• 제목/요약/키워드: Buckling Test

검색결과 501건 처리시간 0.027초

Experimental study on dynamic buckling phenomena for supercavitating underwater vehicle

  • Chung, Min-Ho;Lee, Hee-Jun;Kang, Yeon-Cheol;Lim, Woo-Bin;Kim, Jeong-Ho;Cho, Jin-Yeon;Byun, Wan-Il;Kim, Seung-Jo;Park, Sung-Han
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제4권3호
    • /
    • pp.183-198
    • /
    • 2012
  • Dynamic buckling, also known as parametric resonance, is one of the dynamic instability phenomena which may lead to catastrophic failure of structures. It occurs when compressive dynamic loading is applied to the structures. Therefore it is essential to establish a reliable procedure to test and evaluate the dynamic buckling behaviors of structures, especially when the structure is designed to be utilized in compressive dynamic loading environment, such as supercavitating underwater vehicle. In the line of thought, a dynamic buckling test system is designed in this work. Using the test system, dynamic buckling tests including beam, plate, and stiffened plate are carried out, and the dynamic buckling characteristics of considered structures are investigated experimentally as well as theoretically and numerically.

공업용 플라스틱으로 보강된 비좌굴가새의 실험적 구조성능평가 (Experimental Structural Performance Evaluation of Precast-Buckling Restrained Brace Reinforced With Engineering Plastics)

  • 김유성;김기철;강주원;이준호
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.43-52
    • /
    • 2020
  • In this study, the Buckling restrained braces reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. The proposed PC-BRB was fabricated to evaluate the reinforcement effect by carrying out a structural performance test and a full-scale two-layer frame test through cyclic loading test. As a result of PC-BRB's incremental and cyclic loading test, stable hysteresis behavior was achieved within the target displacement, and the compressive strength adjustment coefficient satisfied the recommendation. As a result of the real frame experiment, the strength of the reinforced specimen increased compared to the unreinforced specimen, and the ductility and energy dissipation increased.

복합재 반자율 무인잠수정(SAUV)의 내압선체 설계, 구조해석 및 내압시험 결과에 관한 검토 (A Study on the Results of the Pressure Vessel Design, Structural Analysis, and Pressure Test of the Semi-Autonomous Underwater Vehicle (SAUV))

  • 정태환;이종무;홍석원;김진봉;안진우
    • 한국해양공학회지
    • /
    • 제18권4호
    • /
    • pp.52-58
    • /
    • 2004
  • A Semi-Autonomous Underwater Vehicle (SAUV), capable of simple work on the seabed, is under development in KRISO-KORDI. This SAUV pressure vessel is composed of fiberglass reinforced plastic (FRP), and is also manufactured to carry electronic equipment. The objective of this paper is to describe the safety check for the pressure vessel. This is achieved fly conducting structural analysis and testing in a pressure tank. Strain and stress test results, under unit load, are obtained fly using ANSYS in linear structural analysis. Local buckling analysis are performed with NASTRAN at the middle oj the cylindrical hull. The first test, using linear structural analysis, is unsuccessful, as buckling occurred. During the second test, linear structural analysis, combined with local buckling analysis, is conducted. There is no buckling up to 250 m when both ANSYS and NASTRAN are used.

경수로용 핵연료집합체 지지격자의 좌굴특성에 관한 연구 (A Study on the Buckling Characteristics of Spacer Grids in Pressurized Water Reactor Fuel Assembly)

