• Title/Summary/Keyword: Buckling Test

Search Result 501, Processing Time 0.022 seconds

A Study on the Structural Behavior and the Strength of Circular Hollow Steel(CHS) Section Columns (원형강관 기둥의 구조적인 거동 및 강도에 관한 연구)

  • Kang, Doo Won;Kwon, Young Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.505-514
    • /
    • 2009
  • This paper describes the structural behavior and the ultimate strengths of circular hollow steel (CHS) sections based on a series of compression tests. The ultimate strengths of CHS section columns are mainly dependent on both diameter-thickness ratio and column slenderness ratio. For the CHS sections with a high diameter-thickness ratio, an elastic or an inelastic local buckling may occur prior to the overall buckling, and it may decrease the column strength. Test sections were fabricated from SM400 steel plate of 2.8 mm and 3.2 mm in thickness and were tested to failure. The diameter-thickness ratios of the test sections ranged from 45 to 170 to investigate the effect of local buckling on the column strength. The compression tests indicated that the CHS sections of lower diameter-thickness ratio than the yield limit in the current design specifications showed an inelastic local buckling and a significant post-buckling strength in the local mode. Their ultimate stresses were larger than the nominal yield stress. It was known that the allowable stresses of the sections predicted by the Korean Highway Bridge Design Specifications (2005) were too conservative in comparison with test results. The Direct Strength Method which was newly developed was calibrated for application to the CHS sections by the experimental and numerical results. The Direct Strength Method proposed can predict properly the ultimate strength of CHS section columns whether a local buckling and an overall buckling occur nearly simultaneously or not.

Half-Scaled Substructure Test for the Performance Evaluation of a Transmission Tower subjected to Wind Load (송전철탑의 내풍안전성 평가를 위한 1/2축소부분구조 실험)

  • Moon, Byoung-Wook;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.641-652
    • /
    • 2007
  • In this paper, a half-scaled substructure test was performed to evaluate the buckling and structural safety of an existing transmission tower subjected to wind load. A loading scheme was devised to reproduce the dead and wind loads of a prototype transmission tower, which uses a triangular jig that is mounted on the reduced model to which the similarity law of a half length was applied. As a result of the preliminary numerical analysis carried out to evaluate the stability of a specimen for the design load, is was confirmed that the calculated axial forces of tower leg members were distributed to $80{\sim}90%$ of an admissible buckling load. When the substructured transmission tower was loaded by 270% of its maximum admissible buckling load, it was failed due to the local buckling that is occurred in joints with weak constraints for out-of-plane behavior of leg members. By inspection of load-displacement curves, displacements and strains of members, it is considered that this local buckling was due to additional eccentric force by unbalanced deformation because the time that is reached to yielding stress due to the bending moment is different at each point of a same section.

Buckling of Filament Wound Thick Composite Cylinders under External Hydrostatic Pressure (외부 수압을 받는 필라멘트 와인딩 후판 복합재 원통의 좌굴 연구)

  • Moon, Chul-Jin;Hur, Seong-Hwa;Ahn, Jung-Hee;Kweon, Jin-Hwe;Choi, Jin-Ho;Cho, Jong-Rae;Cho, Sang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.147-155
    • /
    • 2009
  • The buckling and failure of filament wound thick composite cylinders under external hydrostatic pressure were investigated by the finite element analysis and test. ACOS, MSC.NASTRAN, and MSC.MARC were used for finite element analysis. T700 carbon-epoxy filament wound composite cylinders were fabricated to have winding angles of $[\pm30/90]_{FW}$, $[\pm45/90]_{FW}$, $[\pm60]_{FW}$, $[\pm60/90]_{FW}$, and tested to verify the finite element analysis. Among the softwares, ACOS predicted buckling load the best with about 1.7~14.3% deviation from test. Analysis and test shows cylinders do not recover the initial buckling pressure after buckling and directly lead to final failure.

A Study on the Buckling Characteristics of Pipe Support(V6) (파이프서포트(V6)의 좌굴특성에 관한 연구)

  • Paik, Shin-Won;Song, In-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.59-62
    • /
    • 2011
  • Among the accidents and failures that occur during concrete construction, many are formwork failures which usually happen when concrete is being placed. A system of formwork filled with wet concrete has its weight at the top and is not basically a stable structure. Slab formwork consists of sheathing, stringer, hanger and shore. There are several types of adjustable shores. In construction site, pipe supports are usually used as a shore of slab formwork. In this study, pipe support systems with/without horizontal connector were measured by buckling test. Buckling load of respective pipe support system was analyzed by structural analysis program(MIDAS). Buckling load of pipe support with/without horizontal connector was got by test and structural analysis. According to these results, we know that horizontal connector made pipe support system very safe. Buckling load of pipe support with horizontal connector is 56% higher than that without horizontal connector. So horizontal connector is important in slab formwork systems. Finally, the present study results will be used to design slab formwork system safely in the construction sites.

Experimental investigations on the failure modes of ring-stiffened cylinders under external hydrostatic pressure

  • Cho, Sang-Rai;Muttaqie, Teguh;Do, Quang Thang;Kim, Sinho;Kim, Seung Min;Han, Doo-Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.6
    • /
    • pp.711-729
    • /
    • 2018
  • This paper reports on the experimental investigations on the failure modes of ring-stiffened cylinder models subjected to external hydrostatic pressure. Nine models were welded from general structural steel. The shells were initially formed by cold-rolling, and flat-bar ring frames were welded to the shell. The hydrostatic pressure tests were conducted by using water as the medium in pressure chambers. The details of the preparation and main test were briefly explained. The investigation identified the consequence of the structural failure modes, including: shell yielding, local shell buckling between ring stiffeners, overall buckling of the shell together with the stiffeners, and interactive buckling mode combining local and overall buckling. In addition, the ultimate strengths were predicted by using existing design codes. Non-linear numerical computations were also conducted by employing the actual imperfection coordinates. Finally, accuracy and reliability of the predictions of design formulae and numerical were substantiated with the test results.

