• Title/Summary/Keyword: Buccal bone

Search Result 320, Processing Time 0.022 seconds

Finite element stress analysis according to the point and surface occlusal loads on the implant prosthesis (임플란트 보철물의 점하중과 면하중에 따른 유한요소법적 응력 분석)

  • Choi, Min-Ho;Kang, Jae-Suek;Boo, Soo-Bung;Oh, Snag-Ho;An, OK-Ju;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.83-94
    • /
    • 2004
  • The purpose of this study was to compare the distributing pattern of stress according to the types of occlusal load on the finite element models of the splinted implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on mandibular first and second molars. The cemented crowns for mandibular first and second molars were made. Three-dimensional finite element model was created with the components of the implant, surrounding bone and cemented crowns. Two types of occlusal load, the point load and the surface load within 0.5 mm radius circle, were applied to the finite element models with 200N magnitude in axial(along the long axis of the implant and oblique(angulation of $30^{\circ}$ to the long axis) directions perpendicular to cuspal incline. Loads were positioned from the center of central fossa and to distance of 2 mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the fixtures and sections. The results were as following : 1. Under axial loading at the central fossa, the stress was distributed along the fixture except for the apical portion, not relative to both point & surface contacts. 2. With offset distance increasing, the highest stresses were concentrated in the neck portion of the fixture. 3. The maximum von Mises stress under the oblique load was greater than that under the axial load. 4. Under the oblique load, the highest stress were concentrated in the buccal side and lingual neck portion of the fixture with offset distance increasing. The results had a tendency to increase the stress on the neck portion of fixture with the offset and oblique loads increasing. The design of occlusal scheme should be allowed to distribute stress axially in maximum intercuspation and to decrease the angulation of cuspal incline.

Effects of remifentanil preconditioning on factors related to uterine contraction in WISH cells

  • Kim, Cheul-Hong;Lee, Sang-Hoon;Kim, Eun-Jung;Ahn, Ji-Hye;Choi, Eun-Ji;Yoon, Ji-Uk;Choi, In-Seok
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.6
    • /
    • pp.343-351
    • /
    • 2019
  • Background: Preterm labor and miscarriage may occur in stressful situations, such as a surgical operation or infection during pregnancy. Pharyngeal and buccal abscess and facial bone fractures are inevitable dental surgeries in pregnant patients. Remifentanil is an opioid analgesic that is commonly used for general anesthesia and sedation. Nonetheless, no study has investigated the effects of remifentanil on amniotic epithelial cells. This study evaluated the effects of remifentanil on the factors related to uterine contraction and its mechanism of action on amniotic epithelial cells. Methods: Amniotic epithelial cells were preconditioned at various concentrations of remifentanil for 1 h, followed by 24-h lipopolysaccharide (LPS) exposure. MTT assays were performed to assess the cell viability in each group. The effects of remifentanil on factors related to uterine contractions in amniotic epithelial cells were assessed using a nitric oxide (NO) assay, western blot examinations of the expression of nuclear factor-kappa B (NF-κB), cyclooxygenase 2 (COX2), and prostaglandin E2 (PGE2), and RT-PCR examinations of the expression of the proinflammatory cytokines interleukin (IL)-1β and tumor necrosis factor-alpha (TNF-α). Results: Remifentanil did not affect viability and nitric oxide production of amniotic epithelial cells. Western blot analysis revealed that remifentanil preconditioning resulted in decreased expressions of NF-κB and PGE2 in the cells in LPS-induced inflammation, and a tendency of decreased COX2 expression. The results were statistically significant only at high concentration. RT-PCR revealed reduced expressions of IL-1β and TNF-α. Conclusions: Preconditioning with remifentanil does not affect the viability of amniotic epithelial cells but reduces the expression of factors related to uterine contractions in situations where cell inflammation is induced by LPS, which is an important inducer of preterm labor. These findings provide evidence that remifentanil may inhibit preterm labor in clinical settings.

Clinical Cases Analysis of Forearm Free Fasciocutaneous Flaps on Oral Cavity Defect Area (구강 결손부에 적용된 요골 유리전완 피부피판 적용례 분석)