  • 전상윤;이영신
    • 한국전산구조공학회논문집
    • /
    • 제18권4호통권70호
    • /
    • pp.405-416
    • /
    • 2005
  • 본 연구에서는 경수로용 핵연료집합체의 전체지지격자(Full Size Grid)와 부분지지격자(Small Size Grid)에 대한 정적 좌굴강도 실험과 전체 지지격자와 부분지지격자를 구성하는 지지격자판(Grid Strap)에 대한 정적 좌굴해석을 수행하여 지지격자의 좌굴특성을 분석하였으며, 분석결과를 이용하여 전체지지격자와 부분지지격자에 대한 좌굴하중값의 예측 가능성을 평가하였다. 좌굴강도 실험은 웨스팅하우스형 연료의 $17{\times}17$셀을 갖는 전체지지격자와 $1{\times}1,\;1{\times}2,\;1{\times}3,\;1{\times}4,\;1{\times}5,\;1{\times}17\;,2{\times}1,\;2{\times}2,\;2{\times}3,\;2{\times}9,\;2{\times}17,\;3{\times}17$ 등의 셀을 갖는 부분지지격자에 대하여 수행하였으며, 실험결과를 이용하여 지지격자의 좌굴강도와 지지격자의 행(rows)과 열(columns) 사이의 관계식을 제시하였다. 좌굴강도 해석은 범용 유한요소해석코드인 ANSYS를 이용하여 수행하였으며, 해석결과를 이용하여 지지격자의 좌굴특성을 분석하고 실험결과와 비교평가 하였다.

Cyclic test of buckling restrained braces composed of square steel rods and steel tube

  • Park, Junhee;Lee, Junho;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.423-436
    • /
    • 2012
  • In this study total of six buckling-restrained braces (BRBs) were manufactured using a square steel rod as a load-resisting core member and a hollow steel tube as restrainer to prevent global buckling of the core. The gap between the core and the tube was filled with steel rods as filler material. The performances of the proposed BRB from uniaxial and subassemblage tests were compared with those of the specimens filled with mortar. The test results showed that the performance of the BRB with discontinuous steel rods as filler material was not satisfactory, whereas the BRBs with continuous steel rods as filler material showed good performance when the external tubes were strong enough against buckling. It was observed that the buckling strength of the external tube of the BRBs filled with steel rods needs to be at least twice as high as that of the BRBs filled with mortar to ensure high cumulative plastic deformation of the BRB.

Analysis of the buckling failure of bedding slope based on monitoring data - a model test study

  • Zhang, Qian;Hu, Jie;Gao, Yang;Du, Yanliang;Li, Liping;Liu, Hongliang;Sun, Shangqu
    • Geomechanics and Engineering
    • /
    • 제28권4호
    • /
    • pp.335-346
    • /
    • 2022
  • Buckling failure is a typical slope instability mode that should be paid more attention to. It is difficult to provide systematic guidance for the monitoring and management of such slopes due to unclear mechanism. Here we examine buckling failure as the potential instability mode for a slope above a railway tunnel in southwest China. A comprehensive model test system was developed that can be used to conduct buckling failure experiments. The displacement, stress, and strain of the slope were monitored to document the evolution of buckling failure during the experiment. Monitoring data reveal the deformation and stress characteristics of the slope with different slipping mass thicknesses and under different top loads. The test results show that the slipping mass is the main subject of the top load and is the key object of monitoring. Displacement and stress precede buckling failure, so maybe useful predictors of impending failure. However, the response of the stress variation is earlier than displacement variation during the failure process. It is also necessary to monitor the bedrock near the slip face because its stress evolution plays an important role in the early prediction of instability. The position near the slope foot is most prone to buckling failure, so it should be closely monitored.

종이의 단축압축 표준시험법 개발

  • 김형진;엄기증;이태주;고승태;유영정
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2007년도 추계학술발표논문집
    • /
    • pp.325-330
    • /
    • 2007
  • Uniaxial tensile test are generally much simpler than uniaxial compressive test. Uniaxial compressive test is experimentally more difficult because of the low buckling resistance of a sheet of paper. In order to avoid buckling, many researchers have applied various lateral restraint techniques to investigate paper uniaxial compression behavior. Adding unnecessary force to inhibit compressive deformation of the sheet is unwanted, but sufficient force must be used to inhibit buckling. This study has been carried out to develop new uniaxial compressive standard test method without exerting unnecessary force to paper specimen to prevent buckling.

