• Title/Summary/Keyword: Buccal area

Search Result 241, Processing Time 0.024 seconds

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

COMPARISON OF FRACTURE STRENGTH AND PATTERN OF ENDODONTICALLY TREATED TEETH RESTORED WITH FIBER POSTS AND METAL CAST POST (섬유강화 포스트와 금속주조 포스트의 파절강도 밋 파절양상의 비교)

  • Kim Mee-Kyung;Kim Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.535-543
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the effect of two fiber post systems and one metal cast post system on the fracture strength and fracture pattern of crowned, endodontically treated teeth with 2 mm-height of the reamining tooth structure. Materials and methods: A total of 36 recently extracted sound human mandibular premolars were selected Each tooth structure of the crown portion except 2mm-height of the one above the cementoenamel junction was removed. After being endodontically treated, they were randomly distributed into 3 groups: group 1, restored with quarts fiber post(D.T. Light-Post), group 2, with glass fiber post(FRC Postec), and group 3, metal cast post and core. All teeth were fully covered with nonprecious metal crowns. Each specimen was embedded in an acrylic resin block and then secured in a universal load-testing machine. A compressive load was applied at a 130 degree angle to the long axis of the tooth until fractured, at a crosshead speed 20mm/min. The highest fracture loads were measured and recorded as the fracture strength of each specimen. Fracture areas were measured on the mid-buccal and mid-lingual point from the crown margins. One-way analysis of variance and Turkey test were used to determine the statistic significance of the different fracture loads and areas among the groups (p<0.05). Results: The mean fracture loads were $1391{\pm}$425N(group 1), $1458{\pm}476N$(group 2) and $1301{\pm}319N$(group 3). The fracture loads among the three groups had no statistically signifiant difference (p>.05). The mean fracture area of the fiber post was closer to the crown margin than that of the metal cast post and core(p<.05). The metal cast post showed unrestorable and catastrophic fracture patterns. Conclusion: Within the limitations of this study, fracture loads with any statistically significant difference were not recorded for endodontically treated teeth restored with two fiber posts and the metal cast post. But teeth restored with the fiber posts typically showed the fracture pattern close to the crown margin, which was almost restorable.

The validation of Periotest values for the evaluation of orthodontic mini-implants' stability (즉시 부하 교정용 미니임플랜트의 안정성 평가를 위한 Periotest$^{(R)}$의 유효성)

  • Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.167-175
    • /
    • 2010
  • Objective: The aim of this study was to validate the Periotest values for the prediction of orthodontic mini-implants' stability. Methods: Sixty orthodontic mini-implants (7.0 mm $\times$ $\emptyset1.45$ mm; ACR, Biomaterials Korea, Seoul, Korea) were inserted into the buccal alveolar bone of 5 twelve month-old beagle dogs. Insertion torque (IT) and Periotest values (PTV) were measured at the installation procedure, and removal torque (RT) and PTV were recorded after 12 weeks of orthodontic loading. To correlate PTV with variables, the cortical bone thickness (mm) and bone mineral density (BMD) within the cortical bone and total bone area were calculated with the help of CT scanning. Results: The BMD and cortical bone thickness in mandibular alveolus were significantly higher than those of the maxilla (p < 0.05). The PTV values ranged from -3.2 to 4.8 for 12 weeks of loading showing clinically stable mini-implants. PTV at insertion was significantly correlated with IT (-0.51), bone density (-0.48), cortical bone thickness (-0.42) (p < 0.05) in the mandible, but showed no correlation in the maxilla. PTV before removal was significantly correlated with RT (-0.66) (p < 0.01) in the mandible. Conclusions: These results show that the periotest is a useful method for the evaluation of mini-implant stability, but it can only be applied to limited areas with thick cortical and high density bone such as the mandible.

FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE (재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석)

  • Kim, Su-Gwan;Kim, Jae-Duk;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

A CLINICAL AND RADIOLOGICAL STUDY ON THE EFFECT OF SYNTHETIC BONE IN CLASS II AND III FURACATION INVOLVEMENTS (2급 및 3급 치근이개부 병변에서 합성골이식의 효과에 대한 임상적 및 방사선학적 연구)

  • Yum, Kyu-Sun;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.475-492
    • /
    • 1993
  • The effect of synthetic bone materials was assessed in the patients with pure periodontal class II and III furcation defects. The buccal aspects of the maxillary and mandilular first and second molars were surgically exposed, and synthetic bone materials were interposed between the gingival flap and the furcation defects in the experimental group. The control group were treated without the use of synthetic bone materials by same operator. Probing pocket depth, gingival recession, and loss of attachment, were measured by Michigan O-probe and tooth mobility was evaluated by an electronic mobility tester(Periotest(R), Siemens co. Germany) at preoperation and 3-, 6-, and 12-month postoperation. Standardized radiogrphs were taken at preoperation and 6-month and 12-month postoperation. The postoperative change of clinical parameters and the difference between experimental group and control group were statistically analyzed by Student, t-test. The results were as follows: 1. The probing pocket depth at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at preoperative examination in both experimental group and control group(P<0.005), but there was no significantly difference between experimental group and control group. 2. The amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was increased, compared to that at the preoperative examination in both experimental and control group(P<0.005). In the case of the class III furcation involvement, the amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was more significantly increased in control group than experimental group(P<0.05). 3. The amount of loss of attachment at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group in the case of class II furcation involvement, and in experimental group only in the case of furcation III involvement(P<0.005). The amount of loss of attachment at, the 3-, 6-, and 12-month postoperative examination was more significantly decreased in experimental group than control group in the case of the class III furcation involvement(P<0.05), but in the case of class II furcation involvement there was no significant difference between experimental group and control group. 4. The tooth mobility at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group(P<0.005), but there was no significant difference between experimental group and control group. 5. Radiopacity of furcation area was greatly increased in the experiment group, but there was no radiographic change in the control group.

  • PDF

THREE-DIMENSIONAL EVALUATION OF IMPACTED MAXILLARY CANINES USING CONE BEAM COMPUTED TOMOGRAPHY AND PANORAMIC RADIOGRAPHS (Cone beam CT와 파노라마방사선사진을 이용한 매복 상악 견치의 3차원적 분석)

  • Jeon, Sang-Yun;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.2
    • /
    • pp.106-117
    • /
    • 2013
  • Normal eruption of the canine is important for the transition to the permanent dentition. Etiologies, including premature loss or delayed retention of deciduous teeth, neoplasm and abnormality of lateral incisor can cause impaction of the maxillary canine. Untreated canine impaction can result in malocclusion, cyst formation and obstacles in orthodontic treatment. The aim of this study is to evaluate location of the impacted maxillary canine and to identify correlation between location and management of the impaction including complications. Using panoramic radiographs and CBCT scan, images of 89 children diagnosed with impaction of the maxillary canine, location of impacted canines was evaluated. The choice of treatment and complications were investigated to identify correlation. Results show that the most commonly impacted location of the maxillary canine was in the mid-alveolar area, followed by buccal side and palatal side. Orthodontic traction was selected more frequently than the other treatments. As complications, displacement of adjacent tooth was occurred most frequently. Buccally impacted canines showed increased tendency towards displacement. The more buccally the canine was impacted, the less orthodontic traction was chosen as the treatment. The canine impacted mesially to the central incisor showed increased tendency to occur root resorption. Therefore, early diagnosis by periodic examination, appropriate treatment and intervention is required.

