• Title/Summary/Keyword: Buccal bone

Search Result 321, Processing Time 0.024 seconds

Stress Analysis on the Splinted Conditions of the Two Implant Crowns with the Different Vertical Bone Level (치조골 높이가 다른 2개 임플란트 금관의 고정연결 조건에 따른 응력분석)

  • Jeon, Chang-Sik;Jeong, Sin-Young;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.169-182
    • /
    • 2005
  • The purpose of this study was to compare the stress distribution around the surrounding bone according to the splinted and non-splinted conditions on the finite element models of the two implant crowns with the different vertical bone level. The finite element model was designed with the parallel placement of the two fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st and 2nd molars. As the bone quality, the inner cancellous bone and the outer 2 mm cortical bone were designed, and the cortical and cancellous bone were assumed to be perfectly bonded to the implant fixture. The splinted model(Model 1) had 2 mm contact surface and the non-splinted model(Model 2) had $8{\mu}m$ gap between two implant crowns. Two group (Splinted and non-splinted) was loaded with 200 N magnitude in the vertical and oblique directions on the loading point position on the central position of the crown, the 2 mm and 4 mm buccal offset point from the central position. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual and mesio-distal sections. The results were as follows; 1. In the vertical loading condition of central position, the stress was distributed on the cortical bone and the cancellous bone around the thread of the fixture in the splinted and non-splinted models. In the oblique loading condition, the stress was concentrated toward the cortical bone of the fixture neck, and the neck portion of 2nd molar in the non-splinted model was concentrated higher than that of 1st molar compared to the splinted model. 2. In the 2 mm buccal offset position of the vertical loading compared to the central vertical loading, stress pattern was shifted from apical third portion of the fixture to upper third portion of that. In the oblique loading condition, the stress was distributed over the fixture-bone interface. 3. In the 4 mm buccal offset position of the vertical loading, stress pattern was concentrated on the cortical bone around the buccal side of the fixture thread and shifted from apical third portion of the fixture to upper third portion of that in the splinted and non-splinted models. In the oblique loading, stresses pattern was distributed to the outer position of the neck portion of the fixture thread on the mesio-distal section in the splinted and non-splinted models. Above the results, it was concluded that the direction of loading condition was a key factor to effect the pattern and magnitude of stress over the surrounding bone of the fixture under the vertical and oblique loading conditions, although the type with or without proximal contact did not effect to the stress distribution.

A Comparative Study of Clinical Healing Aspects in GTR Treatment on Class II Furcation Defects (치근이개부 II급 병변에서 조직유도재생술의 임상적 치유양상의 비교)

  • Moon, Sun-Young;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.519-540
    • /
    • 1999
  • The purpose of this study is to compare the healing aspects of the use of ePTFE membrane alone versus combination treatment of ePTFE membrane and bone grafts on class II furcation defects. Seventeen defects were applied ePTFE membrane alone on mxillary molar buccal class II furcation defects as Group I, seventeen defects were applied ePTFE membrane and bone grafts on maxillary molar buccal class II furcation defects as Group II, twenty-three defects were applied ePTFE membrane alone on mandibular molar buccal class II furcation defects as Group III, twenty defects were applied ePTFE membrane and bone grafts on mandibular molar buccal class II furcation defects as Group IV . Measurements were made to determine clinical attachment level, probing depth, gingival depth, SBI, mobility at baseline, 3, 6, 12 months postoperatively. Additional measurements were made to determine membrane exposure level at surgery, 1, 2, 6 weeks postoperatively. And then healing patterns and postoperative complications were evaluated. The result as follows : There were statistically significant differences in probing depth reduction, clinical attachment gain, mobility reduction at values of 3, 6, 12 months postoperatively compared to values of baseline(p<0.05), whereas no significant differences in SBI and gingival recession. In group II, membrane exposure level was increased at 1, 2, 6 weeks postoperatively compared to value of baseline(p<0.05). There were statistically significant differences in changes of probing depth at 3, 6, 12 months postoperatively in combination groups of ePTFE membrane and bone graft compared to groups of ePTFE membrane alone(p<0.05). The vast majority of cases fall into typical healing and delayed healing response when membranes were removed in all groups. Pain and swelling were common postoperative complications. In conclusion, this study was showed more effective healing aspects in combination treatment of ePTFE membrane and bone graft than ePTFE membrane alone and on mandibular molar class II furcation defects than maxillary molar.

