosensor (MOSFET형 바이오 센서를 이용한 디옥시 니발레놀의 검출)

  • Lim, Byoung-Hyun;Kwon, In-Su;Lee, Hee-Ho;Choi, Young-Sam;Shin, Jang-Kyoo;Choi, Sung-Wook;Chun, Hyang-Sook
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • We have detected deoxynivalenol(DON) using a metal-oxide-semiconductor field-effect-transistor(MOSFET)-based biosensor. The MOSFET-based biosensor is fabricated by a standard complementary metal-oxide-semiconductor(CMOS) process, and the biosensor's electrical characteristics were investigated. The output of the sensor was stabilized by employing a reference electrode that applies a fixed bias to the gate. Au which has a chemical affinity for thiol was used as the gate metal to immobilize a self-assembled monolayer(SAM) made of 16-mercaptohexadecanoic acid(MHDA). The SAM was used to immobilize anti-deoxynivalenol antibody. The carboxyl group of the SAM was bound to the anti- deoxynivalenol antibody. Anti-deoxynivalenol antibody and deoxynivalenol were bound by an antigen-antibody reaction. In this study, it is confirmed that the MOSFET-based biosensor can detect deoxynivalenol at concentrations as low as 0.1 ${\mu}g$/ml. The measurements were performed in phosphate buffered saline(PBS; pH 7.4) solution. To verify the interaction among the SAM, antibody, and antigen, surface plasmon resonance(SPR) measurements were performed.

Bacterial Leaf Spot and Dry Rot of Lettuce Caused by Xanthomonas campestris pv. vitians (Xanthomonas campestris pv. vitians에 의한 상추 세균성점무늬병)

  • Lee, Seung-Don;Lee, Jung-Hee;Kim, Yong-Ki;Heu, Sung-Gi;Ra, Dong-Soo
    • Research in Plant Disease
    • /
    • v.13 no.1
    • /
    • pp.66-70
    • /
    • 2007
  • During 1997 and 1998, a new disease of lettuce (Lactuca sativa) was observed on greenhouse-grown plants in Kwangju and Kwangmyung. Lesions on leaves were irregular, small, pale green to black, water-soaked, and 2 to 5 mm in diameter, Coalescing lesions sometimes caused defoliation of older leaves. Isolations made from diseased leaves on yeast extract dextrose calcium carbonate agar yielded nearly pure cultures of a yellow pigmented bacterium typical of a xanthomonad. Two bacterial strains (SL0246 and SL1352) were purified and used for further tests. Pathogenicity of strains was confirmed on 5-week-old lettuce plants injected with bacterial suspensions containing $10^8$ cfu/ml of phosphate buffered saline. The representative Xanthomonas strains isolated from lettuce were compared with a reference strain X. campestris pv, vitians for fatty acid profiles and metabolic fingerprints using GN2 microplate, showing that all outcomes were indistinguishable between the representative and reference strains. This is the first report of bacterial leaf spot and dry rot of lettuce in Korea.

Influence of Forest Management on the Facility of Cleansing Water Quality in Abies holophylla and Pinus koraiensis Watershed(III) -With a Special Reference to pH and Electrical Conductivity of Rainfall, Throughfall and Stemflow- (전나무림(林), 잣나무림(林) 유역(流域)에서 산림(山林)의 수질정화기능(水質淨化機能)에 미치는 산림시업(山林施業) 영향(影響)(III) -임외우(林外雨), 수관통과우(樹冠通過雨), 수간류(樹幹流)의 pH와 전기전도도(電氣傳導度)를 중심(中心)으로-)

  • Jeong, Yongho;Park, Jae Hyeon;Youn, Ho Joong;Kim, Kyong Ha
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.223-231
    • /
    • 2000
  • This study aims to clarify the effect of forest management practices(thinning and pruning) on water quality to get the fundamental information on the facility of cleansing water quality after forest operation. Rainfall, throughfall and stemflow were sampled at the study sites which consist of Abies holophylla and Pinus koraiensis in Kwangnung Experimental Forest for 6 months from May 4, to November 1, 1999. Average tree height in the management sites increased by 0.5m more than that in the non-management sites in Abies holophylla and Pinus koraiensis, respectively. Increment of average D.B.H. at the management sites grew 3.5cm and 2.6cm more in Abies holophylla and Pinus koraiensis compared with that at non-management sites. Average pH of the total amount for the event in throughfall and stemflow was higher than that of throughfall and stemflow of the beginning of the event at the management and non-management sites. Average electrical conductivity of throughfall and stemflow at the beginning of the event was higher than that of the total amount for the event at management and non-management sites. Water qualities of throughfall and stemflow were buffered more by the management practice in both. The forest management may affect purification of water quality of throughfall and stemflow in Abies holophylla and Pinus koraiensis.

  • PDF