Journal of Dental Rehabilitation and Applied Science
/
v.21
no.2
/
pp.169-182
/
2005
The purpose of this study was to compare the stress distribution around the surrounding bone according to the splinted and non-splinted conditions on the finite element models of the two implant crowns with the different vertical bone level. The finite element model was designed with the parallel placement of the two fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st and 2nd molars. As the bone quality, the inner cancellous bone and the outer 2 mm cortical bone were designed, and the cortical and cancellous bone were assumed to be perfectly bonded to the implant fixture. The splinted model(Model 1) had 2 mm contact surface and the non-splinted model(Model 2) had $8{\mu}m$ gap between two implant crowns. Two group (Splinted and non-splinted) was loaded with 200 N magnitude in the vertical and oblique directions on the loading point position on the central position of the crown, the 2 mm and 4 mm buccal offset point from the central position. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual and mesio-distal sections. The results were as follows; 1. In the vertical loading condition of central position, the stress was distributed on the cortical bone and the cancellous bone around the thread of the fixture in the splinted and non-splinted models. In the oblique loading condition, the stress was concentrated toward the cortical bone of the fixture neck, and the neck portion of 2nd molar in the non-splinted model was concentrated higher than that of 1st molar compared to the splinted model. 2. In the 2 mm buccal offset position of the vertical loading compared to the central vertical loading, stress pattern was shifted from apical third portion of the fixture to upper third portion of that. In the oblique loading condition, the stress was distributed over the fixture-bone interface. 3. In the 4 mm buccal offset position of the vertical loading, stress pattern was concentrated on the cortical bone around the buccal side of the fixture thread and shifted from apical third portion of the fixture to upper third portion of that in the splinted and non-splinted models. In the oblique loading, stresses pattern was distributed to the outer position of the neck portion of the fixture thread on the mesio-distal section in the splinted and non-splinted models. Above the results, it was concluded that the direction of loading condition was a key factor to effect the pattern and magnitude of stress over the surrounding bone of the fixture under the vertical and oblique loading conditions, although the type with or without proximal contact did not effect to the stress distribution.
The purpose of this study is to compare the healing aspects of the use of ePTFE membrane alone versus combination treatment of ePTFE membrane and bone grafts on class II furcation defects. Seventeen defects were applied ePTFE membrane alone on mxillary molar buccal class II furcation defects as Group I, seventeen defects were applied ePTFE membrane and bone grafts on maxillary molar buccal class II furcation defects as Group II, twenty-three defects were applied ePTFE membrane alone on mandibular molar buccal class II furcation defects as Group III, twenty defects were applied ePTFE membrane and bone grafts on mandibular molar buccal class II furcation defects as Group IV . Measurements were made to determine clinical attachment level, probing depth, gingival depth, SBI, mobility at baseline, 3, 6, 12 months postoperatively. Additional measurements were made to determine membrane exposure level at surgery, 1, 2, 6 weeks postoperatively. And then healing patterns and postoperative complications were evaluated. The result as follows : There were statistically significant differences in probing depth reduction, clinical attachment gain, mobility reduction at values of 3, 6, 12 months postoperatively compared to values of baseline(p<0.05), whereas no significant differences in SBI and gingival recession. In group II, membrane exposure level was increased at 1, 2, 6 weeks postoperatively compared to value of baseline(p<0.05). There were statistically significant differences in changes of probing depth at 3, 6, 12 months postoperatively in combination groups of ePTFE membrane and bone graft compared to groups of ePTFE membrane alone(p<0.05). The vast majority of cases fall into typical healing and delayed healing response when membranes were removed in all groups. Pain and swelling were common postoperative complications. In conclusion, this study was showed more effective healing aspects in combination treatment of ePTFE membrane and bone graft than ePTFE membrane alone and on mandibular molar class II furcation defects than maxillary molar.
Kim, Young-Kyun;Yun, Pil-Young;Oh, Ji-Su;Kim, Su-Gwan
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
v.40
no.4
/
pp.188-194
/
2014
For large membrane perforations that develop during sinus-bone grafting, we performed repairs using a pedicled buccal fat pad and a resorbable collagen membrane simultaneously with the bone graft. This study included eight patients. Postoperative maxillary sinusitis developed in two patients, which we managed with incision and drainage, and antibiotics. Ultimately, six patients received 12 implants, three of which failed (75% success). Implant replacement was performed after the removal of the failed replacement, at which point the prosthetic treatment was considered complete. In all of the six cases that we were able to follow-up with, the sinus-bone graft was healing favorably. We observed that the sinus bone height decreased gradually with time. Based on these case series, we conclude that our procedure of repairing large sinus-membrane perforations with a pedicled buccal fat pad and a collagen membrane is a reliable technique.
