• Title/Summary/Keyword: Bronchoscopes

Search Result 5, Processing Time 0.022 seconds

Airway obstruction by dissection of the inner layer of a reinforced endotracheal tube in a patient with Ludwig's angina: A case report

  • Shim, Sung-Min;Park, Jae-Ho;Hyun, Dong-Min;Lee, Hwa-Mi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.2
    • /
    • pp.135-138
    • /
    • 2017
  • Intraoperative airway obstruction is perplexing to anesthesiologists because the patient may fall into danger rapidly. A 74-year-old woman underwent an emergency incision and drainage for a deep neck infection of dental origin. She was orally intubated with a 6. 0 mm internal diameter reinforced endotracheal tube by video laryngoscope using volatile induction and maintenance anesthesia (VIMA) with sevoflurane, fentanyl ($100{\mu}g$), and succinylcholine (75 mg). During surgery, peak inspiratory pressure increased from 22 to $38cmH_2O$ and plateau pressure increased from 20 to $28cmH_2O$. We maintained anesthesia because we were unable to access the airway, which was covered with surgical drapes, and tidal volume was delivered. At the end of surgery, we found a longitudinal fold inside the tube with a fiberoptic bronchoscope. The patient was reintubated with another tube and ventilation immediately improved. We recognized that the tube was obstructed due to dissection of the inner layer.

Fistula Formation between Right Upper Bronchus and Bronchus Intermedius Caused by Endobronchial Tuberculosis: A Case Report

  • Kim, Mikyoung;Kang, Eun Seok;Park, Jin Yong;Kang, Hwa Rim;Kim, Jee Hyun;Chang, YouJin;Choi, Kang Hyeon;Lee, Ki Man;Kim, Yook;An, Jin Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.3
    • /
    • pp.286-288
    • /
    • 2015
  • Endobronchial tuberculosis is defined as a tuberculous infection of the tracheobronchial tree and has a prevalence of up to 50% in active pulmonary tuberculosis cases. The most common complication of endobronchial tuberculosis is bronchial stenosis; benign fistula formation by endobronchial tuberculosis is rare, especially inter-bronchial fistula formation. We reported a rare case of a 73-year-old woman with a fistula between the right upper bronchus and bronchus intermedius. A diagnosis of inter-bronchial fistula caused by endobronchial tuberculosis was based on the results of chest computed tomography scans, bronchoscopy, and microbiological and pathological tests. The patient was treated with anti-tuberculous medication, and her symptoms gradually improved.

The Effects of Bronchoscope Diameter on the Diagnostic Yield of Transbronchial Lung Biopsy of Peripheral Pulmonary Nodules

  • Lee, Nakwon;Kim, Sang-Ha;Kwon, Woocheol;Lee, Myoung Kyu;Yong, Suk Joong;Shin, Kye Chul;Jung, Ye-Ryung;Choi, Yeun Seoung;Choi, Jiwon;Choi, Ji Sun;Lee, Won Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.77 no.6
    • /
    • pp.251-257
    • /
    • 2014
  • Background: Transbronchial lung biopsy (TBLB) is a valuable diagnostic tool for peripheral pulmonary lesions. The diagnostic yield of TBLB reportedly ranges from 41%-60%. Many studies demonstrated the various factors that influence the yield of TBLB, including size, location, and distance from the carina or pleura. However, no study has evaluated the effects of the bronchoscope diameter. We evaluated whether the bronchoscope diameter affected the diagnostic yield of TBLB. Methods: We reviewed records from 178 patients who underwent TBLB using bronchoscopes of two different diameters (5.7 mm, thick outer diameter, Olympus BF-200; 4.9 mm, thin, BF-260). The fluoroscopic guidance rates, yield of TBLB and flexible bronchoscopy (FB) were compared between the two groups. Additionally, we compared the results of the procedures with respect to diagnosis, distance from the pleura, and size of the lesion. Results: The results of fluoroscopic guidance, TBLB, and FB yield using thin diameter bronchoscope were significantly better than those obtained with a thick diameter bronchoscope (p=0.021, p=0.036, and p=0.010, respectively). Particularly, when the distance from the pleura was ${\leq}10mm$, success rates for fluoroscopic guidance and FB with thin bronchoscope were higher (p=0.013 and p=0.033, respectively), as compared to with thick bronchoscope. Conclusion: A thinner diameter bronchoscope increased the yield of bronchoscopy, and bronchial washing in conjunction with TBLB was useful in the diagnosis of peripheral pulmonary nodules.