A Pressure Vessel Design and Structural Analysis of a Semi-Autonomous Underwater Vehicle(SAUV) (복합재 반자율 무인잠수정(SAUV)의 내압선체 설계 및 구조해석)

  • Joung, Tae-Hwan;Lee, Chong-Moo;Hong, Seok-Won;An, Chin-Woo;Kim, Tae-Wook;Kim, Jin-Bong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.34-39
    • /
    • 2002
  • A Semi-Autonomous Underwater Vehicle (SAUV) capable of simple work at sea bed is under development in KRISO-KORDI. A pressure vessel of SAUV which is composed of FRP was manufactured to load electronic equipments. The objective of this paper is to verify the safety of the pressure vessel through conducting the structural analysis and test in pressure tank. Strain and stress under unit load were obtained by using ANSYS in the linear structural analysis. And local buckling analysis was performed with NASTRAN for the middle cylindrical hull. For the pressure test, strains were measured at three point. We found that the results by linear structural analysis and experiment are coincide well at the points where buckling does not occur. Maximum depth was estimated to be 250m by the local buckling analysis.

  • PDF

Experimental Study on Performance Evaluation of Steel Frame with Buckling Control Brace (좌굴제어 가새를 가진 가새골조의 성능향상에 관한 실험적 연구)

  • Lee, Sang-Ju;Han, Sang-Eul;Noh, Sam-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.181-188
    • /
    • 2007
  • This research presents two methods to prevent local buckling from circular tube brace and then verify their performance capacity through a cyclic loading test. As control methods on local buckling, one is to restrict local buckling as attaching cover plate at range of buckling. And the another is to exclude danger of buckling as inserting contraction device with rod and spring at the center of brace. The purpose of this research is to develop structural device for restriction of local buckling or for exclusion of its. And we investigate appliance of suggested methods through an experiment. We also estimate the improvement of performance capacity in a quantitative respect.

Simplified method for prediction of elastic-plastic buckling strength of web-post panels in castellated steel beams

  • Liu, Mei;Guo, Kangrui;Wang, Peijun;Lou, Chao;Zhang, Yue
    • Steel and Composite Structures
    • /
    • v.25 no.6
    • /
    • pp.671-684
    • /
    • 2017
  • Elastic-plastic shear buckling behaviors of the web-post in a Castellated Steel Beam (CSB) with hexagonal web openings under vertical shear force were investigated further using Finite Element Model (FEM) based on a sub-model, which took the upper part of the web-post under horizontal shear force to represent the whole web-post under vertical shear force. A simplified design method for the web-post elastic-plastic shear buckling strength was proposed based on simulation results of the sub-model. Proper boundary conditions were applied to the sub-model to assure that its behaviors were identical to those of the whole web-post. The equation to calculate the thin plate elastic shear buckling strength was adopted as the basic form to build the design equation for elastic-plastic buckling strength of the sub-model. Parameters that might affect the elastic-plastic shear buckling strength of the whole web-post were studied. After obtaining the vertical shear buckling strength of a sub-model through FEM, the shear buckling coefficient k can be obtained through the back analysis. A practical calculation method for k was proposed through curving fitting the parameter study results. The elastic-plastic shear buckling strength of the web-post calculated using the proposed shear buckling coefficient k agreed well with that obtained from the FEM and test results. And it was more precise than those obtained from EC3 based on the strut model.

Buckling Behavior of API-X80 Linepipe (API-X80 라인파이프의 좌굴 안정성 평가)

  • Cho, Woo-Yeon;Ahn, Seong-So;Yoon, Tae-Yang;Yoo, Jang-Yong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.211-216
    • /
    • 2007
  • The objective of this paper is to present the results of an experimental and a finite-element investigation into the behavior of X80 grade pipes subjected to bending. For the pipe specimens comprising the test series, different D/t is applied to be representative of those that can be expected in the field. Results from the numerical models are checked against the observations in the testing program and the ability of numerical solutions to predict pipe moment capacity. curvatures. and buckling modes is established. A finite-element model was developed using the finite-element simulator to predict the local buckling behavior of pipes. The comparison between the numerical and the experimental results demonstrates the ability of the analytical model to predict the local buckling behavior of pipes when deformed well into the post-yield range.

  • PDF

Crippling Test of Graphite/Epoxy Stringers (Graphite/Epoxy 스트링거의 크리플링 실험)

  • 최상민;권진회
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.157-160
    • /
    • 2000
  • In author's previous paper, a finite element algorithm was presented to calculate the buckling and crippling stresses of composite laminated stringers. In this study, for the validation of the finite element analysis, Z-section composite stringers of different lengths and flange-widths were tested in axial compression. The stacking sequence of graphite/epoxy is [$\pm$45/0/90]s. Strain gages were attached to each specimen to get the strain response. Deflection and end-shortening were obtained by a displacement transducer. The buckling and crippling loads are determined from the strain response, load vs. end-shortening curves, and load vs. out-of-plane deflection curves. Comparison between finite element and experimental results shows good agreement in the buckling, local buckling, and crippling stresses.

  • PDF