• Title/Summary/Keyword: Buccal bone

Search Result 320, Processing Time 0.024 seconds

Efficacy of intraosseous saline injection for pain management during surgical removal of impacted mandibular third molars: a randomized double-blinded clinical trial

  • Jawahar Babu. S;Naveen Kumar Jayakumar;Pearlcid Siroraj
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.3
    • /
    • pp.163-171
    • /
    • 2023
  • Background: Surgical extraction of impacted mandibular third molars is the most common procedure performed by oral surgeons. The procedure cannot be performed effectively without achieving profound anesthesia. During this procedure, patients may feel pain during surgical bone removal (at the cancellous level) or during splitting and luxation of the tooth, despite administration of routine nerve blocks. Administration of intraosseous (IO) lignocaine injections during third molar surgeries to provide effective anesthesia for pain alleviation has been documented. However, whether the anesthetic effect of lignocaine is the only reason for pain alleviation when administered intraosseously remains unclear. This conundrum motivated us to assess the efficacy of IO normal saline versus lignocaine injections during surgical removal of impacted mandibular third molars. The aim of this study was to assess the efficacy of IO normal saline as a viable alternative or adjunct to lignocaine for alleviation of intraoperative pain during surgical removal of impacted mandibular third molars. Methods: This randomized, double-blind, interventional study included 160 patients who underwent surgical extraction of impacted mandibular third molars and experienced pain during surgical removal of the buccal bone or sectioning and luxation of the tooth. The participants were divided into two groups: the study group, which included patients who would receive IO saline injections, and the control group, which included patients who would receive IO lignocaine injections. Patients were asked to complete a visual analog pain scale (VAPS) at baseline and after receiving the IO injections. Results: Of the 160 patients included in this study, 80 received IO lignocaine (control group), whereas 80 received IO saline (study group) following randomization. The baseline VAPS score of the patients and controls was 5.71 ± 1.33 and 5.68 ± 1.21, respectively. The difference between the baseline VAPS scores of the two groups was not statistically significant (P > 0.05). The difference between the numbers of patients who experienced pain relief following administration of IO lignocaine (n=74) versus saline (n=69) was not statistically significant (P > 0.05). The difference between VAPS scores measured after IO injection in both groups was not statistically significant (P >0.05) (1.05 ± 1.20 for the control group vs. 1.72 ± 1.56 for the study group) Conclusion: The study demonstrates that IO injection of normal saline is as effective as lignocaine in alleviating pain during surgical removal of impacted mandibular third molars and can be used as an effective adjunct to conventional lignocaine injection.

CLINICAL AND RADIOGRAPHIC STUDY OF DENTIGEROUS CYSTS ACCORDING TO INVOLVED AREA (함치성 낭의 임상적 및 방사선적 특성)

  • Park, Seung-Youn;Nam, Dong-Woo;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.169-179
    • /
    • 2004
  • The purpose of this study was to discriminate clinically and radiographically among the three groups of dentigerous cysts studied. First, Group I, involved area of dentigerous cyst was successive permanent tooth area beneath deciduous tooth. Second, Group II, involved permanent molar area, and the last, Group III involved maxillary anterior supernumerary tooth area. The author observed and compared the clinico-radiographic features of 49 cases of Group I, 36 cases of Group II, and 15 cases of Group III of dentigerous cyst and this observation and comparison had been done by based on the charts and panoramic films. The obtained results were as follows: 1. The cases of Group I were 29 cases and, those of Group II were 36 and those of Group III were 15. 2. The incidence of dentigerous cyst is high in first decade. In Group I, before first decade and early first decade was 87.8%, in Group II and Group III, was discovered more lately. 3. The frequency of dentigerous cyst is 2.5 times higher in male than in female. 4. The sequence of chief complaint was swelling(50%), routine examination(32%), and pain(9%). 5. When considering the type of the cyst, lateral type is many most in Group I (71.4%) and central type is many most in Group II (94.4%) and Group III (100%). 6. The most size of dentigerous cyst was 2 crown size in Group I, 1 crown size in Group II, above of 4 crown size in Group III. 7. Almost involved teeth showed displacement and some tooth of displaced teeth showed delayed root development and dilaceration of root. 8. The most many response of alveolar bone was buccal bone expansion in Group I (67.3%), no bone expansion in Group II(66.7%) and palatal bone expansion in Group III (60.0%). 9. The percentage of involved teeth were as follows : The mandibular third molar was 31% and many most. The mandibular second premolar was 30%. Mesiodens of maxillary anterior area was 15%. The maxillary canine was 8%. The mandibular first premolar was 5%. 10. In the Group I, causes suggesting of dentigeous cyst are pulpotomized deciduous tooth(59.2%), severe dental caries of deciduous tooth, untreated traumatic history on the deciduous tooth etc. 11. The treatment method of dentigerous was marsupialization in 61.2% of cases of Group I and that was enucleation in 61.1% of cases of Group II and in 80.0% of cases of Group III.