Purpose : The purpose of this study was to propose standard values for alveolar and basal bone in normal adult mandibles, and radiologically analyze the remodeling process of the edentulous mandible by examining molar areas and comparing them to the established normal values. Materials and Methods : Panoramic and CT scans of mandible were performed on 20 normal adults and 20 edentulous or partially edentulous adults. In both groups, arch half diameter and distance of alveolar bone were measured. Also the distance from the mandibular canal to the caudal edges, the buccal and lingual external borders of basal bone, were measured. A statistical comparison between the mean values of normal and edentulous mandibles was carried out in the selected areas. Results : There was evidence of decreasing arch half diameter and distance in the edentulous mandible, but statistically no significant change was seen between the normal and edentulous alveolar bone. There was evidence of decreasing buccal basal bone and increasing in the lingual basal bone in the edentulous mandible. A statistically significant difference between normal and edentulous mandibles was noted in the buccal basal bone. Conclusion: There was an inward and forward atrophic change of the edentulous mandibular molar area compared to the control. CT scanning required the use of sophisticated and expensive procedures to analyze the remodeling process of edentulous mandibles. Consequently, the development and application of a more simplified and objective radiographic procedure for broad and long-term study of remodeling procedures of edentulous mandible was recommended.
Purpose: The primary objective of this study was to analyze the thickness and height of alveolar bone around the maxillary and mandibular incisors. Additionally, this study aimed to compare bone parameters between Caucasian (CC) and African American (AA) female patients. Materials and Methods: In this retrospective pilot study, 50 female subjects(25 CC and 25 AA) were included. The inclusion criteria were AA or CC women between the ages of 18 and 50 with a normo-divergent facial pattern and Angle's class I, end-on class II, or mild class III malocclusion. The distance from the cementoenamel junction (CEJ) to the buccal and lingual alveolar crest; the alveolar ridge thickness at the mid-root and apex; and the buccal and lingual bone thickness at 3, 6, and 9mm from the CEJ were measured. Results: No significant difference was found (P>0.05) in the cortical bone thickness at 3mm, 6mm, or 9mm from the alveolar crest between CC and AA populations for most measurements. A significant difference in bone thickness was found (P<0.05) for the lingual surface of the central incisor, with maxillary bone thickness found to be higher than mandibular bone thickness. The measurements of lingual thickness were larger than those of buccal thickness for both races. Conclusion: There were no differences in maxillomandibular anterior alveolar bone measurements between normo-divergent adult AA and CC women, except for a few parameters at varying locations. However, future studies can be planned based the current pilot study data, which may provide valuable information.
Purpose: The aim of this study was to determine the effect of overlaying titanium mesh (TM) with an adjunctive collagen membrane (CM) for preserving the buccal bone when used in association with immediate implant placement in dogs. Methods: Immediate implant placements were performed in the mesial sockets of the third premolars of five dogs. At one site the TM was attached to the fixture with the aid of its own stabilizers and then covered by a CM (CM group), while the contralateral site received only TM (TM group). Biopsy specimens were retrieved for histologic and histomorphometric analyses after 16 weeks. Results: All samples exhibited pronounced buccal bone resorption, and a high rate of TM exposure was noted (in three and four cases of the five samples in each of the TM and CM groups, respectively). A dense fibrous tissue with little vascularity or cellularity had infiltrated through the pores of the TM irrespective of the presence of a CM. The distances between the fixture platform and the first bone-implant contact and the bone crest did not differ significantly between the TM and CM groups. Conclusions: Our study suggests that the additional use of a CM over TM does not offer added benefit for mucosal healing and buccal bone preservation.