  • Kim, Uk-Kyu;Lee, Kwang-Ho;Song, Won-Wook;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Jong-Ryoul;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.324-331
    • /
    • 2010
  • The radial forearm free flap (RFFF) has become a workhorse flap as a means of reconstructing surgical defects in the head and neck region. We have transferred 12 RFFFs with fasciocutaneous type on oral cavity defects in 12 patients after cancer resection and submucous fibrotic lesion ablation from 2005 to 2007 at Department of oral and maxillofacial surgery, Pusan National University Hospital. We reviewed retrospectively patients' charts and followed up the patients. Clinical analysis on the cases with RFFFs focusing on flap morbidity, indications and available vessels was done. The results of study are follows: 1. RFFF could be applied for all kind of defects after resection of tongue, floor of mouth, buccal mucosa, denuded bone of palate, maxilla, and mandible. 2. All free flaps could be used for primary reconstruction. The survival rate of 12 RFFFs was 92%. Partial marginal loss of the flaps was shown as 3 cases among 12 cases. Large size-vessels like superior thyroid artery, facial artery, internal jugular vein were favorable for microvascular anastomosis. 3. Parenteral nutrition instead of nasal L-tube also can be favorable for postoperative a week for better healing of the flap if the patients couldn't be tolerable with nasal tubing. 4. Donor sites with thigh skin graft were repaired with wrist band for 2 weeks. The complications included scarring, abnormal sensation on hand, and reduced grip strength in few patients, but those didn't induce major side effects. 5. Most RFFFs were well healed even if mortality rate of cancer patients was shown as 50% (5/10 persons). The mortality of patients was not correlated with morbidity of the flaps. We could identify the usefulness of RFFF for restoration of oral function, esthetics if the flap design, tissue transfer indications, and well controlled operation are proceeded.

Finite-element investigation of the center of resistance of the maxillary dentition (상악 치아군의 저항중심의 위치에 관한 3차원 유한요소 해석)

  • Jeong, Gwang-Mo;Sung, Sang-Jin;Lee, Kee-Joon;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.83-94
    • /
    • 2009
  • Objective: The aim of this study was to investigate the 3-dimensional position of the center of resistance of the 4 maxillary anterior teeth, 6 maxillary anterior teeth, and the full maxillary dentition using 3-dimensional finite element analysis. Methods: Finite element models included the whole upper dentition, periodontal ligament, and alveolar bone. The crowns of the teeth in each group were fixed with buccal and lingual arch wires and lingual splint wires to minimize individual tooth movement and to evenly disperse the forces to the teeth. A force of 100 g or 200 g was applied to the wire beam extended from the incisal edge of the upper central incisor, and displacement of teeth was evaluated. The center of resistance was defined as the point where the applied force induced parallel movement. Results: The results of study showed that the center of resistance of the 4 maxillary anterior teeth group, the 6 maxillary anterior teeth group, and the full maxillary dentition group were at 13.5 mm apical and 12.0 mm posterior, 13.5 mm apical and 14.0 mm posterior, and 11.0 mm apical and 26.5 mm posterior to the incisal edge of the upper central incisor, respectively. Conclusions: It is thought that the results from this finite element models will improve the efficiency of orthodontic treatment.

An experimental study on the dynamic tooth movement of two molar uprighting springs by calorific machine (두 종류의 구치직립 스프링 사용시 저항원 및 근심경사치의 동적인 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.273-285
    • /
    • 2000
  • The aim of this investigation was to evaluate the differences of two canti-leyer springs by using a new simulation system. This was done using a Calorific machine that compared iron uprighting spring and root uprighting spring. The Calorific machine was designed to allow observation of the whole process of tooth moving, and is composed of three parts(a temperature regulating system, electro-thermodynamic teeth, and an artificial alveolar bone component). The experiment of both mechanics were repeated five times and measured two times. The intra-examiner agreement and inlet-examiner agreement were $96.54\%\;and\;95.73\%$ and these data were statistically tested by paired t-test. The obtained results were as follows. 1. Distal and buccal movement of the anchor teeth were observed greater in the root uprighting spring than the crown uprighting spring. 2. Crown uprighting spring showed distal movement of the crown of lower second molar for 3.29mm but root uprighting spring showed only 1.68mm. 3. Crown uprighting spring exhibited forward movement of mesial and distal root of the lower second molar for 3.91mm, 3.60mm but the root uprighting spring showed 6.76mm, 6.26mm.

  • PDF

A CLINICOSTATISTICAL ANALYSIS OF ORAL CANCER PATIENTS FOR RECENT 8 YEARS (최근 8년간 구강암 환자에 대한 임상통계학적 연구)