  • PDF

Prognosis of closure of large sinus membrane perforations using pedicled buccal fat pads and a resorbable collagen membrane: case series study

  • Kim, Young-Kyun;Yun, Pil-Young;Oh, Ji-Su;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.4
    • /
    • pp.188-194
    • /
    • 2014
  • For large membrane perforations that develop during sinus-bone grafting, we performed repairs using a pedicled buccal fat pad and a resorbable collagen membrane simultaneously with the bone graft. This study included eight patients. Postoperative maxillary sinusitis developed in two patients, which we managed with incision and drainage, and antibiotics. Ultimately, six patients received 12 implants, three of which failed (75% success). Implant replacement was performed after the removal of the failed replacement, at which point the prosthetic treatment was considered complete. In all of the six cases that we were able to follow-up with, the sinus-bone graft was healing favorably. We observed that the sinus bone height decreased gradually with time. Based on these case series, we conclude that our procedure of repairing large sinus-membrane perforations with a pedicled buccal fat pad and a collagen membrane is a reliable technique.

Radiologic assessment of alveolar and basal bone change of partially edentulous mandible (부분 무치악 하악골의 치조골 및 기저골 변화에 관한 방사선학적 평가)

  • Park Chang-Seo;Kim Kee-Deog
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.141-145
    • /
    • 2002
  • Purpose : The purpose of this study was to propose standard values for alveolar and basal bone in normal adult mandibles, and radiologically analyze the remodeling process of the edentulous mandible by examining molar areas and comparing them to the established normal values. Materials and Methods : Panoramic and CT scans of mandible were performed on 20 normal adults and 20 edentulous or partially edentulous adults. In both groups, arch half diameter and distance of alveolar bone were measured. Also the distance from the mandibular canal to the caudal edges, the buccal and lingual external borders of basal bone, were measured. A statistical comparison between the mean values of normal and edentulous mandibles was carried out in the selected areas. Results : There was evidence of decreasing arch half diameter and distance in the edentulous mandible, but statistically no significant change was seen between the normal and edentulous alveolar bone. There was evidence of decreasing buccal basal bone and increasing in the lingual basal bone in the edentulous mandible. A statistically significant difference between normal and edentulous mandibles was noted in the buccal basal bone. Conclusion: There was an inward and forward atrophic change of the edentulous mandibular molar area compared to the control. CT scanning required the use of sophisticated and expensive procedures to analyze the remodeling process of edentulous mandibles. Consequently, the development and application of a more simplified and objective radiographic procedure for broad and long-term study of remodeling procedures of edentulous mandible was recommended.

  • PDF

Comparison of anterior maxillary and mandibular alveolar parameters in African American and Caucasian women: A retrospective pilot study