The endodontic-periodontic combined lesions have been difficult to get correct diagnosis and predictable treatment. This study was to make the experimental endodontic-periodontic combined defects in dogs for the study of the periodontal regeneration and to evaluate the efficacy of the enamel matrix protein and e-PTFE membrane in the experimental endodontic-periodontic combined defects. 5 mongrel dogs were used. The pulp chambers were opened and the plaque was inserted into the chambers to induce the periapical lesions on the mandibular second, third and fourth premolars of the dogs. 1 month later, the root canal treatments were done with gutta perch a and ZOE sealer. On the day of surgery, the periapical defects were standardized by trephine bur. The buccal dehiscence defects were made by the dental bur and bone chisels. The apicoectomy with retrofilling was done. The prepared roots were randomly selected for test and control groups. In the experimental groups, the enamel matrix derivative and e-PTFE membrane were used. Nothing was placed on the control group. Fluroscent labelling was used to evaluate the bone formation. After 4 and 12 weeks, the dogs were sacrificed and undecalcified sections were prepared and stained with toluidine blue. Those histologic sections were examined by fluorescent microscopy and light microscopy. The results were as follows. 1. In the control group, new bone was formed in the periapical defects and scarcely in the buccal dehiscence defects. New cementum was not detected at 4 and 12 weeks. 2. In the experimental groups, new bone, new cementum and periodontal ligament were found in the periapical and buccal dehiscence defects. The relative amount and the quality of the new bone, new cementum and periodontal ligament tissue that had formed on the experimental groups were superior to those of the control group. 3. The current observation implicated that e-PTFE membrane and enamel matrix protein could be the effective tools for the guided tissue regeneration of the endo-perio combined defects.
Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.
An overall reduction in the horizontal and vertical dimensions occurs following tooth extraction and the resorption of the buccal part of the ridge is more pronounced than the lingual part. Thus, the resulting morphology of the healed alveolar ridge is often presenting with a discrepancy in bone height between the buccal and lingual aspects of the ridge. The implant with a sloped marginal configuration that is designed to match the sloped contour of the alveolar ridge provides the opportunity to maintain the buccal-lingual bone discrepancy and soft tissue around the implant. This paper introduces the OsseoSpeed TX Profile implants with sloped marginal configuration and explains the characteristics and clinical meanings of those implants.
Kim, Kyu-Tag;Yu, Sun-Kyoung;Lee, Myoung-Hwa;Lee, Yun-Ho;Kim, Hye-Ryun;Kim, Heung-Joong
International Journal of Oral Biology
/
v.36
no.2
/
pp.65-70
/
2011
Recently, mini-implant is popular in the orthodontic treatment due to its simplicity and convenient surgical procedure. The objective of this study is to provide the anatomical guideline for mini-implant placement by analysing the cortical bone thickness in Korean. Hemi-sections of sixteen maxillae and twenty-two mandibles with normal teeth were used. Interdental areas between the 1st premolar and the 2nd premolar (Group 1), the 2nd premolar and the 1st molar (Gruop 2), and the 1st molar and the 2nd molar (Group 3) were sectioned and then scanned. After setting the axis of teeth, the cortical bone thickness was measured at the distance of 2 mm, 4mm, 6 mm, and 8 mm from alveolar crest. The mean thickness of cortical bone in the maxilla according to distance from alveolar crest was $1.30\;{\pm}\;0.63\; mm$ (2 mm), $1.49\;{\pm}\;0.62\; mm$ (4mm), $1.72\;{\pm}\;0.64\; mm$ (6mm), and $1.90\;{\pm}\;0.90\; mm$ (8 mm) at the buccal side and $1.33\;{\pm}\;0.47 \;mm$, $1.31\;{\pm}\;0.45\; mm$, $1.37\;{\pm}\;0.55\; mm$, and $1.39\;{\pm}\;0.58 \;mm$ at the palatal side. In the mandible, that was $3.14\;{\pm}\;1.71 \;mm$, $4.31\;{\pm}\;2.22 \;mm$, $4.23\;{\pm}\;1.94 \;mm$, and $4.30\;{\pm}\;1.57\; mm$ at the buccal side and $1.98\;{\pm}\;0.88 \;mm$, $2.79\;{\pm}\;1.01\; mm$, $3.35\;{\pm}\;1.27$ mm, and $3.93\;{\pm}\;1.38\; mm$ at the lingual side. The buccal cortical bone thickness in the maxilla was decreased from Group 1 to Group 3, while the thickness of palatal side was no change. In the mandible, it did not show a tendency at the buccal side and it was decreased from Group 1 to Group 3 without significant difference at the lingual side. Therefore, the buccal side of the Group 1 and Group 2 in both the maxilla and mandible seems to be the most appropriate site for a mini-implant placement with taking the stability and retention.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.