• 제목/요약/키워드: Buck Converter

검색결과 673건 처리시간 0.034초

0.18um CMOS 공정을 이용한 강압형 DC-DC 컨버터 보호회로 구현 및 측정 (Implementation and Measurement of Protection Circuits for Step-down DC-DC Converter Using 0.18um CMOS Process)

  • 송원주;송한정
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.265-271
    • /
    • 2018
  • DC-DC buck converter is a critical building block in the power management integrated circuit (PMIC) architecture for the portable devices such as cellular phone, personal digital assistance (PDA) because of its power efficiency over a wide range of conversion ratio. To ensure a safe operation, avoid unexpected damages and enhance the reliability of the converter, fully-integrated protection circuits such as over voltage protection (OVP), under voltage lock out (UVLO), startup, and thermal shutdown (TSD) blocks are designed. In this paper, these three fully-integrated protection circuit blocks are proposed for use in the DC-DC buck converter. The buck converter with proposed protection blocks is operated with a switching frequency of 1 MHz in continuous conduction mode (CCM). In order to verify the proposed scheme, the buck converter has been designed using a 180 nm CMOS technology. The UVLO circuit is designed to track the input voltage and turns on/off the buck converter when the input voltage is higher/lower than 2.6 V, respectively. The OVP circuit blocks the buck converter's operation when the input voltage is over 3.3 V, thereby preventing the destruction of the devices inside the controller IC. The TSD circuit shuts down the converter's operation when the temperature is over $85^{\circ}C$. In order to verify the proposed scheme, these protection circuits were firstly verified through the simulation in SPICE. The proposed protection circuits were then fabricated and the measured results showed a good matching with the simulation results.

Time Domain Based Digital Controller for Buck-Boost Converter

  • Vijayalakshmi, S.;Sree Renga Raja, T.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1551-1561
    • /
    • 2014
  • Design, Simulation and experimental analysis of closed loop time domain based Discrete PWM buck-boost converter are described. To improve the transient response and dynamic stability of the proposed converter, Discrete PID controller is the most preferable one. Discrete controller does not require any precise analytical model of the system to be controlled. The control system of the converter is designed using digital PWM technique. The proposed controller improves the dynamic performance of the buck-boost converter by achieving a robust output voltage against load disturbances, input voltage variations and changes in circuit components. The converter is designed through simulation using MATLAB/Simulink and performance parameters are also measured. The discrete controller is implemented, and design goal is achieved and the same is verified against theoretical calculation using LabVIEW.

Control and Design of a Arc Power Supply for KSTAR's the Neutral Beam Injection

  • Ryu, Dong-Kyun;Lee, Hee-Jun;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.216-226
    • /
    • 2015
  • The neutral beam injection generate ultra-high temperature energy in the tokamak of nuclear fusion. The neutral beam injection make up arc power supply, filament power supply and acceleration & deceleration power supply. The arc power supply has characteristics of low voltage and high current. Arc power supply generate arc through constant output of voltage and current. So this paper proposed suitable buck converter for low voltage and high current. The proposed buck converter used parallel switch because it can be increased capacity and decrease conduction loss. When an arc generated, the neutral beam injection chamber occur high voltage. And it will break output capacitor of buck converter. Therefore the output capacitor was removed in the proposed converter. Thus the proposed converter should be designed for the characteristics of low voltage and high current. Also, the arc power supply should be guaranteed for system stability. The proposed parallel buck converter enables the system stability of the divided low output voltage and high current. The proposed converter with constant output be the most important design of the output inductor. In this paper, designed arc power supply verified operation of system and stability through simulation and prototype. After it is applied to the 288[kW] arc power supply for neutral beam injection.

박막 인덕터를 이용한 영전압 스위칭 Clamp Voltage Buck 컨버터에 관한 연구 (A ZVS-CV Buck Converter using Thin-Film Inductor)

  • 김영재;김희준;오원석
    • 전자공학회논문지SC
    • /
    • 제37권1호
    • /
    • pp.56-63
    • /
    • 2000
  • Buck 컨버터는 간단한 회로구조와 뛰어난 안정성으로 인하여 DC-DC 컨버터 중에서 가장 많이 이용되는 Topology이다. 그러나 박막 인버터를 기존의 buck 컨버터에 이용하는 경우 박막 인덕터의 인덕턴스가 기본적으로 작은 값이 되므로 최적의 리플전압을 얻기 위해서는 필요이상으로 주파수를 높일 필요가 있으며 이 경우 스위칭손실에 의한 컨버터의 효율저하를 초래하게 된다. 본 논문에서는 이러한 문제점을 해결하기 위하여 박막 인버터의 낮은 인덕턴스 값을 이용하여 스위치에 있어서 영전압 스위칭동작을 구현함으로써 컨버터의 효율을 상승시킬 수 있는 1W급 ZVS-CV Buck 컨버터를 제안하였으며, 실험과 손실해석을 통하여 박막 인덕터를 이용한 ZVS-CV Buck 컨버터의 정상동작을 확인하였고 기존의 Buck 컨버터 보다 효율이 약 4% 향상됨을 입증하였다.

