• Title/Summary/Keyword: Broken Wire

Search Result 34, Processing Time 0.034 seconds

The Design of a I/O Interface Circuits for the Signal Driver of the Engine Control Relays and the Output Signal Monitoring of Diesel Generator (디젤 발전기 출력 신호의 모니터링 및 엔진제어 릴레이 구동을 위한 입출력 인터페이스 회로 설계)

  • Joo, Jae-hun;Kim, Jin-ae;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.547-550
    • /
    • 2009
  • This paper presents a digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for Emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes pick-up coil signal.

  • PDF

Physical and Mechanical Properties of PP Fiber Reinforced Concrete for Binder Course in Landscape Paving (조경용 포장 중간층에 사용가능한 PP섬유 보강 콘크리트의 물리·역학적 특성연구)

  • Jun, Hyung-Soon;Lee, Jae-Keun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.1
    • /
    • pp.17-25
    • /
    • 2013
  • The mechanical properties appeared at the concrete mixed with Polypropylene fiber($1kg/m^3$, $3kg/m^3$, $5kg/m^3$) are compared with normal concrete and wire mesh one and evaluated. Achieved slump test to search effect that PP fiber gets to workability, even if the mixing amount of fiber increases, confirmed that slump value is no change almost. The no difference can be caused by hard mixture, but because of the big softness of fiber there is no effect greatly up to PP fiber mixing amount $5kg/m^3$ even with soft mixture. Compressive strengths and flexural strengths of the concretes with PP fiber and without the fiber are appeared almost alike. If examine load resistance ability by PP fiber mixing amount increase, it could know that the increase of fiber mixing amount improves load resistance ability and the toughness index is increased. While normal concrete is broken at the same time with crack, fiber mixed concrete stand in flexure load continuously after crack occurrence. In compare with wire mesh embeded concrete, wire mesh mixed concrete stands in some degree in flexure load by wire mesh crack occurrence and the test piece was broken at the same time. But, it could know that the PP fiber mixed concrete resist continuously to flexure load in bigger displacement.

Methodology of Parallel Ground Conductor Installation on Underground Transmission System (지중송전 시스템의 병행지선 설치 방안 연구)

  • Hong, Dong-Suk;Park, Sung-Min;Hahn, Kwayng-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.470-471
    • /
    • 2008
  • SVL is installed at underground transmission system to protect cables and insulation joint-box from overvoltages caused by lightning, switching, and line-to-ground fault. Domestic underground power system adopts cross bonding type to reduce the induced voltage at sheath, but single-point bonding is required depending the system installation configuration. SVL can be easily broken by overvoltages induced at joint-box because single-point bonding has uneffective system structure to extract fault current. ANSI/IEEE recommends Parallel Ground Continuity Conductor(PGCC) to prevent SVL breakdown. In this paper, EMTP simulation is performed to analyze effects on SVL under PGCC installation when single-line-to-ground fault occurs. The result shows that PGCC and short single-point bonding distance can reduce overvoltages at SVL.

  • PDF

A Study on Crane Wire Rope Flaws Signal Processing Using Discrete Wavelet Transform (Wavelet 변환을 이용한 크레인 와이어 로프 결함 신호처리에 관한 연구)

  • Min, Jeong-Tak;Sohn, Dong-Seop;Lee, Jin-Woo;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.155-159
    • /
    • 2002
  • Wire ropes are used in a myriad of various industrial applications such as elevator, mine hoist, construction machinery, lift, and suspension bridge. Especially, wire rope of crane is important component to container transfer. If it happens wire rope failures in operating, it may lead to safety accident, economic power loss by productivity decline, competitive power decline of container terminal and so on. To solve this problem, we developed wire rope fault detecting system as a portable instrument, and this system is consisted of 3 parts that fault detecting part using hall sensor, permanent magnets and analog unit, and digital signal processing part using data acquisition card, monitoring part using wavelet transform, denoising method. In this paper, a wire rope is scanned by this system after makes several broken parts on the surface of wire rope artificially. All detected signal has external noise or disturbance according to circumstances. So, we applied to discrete wavelet transform to extract a signal from noisy data that was used filter. In practical applications of denoising, it is shown that wavelet pursue it with little information loss and smooth signal display. It is verified that the detecting system by denoising has good efficiency for inspecting faults of wire ropes in service. As a result, by developing this system, container terminal could reduce expense because of extension of wire ropes exchange period and could competitive power. Also, this system is possible to apply in several fields like that elevator, lift and so on.

  • PDF

Development of Nondestructive Detecting System for Elevator Wire Ropes using Hall-effect Sensors (Hall 센서를 이용한 엘리베이터 와이어 로프의 비파괴 검출시스템의 개발)

  • Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.33-41
    • /
    • 2001
  • Wire ropes have been widely used in industrial applications, wherever heavy weight should be carried safely or mechanical energy should be transmitted fast. Especially, wire rope failures in operating elevator may lead to extensive property damage and serious injury to nearby personnel. Hence, it is very important to inspect wire rope periodically. Failure defection of wire rope requires fundamental knowledge of wire rope construction, rope behavior, properties of fault, sensing and signal processing method. In this research, the development of a new fault detecting system incorporating Hall-effect sensors to detect flaws such as abrasion, broken wire, corrosion and deformation for aged wire ropes in elevator, is described. For using a detector as a portable instrument, several performances for implementing sensing part with Hall-effect sensor, analog signal processing unit and programs are described. Experiments and field testing results for the implemented detecting system are also given. As a result, it is verified that the detecting system has good efficiency for inspecting faults of aged wire ropes in service.