  • PDF

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

The pattern of movement and stress distribution during retraction of maxillary incisors using a 3-D finite element method (상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Chung, Ae-Jin;Kim, Un-Su;Lee, Soo-Haeng;Kang, Seong-Soo;Choi, Hee-In;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.98-113
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the displacement pattern and the stress distribution shown on a finite element model 3-D visualization of a dry human skull using CT during the retraction of upper anterior teeth. Methods: Experimental groups were differentiated into 8 groups according to corticotomy, anchorage (buccal: mini implant between the maxillary second premolar and first molar and second premolar reinforced with a mini Implant, palatal: mini implant between the maxillary first molar and second molar and mini implant on the midpalatal suture) and force application point (use of a power arm or not). Results: In cases where anterior teeth were retracted by a conventional T-loop arch wire, the anterior teeth tipped more postero-inferiorly and the posterior teeth moved slightly in a mesial direction. In cases where anterior teeth were retracted with corticotomy, the stress at the anterior bone segment was distributed widely and showed a smaller degree of tipping movement of the anterior teeth, but with a greater amount of displacement. In cases where anterior teeth were retracted from the buccal side with force applied to the mini implant placed between the maxillary second premolar and the first molar to the canine power arm, it showed that a smaller degree of tipping movement was generated than when force was applied to the second premolar reinforced with a mini implant from the canine bracket. In cases where anterior teeth were retracted from the palatal side with force applied to the mini implant on the midpalatal suture, it resulted in a greater degree of tipping movement than when force was applied to the mini implant between the maxillary first and second molars. Conclusion: The results of this study verifies the effects of corticotomies and the effects of controlling orthodontic force vectors during tooth movement.

A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition (상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon;Jung, Sang-Hyuk;Kim, Hui-Jung
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.33-45
    • /
    • 2004
  • The purpose of this experimental study was to determine appropriate magnitude of the Gable bends to produce maximum retraction of the anterior teeth. The Calorific Machine was used to illustrate the tooth movement in three dimension. The experimental teeth except the first premolar were embedded in the artificial alveolar bone part. In a series of experiments, the extraction space was closed using arch wires with bull loops into which the gable bends of $10^{\circ},\;20^{\circ},\;30^{\circ}$ degrees were incorporated. The experiments were repeated three times for each degree of the gable bend. Before and after the space closure, radiographs were taken in the sagittal and occlusal directions using occlusal films. Analysis of variance and Scheffe post hoc test were used to determine significant differences among the three groups. The following results were obtained. 1. As magnitudes of the gable bends increased, more bodily anterior tooth movement was seen and the distance of retraction also increased. 2. As magnitudes of the gable bends increase, the amount of posterior tooth protraction decreased while intrusive and buccal movement increased. 3. The arch was coordinated by distal-in rotation of the canine and mesial-in rotation of the second premolar adjacent to the extraction space.

Histological characteristics of newly formed cementum in surgically created one-wall intrabony defects in a canine model