  • PDF

사각 관 구조물의 충격에 의한 좌굴특성 (Buckling Behavior of a Square Tube Structure by Lateral Impact Load)

  • 윤경호;송기남;강흥석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.812-818
    • /
    • 2001
  • The drop type impact test and finite element analysis are established for examining the buckling behavior of a square tube under the lateral impact load. Based on these results, the effects by the boundary conditions for supporting the structure are reviewed, which are as follows. One is pinned condition by screw; the other is fixed by welding. The critical impact force and acceleration by test are nearly same between two cases. However, the critical impact velocity of the pinned condition is higher than that of the fixed case. Therefore, the dynamic buckling behavior of a pinned structure is better than the fixed condition in view of critical impact velocity. These test and analysis results will be adaptable for predicting the dynamic structural integrity of a tube structure not only the axial impact event but the lateral impact event.

  • PDF

엑츄에이터를 이용한 송전철탑의 1/2 축소부분실험 (Half-Scaled Substructure Test of a Transmission Tower Using Actuators)

  • 문병욱;박지훈;이성경;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.178-188
    • /
    • 2007
  • In this paper, a half-scaled substructure test was performed to evaluate the buckling and structural safety of an existing transmission tower subjected to wind load. A loading scheme was devised to reproduce the dead and wind loads of a prototype transmission tower, which uses a triangular jig that is mounted on the reduced model to which the similarity law of a half length was applied. As a result of the preliminary numerical analysis carried out to evaluate the stability of a specimen for the design load, it was confirmed that the calculated axial forces of tower leg members were distributed to $80{\sim}90%$ of an admissible buckling load. When the substructured transmission tower was loaded by 270% of its maximum admissible buckling load, it was failed due to the local buckling that is occurred in joints with weak constraints for out-of-plane behavior of leg members. By inspection of load-displacement curves, displacements and strains of members, it is considered that this local buckling was due to additional eccentric force by unbalanced deformation because the time that is reached to yielding stress due to the bending moment is different at each point of a same section.

  • PDF

Buckling resistance behavior of WGJ420 fire-resistant weathering steel columns under fire

  • Yiran Wu;Xianglin Yu;Yongjiu Shi;Yonglei Xu;Huiyong Ban
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.269-287
    • /
    • 2023
  • The WGJ420 fire-resistant weathering (FRW) steel is developed and manufactured with standard yield strength of 420 MPa at room temperature, which is expected to significantly enhance the performance of steel structures with excellent fire and corrosion resistances, strong seismic capacity, high strength and ductility, good resilience and robustness. In this paper, the mechanical properties of FRW steel plates and buckling behavior of columns are investigated through tests at elevated temperatures. The stress-strain curves, mechanical properties of FRW steel such as modulus of elasticity, proof strength, tensile strength, as well as corresponding reduction factors are obtained and discussed. The recommended constitutive model based on the Ramberg-Osgood relationship, as well as the relevant formulas for mechanical properties are proposed, which provide fundamental mechanical parameters and references. A total of 12 FRW steel welded I-section columns with different slenderness ratios and buckling load ratios are tested under standard fire to understand the global buckling behavior in-depth. The influences of boundary conditions on the buckling failure modes as well as the critical temperatures are also investigated. In addition, the temperature distributions at different sections/locations of the columns are obtained. It is found that the buckling deformation curve can be divided into four stages: initial expansion stage, stable stage, compression stage and failure stage. The fire test results concluded that the residual buckling capacities of FRW steel columns are substantially higher than the conventional steel columns at elevated temperatures. Furthermore, the numerical results show good agreement with the fire test results in terms of the critical temperature and maximum axial elongation. Finally, the critical temperatures between the numerical results and various code/standard curves (GB 51249, Eurocode 3, AS 4100, BS 5950 and AISC) are compared and verified both in the buckling resistance domain and in the temperature domain. It is demonstrated that the FRW steel columns have sufficient safety redundancy for fire resistance when they are designed according to current codes or standards.