  • PDF

Migration of K-wires from the Acromioclavicular Joint to the Neck - Case Report(2 cases) - (견봉 쇄골 관절 탈구에 사용된 K-강선의 경추부로의 이동 - 증례보고(2예) -)

  • Lee, Woo-Seung;Kim, Taik-Seon;Yoon, Jeong-Ro;Kim, Young-Bae;Seo, Dong-Hoon;Kwon, Jae-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.196-201
    • /
    • 2006
  • We report two cases of migration of K-wires from the acromioclavicular joint to the neck. A 73-year-old man complained of right shoulder pain for one month and had undergone orthopedic surgery because of acromioclavicular joint dislocation about 27 years earlier. Another 56-year-old man complained of left shoulder pain and neck pain for 5 years and had undergone orthopedic surgery because of acromioclavicular joint dislocation about 25 years earlier. In both cases, we took X-rays to look for the cause of shoulder pain and discovered broken and migrated K-wires in the neck. We removed the K-wires from the trapezius muscle and the paraspinal muscle respectively. K-wire fixation technique is simple and effective but should be followed up with X-rays periodically. In addition, we should warn patients of the possibility of migration of K-wire. And it is desirable for us to avoid using K-wire near major neurovascular structures like the sternoclavicular joint and the clavicle.

Considerations in the reliability improvement against Circulation Current in the Catenary System for Electirc Railway of Korea (전차선로시스템의 순환전류에 대한 안정성 향상에 관한 고찰)

  • Kim, In-Cheol;Kang, Seung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.24-26
    • /
    • 2006
  • In these days, Korea Railway apply simple catenary system to general lines and high speed lines of Korea Electric Railway. Circulation Current in catenary system frequently bring undesirable consequences. Namely, the Connector wire has many problems according to a flow of excessive circulation (or traction current) and a sudden rise of temperature on catenary when electric car or locomotive is running in high speed. The occurrence of events by the load increasement do considerable damages to peoples, organizations and systems. In this paper, we proposed the improved changes on the catenary system of a improvement and change of a messenger wire protector, improvement of connector wire,s institution angle and of a replacement the connector wire with a dropper. A case of Circulation Current continually has broken out in Yongdungpo Electric Office's own bailiwick. By or through the medium of these obstacles, we have further use of many studies and considering countermeasures. Therefore, we have to deal with the question in design and execution of catenary system for High Speed Railway because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

Back Fed Earth Fault Detection in Three Wire-Unigrounded Distribution-System By Zero Sequence Admittance (영상어드미턴스에 의한 직접접지 배전방식에서의 역가압 지락사고 검출)

  • Yoo, Myeong-Ho;Kim, Il-Dong;Han, Hong-Seok;Pak, Chul-Won
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.120-123
    • /
    • 1993
  • This paper presents the developing a new algorithm for detecting the Back fed Earth Fault in three wire-unigrounded distribution system by zero sequence admittance. So called "Backfed Earth Fault" of the electric power distribution line refers to a class of earth faults that the load-side line only is grounded, following after the distribution line broken into two parts, the source-side and the load-side. Because its mechanism differs from that of other earth faults, it is therefore, required to examine. This paper deals with the detailed software of the digital protective relay for Backfed earth fault. In order to prove that the proposed schemes is good, we performed off-line simulation using data from EMTP and ETSA(Electrcity Trust Of South Austrilia). It is shown that the suggested algorithm is never mal operated.

  • PDF

Migration of Early Broken Wire into the Popliteal Fossa through Popliteal Hiatus in Internally fixed Fracture of Patella - A Case Report - (내고정한 슬개골 골절에서 슬와공을 통한 조기 파절된 강선 조각의 슬와부로의 이동 - 증례보고 -)

  • Jeon, Ho-Seung;Jeon, Seung-Ju;Moon, Chan-Sam;Noh, Hang-Gi;Jeong, Hyung-Jun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.170-173
    • /
    • 2009
  • Wiring techniques in the fixation of patellar fracture are commonly used. Rigid fixation is essential for early rehabilitation. Breakages of wires after the fixation of patellar fracture are common with extracapsular migration if not removed for long term. But, we experienced a case of patellar fracture with early breakage of wiring and migration of the broken wire fragment into the popliteal fossa through the popliteal hiatus in 64- year-old man and we successfully treated this case, using both arthroscopic and open procedures. So we report this unusual case with a review of current literatures.

  • PDF

Development of Automated Electric Snowplow by Using Clutch Bobbin for Improving Durability (내구성 향상을 위한 클러치 보빈 적용 고강성 전동식 제설기 개발)

  • Kim, Kee Joo;Park, Jun-Hyub
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.949-954
    • /
    • 2016
  • When a snowplow is operating in the up or down direction, the sensor stops the movement automatically and the wire could be broken from an endless drive in the reverse direction impact or conversely winding wire. In the present study, a new bobbin was designed to ensure the durability of snowplows; in this design, the bobbin plays the role of a clutch during power transfer or idling. This will protect the blade of the snowplow during an impact and maintain close contact of the blade with the road. Therefore, the new technology to eliminate the tension and fatigue of the wire is suggested by winding a chain instead of the wire in the newly designed bobbin. From these, it was developed to extend the life of the snowplow without causing damages to the vehicle.