• Title/Summary/Keyword: Buffer material

Search Result 537, Processing Time 0.037 seconds

Use of Real-Time PCR and Internal Standard Addition Method for Identifying Mixed Ratio of Chicken Meat in Sausages (Real-Time PCR과 Internal Standard Addition법을 이용한 돼지고기 소시지에 혼합된 닭고기의 정량)

  • Lee, Namrye;Joo, Jae-Young;Yeo, Yong-Heon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1097-1105
    • /
    • 2017
  • This study examined how much chicken meat was in sausage made with pork. Both real-time polymerase chain reaction (PCR) and internal standard addition were used. Fifty ng of chicken DNA was added to the sausages as an internal standard. The addition of standard DNA increased the amplification efficiency of PCR and confirmed the possibility of quantitative analysis. A QIAamp DNA Micro Kit was used to improve the DNA recovery and amplification efficiency. The density of template DNA and primer were suitable for $3.0{\sim}5.0{\mu}L$ and $0.5{\mu}L$, respectively. Each DNA of pig and chicken was diluted in 10-fold from steps 50 ng to 0.05 ng. The detection limit of both pig and chicken meat was more than 0.05 ng and the correlation coefficient of the standard curve was at least 0.98. The result of the quantitative analysis after heat treatment of 3 samples of pigs and chickens mixed at 70:30 showed a 5.7% difference (64.3:35.7) between the expected value and measured value. The quantitative value was changed by affecting the DNA according to the heat treatment ($70^{\circ}C$, 10 min). An analysis of the pork and chicken content in sausages showed that it was difficult to detect chicken meat and the quantitative value of DNA according to the Ct value was very low. On the other hand, when adding standard material (50 ng of chicken DNA) to the sausages, the Ct value decreased gradually with increasing chicken mixing ratio. Thus, the mixing ratio of chicken in sausages could be estimated.

$^{17}O$ NMR Study On Water Excharge Rate of Paramagnetic Contrast Agents ($^{17}O$ NMR 기법을 이용한 상자성 자기공명조영제의 물분자 교환에 관한 연구)

  • Yongmin Chang;Sung Wook Hong;Moon Jung Hwang;Il Soo Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2001
  • Purpose : The water exchange rate between bulk water and bound water is an important parameter in deciding the efficiency of paramagnetic contrast agents. In this study, we evaluated the water exchange rates of various Gd-chelates using oxygen-17 NMR technique. Material and Methods : The samples (Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, Gd-EOB-DTPA) were prepared by mixing 5% $^{17}O-enriched$ water (Isotech, USA). The pH of the samples was adjusted to physiological value [pH=7.0] by buffer solution. The variable temperature $^{17}O-NMR$ measurements were performed using Bruker-600 (14.1 T, 81.3 MHz) spectrometer. Bruker VT-1000 temperature control units were used to stabilize the temperature. The $^{17}O$ spin-spin relaxation times (T2) were measured using Carr-Purcell-Meiboom-Gill (CPMG)I pulse sequence with 24 echo trains. The variable temperature T2 relaxation data were then fitted into Solomon-Bloembergen equations using least square fit algorithm to estimate the water exchange times. Results : From the measured $^{17}O-NMR$ relaxation rates, the determined water exchange rates at 300K are $0.42{\;}{\mu}s$ for Gd-DTPA, $1.99{\;}{\mu}s$ for Gd-DTPA-BMA, $0.27{\;}{\mu}s$ for Gd-DOTA, and $0.11{\;}{\mu}s$ for Gd-EOB-DTPA. The Gd-DTPA-BMA showed slowest exchange whereas Gd-EOB-DTPA had fastest water exchange rate. In addition, it was found that the water exchange rates (${\tau}_m$) of all samples had exponential temperature dependence with different decay constant. Conclusion : $^{17}O-NMR$ relaxation rate measurements, when combined with variable temperature technique, provide a solid tool for studying water exchange rate, which is very important in investigating the detailed mechanism of relaxation enhancement effect of the paramagnetic contrast agents.