  • Renaud, Lauren;Gandhi, Vaibhav;West, Cailynn;Gudhimella, Sudha;Janakiraman, Nandakumar
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.175-185
    • /
    • 2021
  • Purpose: The primary objective of this study was to analyze the thickness and height of alveolar bone around the maxillary and mandibular incisors. Additionally, this study aimed to compare bone parameters between Caucasian (CC) and African American (AA) female patients. Materials and Methods: In this retrospective pilot study, 50 female subjects(25 CC and 25 AA) were included. The inclusion criteria were AA or CC women between the ages of 18 and 50 with a normo-divergent facial pattern and Angle's class I, end-on class II, or mild class III malocclusion. The distance from the cementoenamel junction (CEJ) to the buccal and lingual alveolar crest; the alveolar ridge thickness at the mid-root and apex; and the buccal and lingual bone thickness at 3, 6, and 9mm from the CEJ were measured. Results: No significant difference was found (P>0.05) in the cortical bone thickness at 3mm, 6mm, or 9mm from the alveolar crest between CC and AA populations for most measurements. A significant difference in bone thickness was found (P<0.05) for the lingual surface of the central incisor, with maxillary bone thickness found to be higher than mandibular bone thickness. The measurements of lingual thickness were larger than those of buccal thickness for both races. Conclusion: There were no differences in maxillomandibular anterior alveolar bone measurements between normo-divergent adult AA and CC women, except for a few parameters at varying locations. However, future studies can be planned based the current pilot study data, which may provide valuable information.

The effect of overlaying titanium mesh with collagen membrane for ridge preservation

  • Lim, Hyun-Chang;Lee, Jung-Seok;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.4
    • /
    • pp.128-135
    • /
    • 2015
  • Purpose: The aim of this study was to determine the effect of overlaying titanium mesh (TM) with an adjunctive collagen membrane (CM) for preserving the buccal bone when used in association with immediate implant placement in dogs. Methods: Immediate implant placements were performed in the mesial sockets of the third premolars of five dogs. At one site the TM was attached to the fixture with the aid of its own stabilizers and then covered by a CM (CM group), while the contralateral site received only TM (TM group). Biopsy specimens were retrieved for histologic and histomorphometric analyses after 16 weeks. Results: All samples exhibited pronounced buccal bone resorption, and a high rate of TM exposure was noted (in three and four cases of the five samples in each of the TM and CM groups, respectively). A dense fibrous tissue with little vascularity or cellularity had infiltrated through the pores of the TM irrespective of the presence of a CM. The distances between the fixture platform and the first bone-implant contact and the bone crest did not differ significantly between the TM and CM groups. Conclusions: Our study suggests that the additional use of a CM over TM does not offer added benefit for mucosal healing and buccal bone preservation.

BONE REGENERATION OF THE EXPERIMENTAL ENDODONTIC-PERIODONTIC COMBINED DEFECTS IN THE MANDIBLES OF THE DOGS (성견 하악의 치주-치근단 실험적 복합병소에서 골조직 재생에 관한 연구)

  • Kim, Jeong-Hye;Baek, Seung-Ho;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.286-298
    • /
    • 1999
  • The endodontic-periodontic combined lesions have been difficult to get correct diagnosis and predictable treatment. This study was to make the experimental endodontic-periodontic combined defects in dogs for the study of the periodontal regeneration and to evaluate the efficacy of the enamel matrix protein and e-PTFE membrane in the experimental endodontic-periodontic combined defects. 5 mongrel dogs were used. The pulp chambers were opened and the plaque was inserted into the chambers to induce the periapical lesions on the mandibular second, third and fourth premolars of the dogs. 1 month later, the root canal treatments were done with gutta perch a and ZOE sealer. On the day of surgery, the periapical defects were standardized by trephine bur. The buccal dehiscence defects were made by the dental bur and bone chisels. The apicoectomy with retrofilling was done. The prepared roots were randomly selected for test and control groups. In the experimental groups, the enamel matrix derivative and e-PTFE membrane were used. Nothing was placed on the control group. Fluroscent labelling was used to evaluate the bone formation. After 4 and 12 weeks, the dogs were sacrificed and undecalcified sections were prepared and stained with toluidine blue. Those histologic sections were examined by fluorescent microscopy and light microscopy. The results were as follows. 1. In the control group, new bone was formed in the periapical defects and scarcely in the buccal dehiscence defects. New cementum was not detected at 4 and 12 weeks. 2. In the experimental groups, new bone, new cementum and periodontal ligament were found in the periapical and buccal dehiscence defects. The relative amount and the quality of the new bone, new cementum and periodontal ligament tissue that had formed on the experimental groups were superior to those of the control group. 3. The current observation implicated that e-PTFE membrane and enamel matrix protein could be the effective tools for the guided tissue regeneration of the endo-perio combined defects.