  • PDF

소프트 스위칭 방식을 적용한 고효율 인터리브드 벅 컨버터 (A New High Efficiency Interleaved Buck Converter with Soft-switching Scheme)

  • 김낙윤;최현칠
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.116-123
    • /
    • 2014
  • In this paper, a soft-switching scheme for the PWM interleaved buck converter(IBC) is newly proposed to obtain the advantages of both the conventional PWM interleaved buck and resonant converters such as ease of control, reduced switching losses and stresses, and low EMI. To obtain the soft-switching action, the proposed scheme employs an auxiliary circuit, which is added to the conventional interleaved buck converter and used to achieve soft-switching for both the main switches and the output diodes while not incurring any additional losses due to the auxiliary circuit itself. In this paper, the basic operations are discussed and design guidelines are presented. And through the experimental results, the usefulness of the proposed converter is verified.

Soft Switching방식 고역률 강압형 컨버터 (Soft Switching High Power Factor Buck Converter)

  • 구헌회;조기연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.243-246
    • /
    • 1997
  • In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, a input capacitor can be small enough to filter input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn of of the switching device is a zero current switching(ZCS) and high power factor input is obtained. In addition, zero voltage switching(ZVS) at turn of is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontious conduction mode operation.

  • PDF

디지털 제어기에 의한 강압형 및 승압형 DC-DC 컨버터의 동시제어 (A Study on the Simultaneous Control of Buck and Boost DC-DC Converter by Digital Controller)

  • 박효식;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권3호
    • /
    • pp.141-146
    • /
    • 2001
  • This paper presents a one digital controller two topology PWM DC-DC converter that controls, simultaneously, the separate Buck converter and boost converter with the different specification by using an inexpensive and efficient 8 bit micro-controller. One timer interrupt is used for the detection of output feedback voltage, and other two timer interrupts are used for the generation of PWM waveform for Buck and Boost converter. The control characteristics of one digital controller two topology PWM DC-DC converter is validated by experimental results.

  • PDF

하나의 스위치를 사용한 영전압-전류 스위칭 벅 컨버터 (Zero Voltage and Zero Current Switching Buck Converter Using a Single Swi)

  • 김기준;김태웅;이성백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1866-1868
    • /
    • 1998
  • This paper propose zero voltage and zero current switching buck converter using a single switch. This converter is electrically equivalent to two basic buck converter in a cascade. Proposed converter is switching at high frequency and operate in high efficiency at wide load range due to resonant switching.

  • PDF

Cascaded Buck-Boost 컨버터를 이용한 태양광 모듈 집적형 저전압 배터리 충전 장치 개발 (Development of PV Module Integrated Type Low Voltage Battery Charger using Cascaded Buck-Boost Converter)

  • 김동희;이희서;이영달;이은주;이태원;이병국
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.471-477
    • /
    • 2012
  • In this paper, in order to use module integrated converter using cascaded buck-boost converter for a low battery charger in stand-alone system, a charging algorithm which considers photovoltaic and battery status and PWM controllers which are changed according to charging modes are proposed. The proposed algorithm consists of constant current mode, constant voltage mode and maximum power point tracking mode which enables the battery to charge with maximum power rate. This paper also presents design of cascaded buck-boost converter that is the photovoltaic charger system. A 150W prototype system is built according to verify proposed the charger system and the algorithm.

Modeling and Analysis of the Fractional Order Buck Converter in DCM Operation by using Fractional Calculus and the Circuit-Averaging Technique

  • Wang, Faqiang;Ma, Xikui
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1008-1015
    • /
    • 2013
  • By using fractional calculus and the circuit-averaging technique, the modeling and analysis of a Buck converter with fractional order inductor and fractional order capacitor in discontinuous conduction mode (DCM) operations is investigated in this study. The equivalent averaged circuit model of the fractional order Buck converter in DCM operations is established. DC analysis is conducted by using the derived DC equivalent circuit model. The transfer functions from the input voltage to the output voltage, the duty cycle to the output voltage, the input impedance, and the output impedance of the fractional order Buck converter in DCM operations are derived from the corresponding AC-equivalent circuit model. Results show that the DC equilibrium point, voltage ratio, and all derived transfer functions of the fractional order Buck converter in DCM operations are affected by the inductor order and/or capacitor order. The fractional order inductor and fractional order capacitor are designed, and PSIM simulations are performed to confirm the correctness of the derivations and theoretical analysis.