  • PDF

Survival and Cross-contamination of Escherichia coli O157:H7 on Various Agricultural Product-Contact Surfaces (농산물 접촉 표면 재질에 따른 Escherichia coli O157:H7의 생존 및 상추로의 교차오염도 조사)

  • Kim, Se-Ri;Choi, Song-Yi;Seo, Min-Kyoung;Kim, Won-Il;Chung, Duck-Hwa;Ryu, Kyoung Yul;Yun, Jong-Chul;Kim, Byung-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.272-278
    • /
    • 2013
  • To evaluate the effect of surface contaminated with Escherichia coli O157:H7 (E. coli O157:H7) on the microbiological safety of lettuce, this study was conducted to investigate the attachment, biofilm producing, survival, and cross-contamination of E. coli O157:H7 on stainless steel and polyvinyl chloride (PVC). The attachment rate of E. coli O157:H7 on PVC was 10 times higher than that on stainless steel after exposure 1 h in cell suspension. However, there was not a difference between two types of surface after exposure for 6 h and 24h. The biofilm producing of E. coli O157:H7 was TSB > 10% lettuce extracts > 1% lettuce extracts > phosphate buffer. When two kinds of materials were stored at various conditions ($20^{\circ}C$ and $30^{\circ}C$, relative humidity (RH) 43%, 69%, and 100%), the numbers of E. coli O157:H7 at $30^{\circ}C$, RH 43% or RH 69% were reduced by 5.0 log CFU/coupon within 12 h regardless of material type. Conversely, the survival of E. coli O157:H7 at RH 100% was lasted more than 5 days. In addition, the reduction rate of E. coli O157:H7 was decreased in the presence of organic matter. The transfer efficiency of E. coli O157:H7 from the contaminated surface to lettuce was dependent upon the water amount of the surface of lettuce. Especially, the transfer rate of E. coli O157:H7 was increased by 10 times in the presence of water on the lettuce surface. From this study, the retention of E. coli O157:H7 on produce contact surfaces increase the risk cross-contamination of this pathogen to produce. Thus, it is important that the surface in post harvest facility is properly washed and sanitized after working for prevention of cross-contamination from surface.

Comparative Analysis of arterial Gases and Acid-base status in Patients with Congenital and Acquired Heart Disease at Preoperative Period, During Extracorporeal Circulation. and Postoperative Period (선천성 및 후천성 심질환 환자에서 체외순환 전, 중, 후의 동맥혈 가스의 비교 분석)

  • 이동석;이봉근;김송명
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.831-842
    • /
    • 2001
  • Background: Patients with cardiac diseases who have structural defects in their heart bring about metabolic insult such as preoperative acid-base imbalance. Cardiac operation requires many nonphysiologic procedures such as extracorporeal circulation, hypothermia, and hemodilution. We studied the acid-base status of surgical heart diseases pre-operatively, during extracorporeal circulation, and post-operatively and researched the treatment indications of acid-base disturbances. Material and Method: From January 1997 to May 1999, fifty two cases of open heart surgery were carried out under extracorporeal circulation, which divided into a set of pediatric and adult groups, congenital and acquired groups, non-cyanotic and cyanotic groups, The $\alpha$ -stat arterial blood gas analysis was done in each group during the preoperative period, during the operation with extracorporeal circulation, and during the postoperative period. Result: Before surgery, all patients present metabolic acidosis, PaO2 was low in adult group and acquired group and compensatory respiratory alkalosis was noted in cyanotic group. During extracorporeal circulation, adult group revealed alkalosis and normal in acquired group. Pediatric group presents low Pa$CO_2$, metabolic acidosis and respiratory alkalosis. Congenital group and non-cyanotic group showed non-compensatory alkalosis trend and non-compensatory respiratory acidosis were observed in cyanotic group during extracorporeal circulation. Postoperative acid-base status of adult group was recovered to normal and the standard bicarbonate was increased in the acquired group. All of the pediatric, congenital non-cyanotic, and cyanotic groups revealed the lack of buffer base.

  • PDF

Development of Lateral Flow Immunofluorescence Assay Applicable to Lung Cancer (폐암 진단에 적용 가능한 측면 유동 면역 형광 분석법 개발)

  • Supianto, Mulya;Lim, Jungmin;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.173-178
    • /
    • 2022
  • A lateral flow immunoassay (LFIA) method using carbon nanodot@silica as a signaling material was developed for analyzing the concentration of retinol-binding protein 4 (RBP4), one of the lung cancer biomarkers. Instead of antibodies mainly used as bioreceptors in nitrocellulose membranes in LFIA for protein detection, aptamers that are more economical, easy to store for a long time, and have strong affinities toward specific target proteins were used. A 5' terminal of biotin-modified aptamer specific to RBP4 was first reacted with neutravidin followed by spraying the mixture on the membrane in order to immobilize the aptamer in a porous membrane by the strong binding affinity between biotin and neutravidin. Carbon nanodot@silica nanoparticles with blue fluorescent signal covalently conjugated to the RBP4 antibody, and RBP4 were injected in a lateral flow manner on to the surface bound aptamer to form a sandwich complex. Surfactant concentrations, ionic strength, and additional blocking reagents were added to the running buffer solution to optimize the fluorescent signal off from the sandwich complex which was correlated to the concentration of RBP4. A 10 mM Tris (pH 7.4) running buffer containing 150 mM NaCl and 0.05% Tween-20 with 0.6 M ethanolamine as a blocking agent showed the optimum assay condition for carbon nanodot@silica-based LFIA. The results indicate that an aptamer, more economical and easier to store for a long time can be used as an alternative immobilizing probe for antibody in a LFIA device which can be used as a point-of-care diagnosis kit for lung cancer diseases.