  • Kim, Myoung-Yun;Kim, Chin-Soo;Lee, Sang-Han;Kim, Jin-Wook;Jang, Hyun-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.660-668
    • /
    • 2007
  • We investigated 248 patients who were diagnosed as malignant tumor in the department of Oral and maxillofacial Surgery of Kyungpook National University from 1999 to 2006, and following results were obtained. 1. Among 248 patients who have malignant tumor, 164 were men and 84 were women, which made the ratio of male to female 1.95:1. 2. The average age of oral cancer patients was 58.3. 3. As of the primary origin site, lower alveolus and gingiva were the greatest with 70 cases(28.2%), followed by tongue(l6.9%), upper alveolus and gingiva(14.9%), palate(13.7%), mouth floor(9.7%), buccal mucosa(4.8%), retromolar trigone(4.4%), Mx. & Mn. bone(3.2%) and lip(2.8%). 4. As of histologic distribution, squamous cell carcinoma was the greatest with 170 cases(68.6%), followed by sarcoma with 17 cases(6.9%), adenoid cystic carcinoma with 17 cases(6.9%), malignant lymphoma with 15 cases(6.0%), mucoepidermoid carcinoma with 13 cases(5.2%), metastatic carcinoma with 6 cases(2.4%) and malignant melanoma with 4 cases(1.6%). 5. Period between recognition of the symptom and the first visit to hospital was less than 3 months for 58.9% of the patients, and more than 3 months for 41% of the patients. 6. Investigation of whether the patients drink or smoke revealed that the number of non-smoking and non-drinking patients was 63 among 170 patients(37.0%) that were able to investigate. The number of patients who smoke only was 29(17.1%) and both drinking and smoking patients were 78(45.9%). 7. In clinical stage order, Stage IV(61.7%) was found th be the largest, followed by stage I(17.2%), stage II(13%) and stage III(7.8%). 8. The 5-year survival rate of the entire oral cancer patients appeared to be 57.7%. The survival rate was higher in younger group and women had higher survival rate but there was no statistical significance to this. In the aspect of stage, the survival rate was Stage I, Stage II, Stage IV and Stage III in decreasing order. The order according to T classification was the same. In N classification, patients with N0 had the highest survival rate and the survival rate decreased in the order of N1 and N2. Survival rate was especially low in patients with N2.

FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES (Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석)

  • Kim, Joung-Hee;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF

Dimensional change of the healed periosteum on surgically created defects

  • Cho, Eun-Hee;Park, Jung-Chul;Cha, Jae-Kook;Kim, Yong-Tae;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Purpose: The final goal of regenerative periodontal therapy is to restore the structure and function of the periodontium destroyed or lost due to periodontitis. However, the role of periosteum in periodontal regeneration was relatively neglected while bone repair in the skeleton occurs as a result of a significant contribution from the periosteum. The aim of this study is to understand the histological characteristics of periosteum and compare the native periosteum with the repaired periosteum after elevating flap or after surgical intervention with flap elevation. Methods: Buccal and lingual mucoperiosteal flaps were reflected to surgically create critical-size, "box-type" (4 mm width, 5 mm depth), one-wall, intrabony defects at the distal aspect of the 2nd and the mesial aspect of the 4th mandibular premolars in the right and left jaw quadrants. Animals were sacrificed after 24 weeks. Results: The results from this study are as follows: 1) thickness of periosteum showed difference as follows (P<0.05): control group ($0.45{\pm}0.22$ mm)> flap-elevation group ($0.36{\pm}0.07$ mm)> defect formation group ($0.26{\pm}0.03$ mm), 2) thickness of gingival tissue showed difference as follows (P<0.05): defect formation group ($3.15{\pm}0.40$ mm)> flap-elevation group ($2.02{\pm}0.25$ mm) > control group ($1.88{\pm}0.27$ mm), 3) higher cellular activity was observed in defect formation group and flap-elevation groups than control group, 4) the number of blood vessles was higher in defect formation group than control group. Conclusions: In conclusion, prolonged operation with increased surgical trauma seems to decrease the thickness of repaired periosteum and increase the thickness of gingiva. More blood vessles and high cellular activity were observed in defect formation group.

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

Insertion and removal torques according to orthodontic mini-screw design (교정용 미니스크류의 디자인에 따른 식립 및 제거 토오크)

  • Cha, Jung-Yul;Yoon, Tae-Min;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.5-12
    • /
    • 2008
  • Objective: This study was designed to analyze the primary and secondary stability characteristics of orthodontic mini-screws of tapered design when compared with the cylinder mini-screw. Methods: A total of 48 mini-screws were placed into the buccal alveolar bone of the mandible in 6 male beagle dogs. Comparison was made between tapered and cylinder type mini-screws (Biomaterials Korea, Seoul, Korea). Maximum insertion torque (MIT) was measured using a torque sensor (Mark-10, MGT 50, USA) during installation, and maximum removal torque (MRT) was recorded after 3 and 12 weeks of loading. Results: Taper mini-screws showed a higher MIT value of 22.3 Ncm compared with cylinder mini-screw showing 13.6 Ncm (p < 0.001). The MRT of the taper mini-screw showed a significantly higher value of 9.1 Ncm than those of cylinder mini-screw of 5.7 Ncm at 3-weeks after installation (p < 0.05). However, there was no difference in the MRT value between the taper and cylinder mini-screws at 12 weeks of loading. Conclusions: These results showed that the high insertion torque of the taper mini-screw design increases initial stability until 3 weeks of loading, but does not have any effect on the secondary stability at 12 weeks of loading.