Pseudoepidemic of Mycobacteria Other Than Tuberculosis (MOTT) Due to Contaminated Bronchoscope (기관지경 오염에 의한 비결핵항산균증의 위발생)

  • Kwak, Seung-Min;Kim, Se-Kyu;Jang, Joong-Hyun;Lee, Hong-Lyeol;Lee, Yi-Hyung;Kim, Sung-Kyu;Lee, Won-Young;Jeong, Yoon-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.29-34
    • /
    • 1993
  • Background: The development of the flexible fiberoptic broncoscope by Ikeda was an important technologic advance in the diagnosis and management of patients with pulmonary disease. But, cross contamination related to fiberoptic bronchoscope was reported in cases involving tubercle bacilli, MOTT and other agents. Therefore, cleaning and disinfecting of fiberoptic bronchoscope requires careful attention. Methods: From September 1991 to May 1992, medical records of all patients with positive culture for MOTT in bronchial washing specimens were reviewed. Also to evaluate bactericidal effect of 2% glutaraldehyde, culture was performed after inoculum of MOTT, Serratia marsescens and Pseudomonas aeruginosa to the disinfectant solution. Results: In 2% alkaline glutaraldehyde, MOTT was not survived only after 30 minute exposure, but P. aeruginosa and S. marsescens were rapidly inactivated with no survivors after exposure to 2% glutaraldehyde. Since vigorous mechanical cleansing and more than 30 minute of contact time within washing machine, no more outbreak was observed. Conclusions: It is also very important that bronchoscopes must be meticulously cleaned after each procedure and more than 30 minute exposure would be required for eradication of MOTT with 2% glutaraldehyde. However even the most strictly applied infection control measures cannot exclude contamination completly and clinicians have to stay alert to this possibility. Prompt detection of pseudoepidemics is possible if abrupt increase in isolation rates, especially if they involve unusual or generally nonpathogenic organisms, are readily recognized.

  • PDF

Physiologic Changes During Bronchoscopy in Mechanically Ventilated Patients (기계환기중인 환자에서 기관지내시경 검사에 따른 생리적 변화)

  • Pyun, Yu Jang;Suh, Gee Young;Koh, Won-Jung;Yu, Chang-Min;Jeon, Kyeongman;Jeon, Ik Soo;Ham, Hyoung Suk;Kang, Eun Hae;Chung, Man Pyo;Kim, Hojoong;Kown, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.5
    • /
    • pp.523-531
    • /
    • 2004
  • Background : Bronchoscopy in patients on mechanical ventilation is being performed much more frequently. However, there is little data on the changes in physiologic parameters and no established mechanical ventilation protocol during bronchoscopy. A decreasing or the removal of positive end-expiratory pressure (PEEP) during bronchoscopy may precipitate severe hypoxemia and/or derecruitment. Methods : Our standardized mechanical ventilation protocol, without changing the PEEP level, was used during bronchoscopy. The physiological parameters were measured during the bronchoscopic procedure. Results : During bronchoscopy, respiratory acidosis, elevation of peak pressure, elevation of heart rate and auto-PEEP were developed, but were reversible changes. Procedure-related gross barotraumas or other severe complications did not developed. Conclusion : No serious complications developed during bronchoscopy under our standardized mechanical ventilation protocol when the PEEP level remained unchanged. The procedure time should be kept to a minimum to decrease the exposure time to undesirable physiological changes.