Alternative Concept to Enhance the Disposal Efficiency for CANDU Spent Fuel Disposal System (CANDU 사용후핵연료 처분시스템 효율향상 개념 도출)

  • Lee, Jong-Youl;Cho, Dong-Geun;Kook, Dong-Hak;Lee, Min-Soo;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.169-179
    • /
    • 2011
  • There are two types of nuclear reactors in Korea and they are PWR type and CANDU type. The safe management of the spent fuels from these reactors is very important factor to maintain the sustainable energy supply with nuclear power plant. In Korea, a reference disposal system for the spent fuels has been developed through a study on the direct disposal of the PWR and CANDU spent fuel. Recently, the research on the demonstration and the efficiency analyses of the disposal system has been performed to make the disposal system safer and more economic. PWR spent fuels which include a lot of reusable material can be considered being recycled and a study on the disposal of HLW from this recycling process is being performed. CANDU spent fuels are considered being disposed of directly in deep geological formation, since they have little reusable material. In this study, based on the Korean Reference spent fuel disposal System (KRS) which was to dispose of both PWR type and CANDU type, the more effective CANDU spent fuel disposal systems were developed. To do this, the disposal canister for CANDU spent fuels was modified to hold the storage basket for 60 bundles which is used in nuclear power plant. With these modified disposal canister concepts, the disposal concepts to meet the thermal requirement that the temperature of the buffer materials should not be over $100^{\circ}C$ were developed. These disposal concepts were reviewed and analyzed in terms of disposal effective factors which were thermal effectiveness, U-density, disposal area, excavation volume, material volume etc. and the most effective concept was proposed. The results of this study will be used in the development of various wastes disposal system together with the HLW wastes from the PWR spent fuel recycling process.

Electrochemical Performance of CB/SiOx/C Anode Materials by SiOx Contents for Lithium Ion Battery (SiOx 함량에 따른 CB/SiOx/C 음극재의 전기화학적 특성)

  • Kim, Kyung Soo;Kang, Seok Chang;Lee, Jong Dae;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.117-123
    • /
    • 2021
  • In this study, the composite was prepared by mixing SiOx, soft carbon, and carbon black and the electrochemical properties of lithium ion battery were investigated. The content of SiOx added to improve the capacity of the soft carbon anode material was varied to 0, 6, 8, 10, 20 wt%, and carbon black was added as a structural stabilizer for reducing the volume expansion of SiOx. The physical properties of prepared CB/SiOx/C composite were investigated through XRD, SEM, EDS and powder resistance analysis. In addition, the electrochemical properties of prepared composite were observed through the charge/discharge capacity, rate and impedance analysis of the lithium ion battery. The prepared CB/SiOx/C composite had an inner cavity capable of mitigating the volume expansion of SiOx by adding carbon black. The formed internal cavity showed a low initial efficiency when the SiOx content was less than 8 wt%, and low cycle stability when the content of SiOx was less than 20 wt%. The CB/SiOx/C composite containing 10 wt% of SiOx showed an initial discharge capacity of 537 mAh/g, a capacity retention rate of 88%, and a rate of 79 at 2C/0.1C. SiOx was added to improve the capacity of the soft carbon anode material, and carbon black was added as a structural stabilizer to buffer the volume change of SiOx. In order to use the CB/SiOx/C composite as a high-efficiency anode material, the mechanism of the optimal SiOx and the use of carbon black as a structural stabilizer was discussed.

Effect of EC Level of Nutrient Solution on the Yield and Quality of Cut Rose Based on Mixed Coir and Perlite (코이어와 펄라이트 혼합배지를 이용한 절화장미 수경재배 시급액농도가 수량 및 품질에 미치는 영향)

  • Choi, Gyeong-Lee;Cho, Myeong-Whan;Seo, Tae-Cheol;Roh, Mi-Young;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.348-353
    • /
    • 2009
  • Organic materials reveal the remarkable absorption and high buffer capacity for nutrient. Hence, organic materials need some different nutrient management skill from inorganic one. The objective of this study was to evaluate the effect of EC level of nutrient solution on the yield and quality of cut rose grown in the mixed substrate of coir and perlite. 3 EC levels of nutrient solution was treated, which were 0.7, 1.0, 1.3 times of standard solution (Aichiken solution, Japan) for cut rose hydroponics. EC of the standard solution was changed by season following as 1.4 (Apr.~June), 1.0 (July~Aug.), 1.4 (Sep.~Oct.), and $1.6dS{\cdot}m^{-1}$ (Nov.~Mar.) subsequently. The supply of nutrient solution was controlled by the signal of water potential at -5kPa using frequency domain reflectometry (FDR) sensor. As the results, marketable yield was similar for all treatments until 3rd harvest, but was decreased in high EC level from 4th harvest to 7th harvest as final. 0.7 times of standard solution decreased the ratio of unmarketable rose having short stem below 70cm and increased the ratio of high quality rose having long stem above 91cm. The flower weight and stem diameter of cut rose was higher in the low EC treatment than the others.