Reconstruction with Radial Forearm Free Flap after Ablative Surgery for Oral Cavity and Oropharyngeal Cancers (구강암과 구인두암의 절제술 후 전완유리피판술을 이용한 재건술)

  • Cho Kwang-Jae;Chun Byung-Jun;Sun Dong-Il;Cho Seung-Ho;Kim Mn-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.41-46
    • /
    • 2003
  • Background and Objectives: Surgical ablation of tumors in the oral cavity and the oropharynx results in a three dimensional defect because of the needs to resect the adjacent area for the surgical margin. Although a variety of techniques are available, radial forearm free flap has been known as an effective method for this defect, which offers a thin, pliable, and relatively hairless skin and a long vascular pedicle. We report the clinical results of our 54 consecutive radial forearm free flaps used for oral cavity and oropharynx cancers. Materials and Methods: We reviewed the medical records of patients who were offered intraoral reconstruction with a radial forearm free flap after ablative surgery for oral cavity and oropharyngeal cancers from August 1994 to February 2003 and analyzed surgical methods, flap survival rate, complication, and functional results. Among these, 20 cases were examined with modified barium swallow to evaluate postoperative swallowing function and other 8 cases with articulation and resonance test for speech. We examined recovery of sensation with two-point discrimination test in 15 cases who were offered sensate flaps. Results: The primary sites were as follows : mobile tongue (18), tonsil (17), floor of mouth (4), base of tongue (2), soft palate (2), retromolar trigone (3), buccal mucosa (1), oro-hypopharynx (6), and lower lip (1). The paddles of flaps were tailored in multilobed designs from oval shape to tetralobed design and in variable size according to the defects after ablation. This procedures resulted in satisfactory flap success rate (96.3%) and showed good swallowing function and social speech. Eight of 15 cases (53.3%) who had offered sensate flap showed recovery of sensation between 1 and 6 postoperative months (average 2.6 month). Conclusion: The reconstruction with radial forearm free flap might be an excellent method for the maximal functional results after ablative surgery of oral cavity and oropharyngeal cancers that results in multidimensional defect.

Complete denture made with closed-mouth impression technique on severely atrophied edentulous jaw (하악 치조골이 심하게 위축된 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Lee, Suk-Hwan;Leesungbok, Richard;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.195-202
    • /
    • 2019
  • At the department of prosthodontics, the elderly patients with severely atrophied alveolar ridge who have been wearing complete dentures for a long period frequently visit the clinic. In general, the open-mouth impression technique for manufacturing a mandibular complete denture to secure primary support on buccal shelf area has been prevalent. In addition, for securing retention and stability of mandibular denture, we should consider diagnosis, oral function, denture border, occlusal plane, teeth arrangement, and patient training, etc.. But in edentulous patients with severe alveolar bone atrophy, it may hardly secure retention and stability of mandibular complete denture. To promote these, some of clinicians are making an attempt manufacturing the mandibular complete dentures using closed-mouth impression technique based on several reports that compare various impression techniques including open-mouth and closed-mouth impression technique. This case report suggests closed-mouth impression technique may promote retention and stability of mandibular complete denture and compares between the two impression techniques clinically.

Factors Influencing the Duration of Forced Eruption in Impacted Maxillary Canines (상악 매복 견치의 견인 기간에 영향을 미치는 요인에 대한 분석)

  • Ji-hye, Han;Yon-joo, Mah
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.402-413
    • /
    • 2022
  • The aim of this study was to identify factors that affect the treatment duration and to predict the duration of forced eruption in impacted maxillary canines using panoramic radiographs and cone-beam computed tomography. This retrospective study was performed by reviewing medical records and radiographs of 73 patients (93 impacted maxillary canines) from the age of 8 to 18 years who were treated with surgical and orthodontic interventions on impacted maxillary canines from January 2012 to December 2020 in Ajou University Dental Hospital. Stepwise multiple regression analysis showed that the distance between the canine cusp tip and the occlusal plane, mesio-distal location, bucco-palatal location, patient's age, and use of rapid palatal expansion are significant factors with regard to the duration of forced eruption. There was a statistically significant correlation of the treatment duration with the angulation between the axis of the canine and the occlusal plane and unilateral or bilateral impaction. It can be concluded that the duration of forced eruption in impacted maxillary canines could be shorter when the impacted canine is closer to the occlusal plane and located in the lateral incisor or canine area, buccal or middle, the patient is younger and uses rapid palatal expansion.

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.