  • PDF

STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH (치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포)

  • Han, Sang-Un;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

Characteristics and clinical meanings of the implant with a sloped marginal configuration (경사진 상부 형태(sloped marginal configuration)를 가진 임플란트의 특징과 임상적 의미)

  • Kim, Taehyung
    • The Journal of the Korean dental association
    • /
    • v.54 no.5
    • /
    • pp.328-341
    • /
    • 2016
  • An overall reduction in the horizontal and vertical dimensions occurs following tooth extraction and the resorption of the buccal part of the ridge is more pronounced than the lingual part. Thus, the resulting morphology of the healed alveolar ridge is often presenting with a discrepancy in bone height between the buccal and lingual aspects of the ridge. The implant with a sloped marginal configuration that is designed to match the sloped contour of the alveolar ridge provides the opportunity to maintain the buccal-lingual bone discrepancy and soft tissue around the implant. This paper introduces the OsseoSpeed TX Profile implants with sloped marginal configuration and explains the characteristics and clinical meanings of those implants.

  • PDF

Cortical Bone Thickness for Mini-implant Placement in Korean

  • Kim, Kyu-Tag;Yu, Sun-Kyoung;Lee, Myoung-Hwa;Lee, Yun-Ho;Kim, Hye-Ryun;Kim, Heung-Joong
    • International Journal of Oral Biology
    • /
    • v.36 no.2
    • /
    • pp.65-70
    • /
    • 2011
  • Recently, mini-implant is popular in the orthodontic treatment due to its simplicity and convenient surgical procedure. The objective of this study is to provide the anatomical guideline for mini-implant placement by analysing the cortical bone thickness in Korean. Hemi-sections of sixteen maxillae and twenty-two mandibles with normal teeth were used. Interdental areas between the 1st premolar and the 2nd premolar (Group 1), the 2nd premolar and the 1st molar (Gruop 2), and the 1st molar and the 2nd molar (Group 3) were sectioned and then scanned. After setting the axis of teeth, the cortical bone thickness was measured at the distance of 2 mm, 4mm, 6 mm, and 8 mm from alveolar crest. The mean thickness of cortical bone in the maxilla according to distance from alveolar crest was $1.30\;{\pm}\;0.63\; mm$ (2 mm), $1.49\;{\pm}\;0.62\; mm$ (4mm), $1.72\;{\pm}\;0.64\; mm$ (6mm), and $1.90\;{\pm}\;0.90\; mm$ (8 mm) at the buccal side and $1.33\;{\pm}\;0.47 \;mm$, $1.31\;{\pm}\;0.45\; mm$, $1.37\;{\pm}\;0.55\; mm$, and $1.39\;{\pm}\;0.58 \;mm$ at the palatal side. In the mandible, that was $3.14\;{\pm}\;1.71 \;mm$, $4.31\;{\pm}\;2.22 \;mm$, $4.23\;{\pm}\;1.94 \;mm$, and $4.30\;{\pm}\;1.57\; mm$ at the buccal side and $1.98\;{\pm}\;0.88 \;mm$, $2.79\;{\pm}\;1.01\; mm$, $3.35\;{\pm}\;1.27$ mm, and $3.93\;{\pm}\;1.38\; mm$ at the lingual side. The buccal cortical bone thickness in the maxilla was decreased from Group 1 to Group 3, while the thickness of palatal side was no change. In the mandible, it did not show a tendency at the buccal side and it was decreased from Group 1 to Group 3 without significant difference at the lingual side. Therefore, the buccal side of the Group 1 and Group 2 in both the maxilla and mandible seems to be the most appropriate site for a mini-implant placement with taking the stability and retention.