Effect of Different Exercise Intensity on Blood Melatonin Density in Sleep Disordered Rats (운동 강도가 수면장애 모델 쥐의 혈 중 멜라토닌 농도에 미치는 영향)

  • Kim, Hee-Jung;Kim, Dong-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.45-53
    • /
    • 2014
  • PURPOSE: In this study, we tried to find out what kind of exercise was more effective in sleep disorder by comparing melatonin in blood after applying low intensity with high intensity exercise to sleep disordered rats induced by experiment. METHODS: We used male Sprague-Dawley rats which were 8weeks old and weighted 300g. They were supplied with water and food without any restriction. We kept the room temperature at $25^{\circ}C$ and controld the length of day and night in 12 hours blocks, respectively. We divided the rats 60 into 2 groups. To one group we applied low intensity exercise, and to the other we applied high intensity exercise for 15minutes per day over a period of 4 weeks. We extracted the blood from abdominal aorta before, after exercise, moved into EDTA tube, performed centrifugation. We decanted the serum $200{\mu}l$ from the blood into microcentrifuge tube by samples and moved into polypropylene culture tubes with micro pipette. We split enzyme solution $50{\mu}l$ into the tubes with melatonin direct kits and make them react at $37^{\circ}C$ for 2 hours. We split assay buffer $50{\mu}l$ into each tube and mixed melatonin tracer $50{\mu}l$ and melatonin antiserum $50{\mu}l$, respectively. After we made them react in room temperature, we decanted the superficial layer with a centrifuge and measured the activity for 1 minute by competitive method with ${\gamma}$-counter equipment. We draw a standard curve through logit-log graph with CPM(counts per minute) and counted the melatonin by B/B0. We conducted independent t-test to examine the homogeneous of melatonin value of before low-intensity and high-intensity exercise. We performed paired t-test to compare before and after low-intensity and high-intensity exercise, respectively. We carried out independent t-test to compare melatonin value after low-intensity and high-intensity exercise. Significance level was .05. RESULTS: The results were as follows; firstly melatonin was more increased in the group who was exposed to high intensity exercise when we compared before to after high and low intensity exercise, respectively. Secondly, high intensity exercise was more effective than low intensity exercise when we compared the two. CONCLUSION: In conclusion, secretion of melatonin which is the material of sleep improvement could be promoted by high intensity exercise. Low intensity exercise acted as a stress rather than improving sleep and had a negative effect on the secretion of melatonin because the melatonin was affected by stress.

A study on nonlinear crash analysis of railway tankcar according to the overseas crashworthiness regulations (해외 충돌안전규정에 따른 유류탱크화차의 비선형충돌해석 연구)

  • Son, Seung Wan;Jung, Hyun Seung;Ahn, Seung Ho;Kim, Jin Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.843-850
    • /
    • 2020
  • The purpose of this study is to evaluate the structural risk and weakness of a railway tank car through nonlinear collision analysis according to overseas collision safety standards. The goal is to propose a crash safety design guideline for railway tank cars for transporting dangerous goods in Korea. We analyzed the buffer impact test procedure of railway freight cars prescribed in EN 12663-2 and the tank puncture test criteria prescribed in 49CFR179. A nonlinear finite element model according to each standard was modeled using LS-DYNA, a commercial finite element analysis solver. As a result of the buffing impact test simulation, it was predicted that plastic deformation would not occur at a collision speed of 6 km/h or less. However, plastic deformation was detected at the rear of the center sill and at the tank center supporting the structure at a collision speed of 8 km/h or more. As a result of a head-on test simulation of tank puncture, the outer tank shell was destroyed at the corner of the tank head when 4% of the kinetic energy of the impacter was absorbed. The tank shell was destroyed in the area of contact with the impacter in the test mode analysis of tank shell puncture when the kinetic energy of the moving vehicle was reduced by 30%. Therefore, the simulation results of the puncture test show that fracture at the tank shell and leakage of the internal material is expected. Consequently, protection and structural design reinforcement are required on railway tank cars in Korea.