  • Park, Jung-Chul;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.1
    • /
    • pp.3-10
    • /
    • 2010
  • Purpose: Periodontal regenerative therapies for defects created by severe periodontitis are mainly focused on bone regeneration. Although cementum regeneration needs to be better understood, it is believed to play an important role in periodontal regeneration. The first step toward a full understanding of cementum regeneration is to compare repaired cementum to pristine cementum. This study, which used histological techniques, was designed to focus on cementum regeneration and to compare pristine cementum to repaired cementum after surgical procedures with 8 and 24 week healing periods in a canine model. Methods: Buccal and lingual mucoperiosteal flaps of 10 beagle dogs were surgically reflected to create critical-sized defects. Intrabony one-wall defects, of which dimension is 4 mm width and 5 mm depth, were made at the distal aspect of mandibular second premolars and the mesial aspect of mandibular fourth premolars in the right and left jaw quadrants. Animals were sacrificed after 8 and 24 weeks post-surgery for histological specimen preparation and histometric analysis. Results: The repaired cementum was composed mostly of acellular cementum and cellular mixed fiber cementum and was thicker in the apical area than in the coronal area. The acellular cementum of the supracrestal area appeared to be amorphous. The newly formed cellular cementum was partially detached from the underlying circumpulpal dentin, which implied a weak attachment between new cementum and dentin, and this split was observed to a lesser extent in the 24 week group than in the 8 week group. The vertical height of the repaired cementum was greater in the 24 week group than in the 8 week group. Conclusions: Within the limitations of this study, we can conclude that repaired cementum after root planing was mainly acellular cementum and cementum tissue that matured to a shape similar to pristine cementum as the healing progressed from 8 to 24 weeks.

A FINITE ELEMENT ANALYSIS ON THE 3-UNIT FIXED PROSTHESIS SUPPORTED WITH A NATURAL TOOTH AND ANGLE VARIABLE IMPLANT (고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구)

  • Ko Hyun;Woo Yi-Hyung;Park Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.580-610
    • /
    • 1993
  • The purpose of this study was to analyse the deflection and stress distribution at the supporting bone and it's superstructure by the alteration of angulation between implant and it's implant abutment. For this study, the free-end saddle case of mandibular first and second molar missing would be planned to restore with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder type osseointegrated implant was placed at the site of mandibular second molar for abutment. The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were created, a standard model at $0^{\circ}$ and 12 models created by changing the angulation between implant and implant abutment as increasing the angulation mesially and distally with $5^{\circ}$ unittill $30^{\circ}$. The preprocessing decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and SUN-SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load 1) and distributed load(load 2) at the reference points. The results were as follows : 1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under concentrated load was largest of all, and that at the apex of implant was least of all, and the amount of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all, and that at the apex of implant was least of all. 2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased according to the reference points. But the order according to the amount of total deflection was not changed except apex of second premolar and central fossa of implant abutment under concentrated load during distal inclination. 3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the distal margin of second premolar under distributed load was largest of all, and that at the apex of Implant was least of ail. 4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant were increased under concentrated load and distributed load, but those were increased remarkably under distributed load and so that at $30^{\circ}$ mesial inclination was largest of all. 5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant were increased remarkably under concentrated load and distributed load, and so those at $30^{\circ}$ distal inclination were largest of all.

  • PDF

Efficacy of sonic-powered toothbrushes for plaque removal in patients with peri-implant mucositis

  • Lee, Jungwon;Lim, Jong Heun;Lee, Jungeun;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Ku, Young;Lee, Yong-Moo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.56-61
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the effectiveness of powered toothbrushes for plaque control in patients with peri-implant mucositis, in comparison with manual toothbrushes. Methods: This randomized, prospective, controlled, clinical parallel study compared the efficacy of manual and powered toothbrushes for plaque control in implant restorations. Patients with bleeding on probing, no residual pocket depth (as indicated by a pocket probing depth ${\geq}5mm$), and no radiological peri-implant bone loss were eligible for this study. Patients were requested to complete a questionnaire describing their oral hygiene habits. The duration and frequency of tooth brushing were recorded by subjects in order to assess their compliance. Clinical parameters, including the modified plaque index (mPI), the modified sulcus bleeding index (mSBI), and clinical photographs (buccal and lingual views) were recorded at baseline and at one-month and two-month follow-up visits. Results: Statistically significant differences between patients who used manual toothbrushes and those who used powered toothbrushes were found regarding the frequency of tooth brushing per day and the duration of brushing at one-month and two-month follow-up visits, while no statistically significant differences were found relating to other oral hygiene habits. A statistically significant difference in patient compliance for tooth brushing was found at one month, while no difference was found at two months. Statistically significant decreases in the mPI and the mSBI were observed in both groups from baseline to the one- and two-month follow-ups. The overall reduction of these parameters was not significantly different between the two groups, except for mPI reduction between baseline and one month of follow-up. Conclusions: Sonic-powered toothbrushes may be a useful device for plaque control in patients with peri-implant mucositis.