• Title/Summary/Keyword: Brightness uniformity

Search Result 101, Processing Time 0.021 seconds

Design and Evaluation of LCD Backlight Unit by LED Array Modules

  • Aung, Aye Thida;Lee, Seung-Min;Yang, Jong-Kyung;Park, Dae-Hee;Lee, Seong-Jin;Lee, Jong-Chan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.110-115
    • /
    • 2008
  • In this paper, we have designated a 42-inch RGB LED BLU, 80 % above illuminance. A desirable brightness performance was attained, by doing anti-parallel configuration, a fitting of LED's strip distance and a height of the top of LED to the back of the LCD. We get the 85.81 % of the brightness uniformity which has 12.8 mm away from LED's top and LCD's back and 51.41 mm of the same spacing between LED's strip in simulation and 82.24 % in experiment.

Flat Fluorescent Lamp(EEL) and LCD TV Backlight Using EEL as a Light Source (면광원 램프 및 이를 이용한 LCD TV용 백라이트)

  • Park, Jong-Lee;Kim, Chung-Soo;Lim, Sung-Kyoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.2 s.43
    • /
    • pp.1-8
    • /
    • 2007
  • A flat fluorescent lamp (FFL) was developed as a light source for LCD TV Backlight. The channels of FFL were realized by forming the flat glass at high temperature. The performance of the backlight with FFL was shown to improve by optimizing the FFL channel profile that has elliptical shape, 4.4 mm height and 1.4 mm sealing distance. In this paper, the brightness uniformity of LCD TV backlights was investigated by optical simulation of FFL channel profiles. The brightness of LCD TV using FFL with the optimized channel profile was shown to be $576\;cd/m^2$.

  • PDF

Brightness uniformity measurement analysis of the medical clinical monitoring (의료용 임상 모니터의 휘도 균일성 측정 방법 분석)

  • Kim, Seon-chil;Baek, Su-min;Lee, Jun-seok
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.57-60
    • /
    • 2015
  • 병원에서 사용되는 임상용 모니터의 관리는 중요하다. 모니터의 기본적 관리는 휘도이며, 휘도에서도 균일도가 가장 먼저 관리되는 대상이다. 특히 LCD 모니터인 경우 균일도에 문제가 모니터의 교체주기와 일치하는 경우가 많다. 휘도에 대한 평가는 여러 가지가 존재하지만, 본 연구에서는 AAPM TG18에 따라 TG18-UNL10, TG18-UNL80을 이용하여 휘도의 균일도를 조사하였다. 이 조사과정에서 측정값 중 가장 높은 수치를 기준으로 나머지 값의 편차를 구하는 방법과 평균값을 이용하여 측정값의 편차를 구하는 방법 두 가지를 사용하였으며, 두 가지 방법의 유의성을 알아보고자 휘도의 편차 변화량 즉, 균일도를 측정하였다. 휘도 균일도의 정량평가는 향후 모니터의 관리에 가장 큰 영향을 미치는 인자로써 측정기간 중 변화량은 매우 적게 나타났다. 따라서 본 연구에서 제시된 최대, 최소값의 편차나 평균값의 상대 편차값 모두 유의한 결과를 얻을 수 있었다.

  • PDF

Fabrication and Characterization of Film Type Light Guide Plates by UV Imprint Lithography (UV 임프린팅법에 의한 필름형 광도광판의 제조 및 특성 연구)

  • Kim, Hyeong-Gwan;Kim, So-Won;Lee, Hee-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.2
    • /
    • pp.178-185
    • /
    • 2016
  • In this study, we have fabricated light guide plates (LGPs) in thin film form for edge type back light unit (BLU) by using UV imprint lithography. In the LGPs, the pattern of functional resins on PC and PMMA substrates were successfully transferred from original master mold through PVC stamp. Optimized pattern arrays with slowly-sloped density were designed to obtain high brightness and uniformity. We could obtain a relatively improved brightness of $950cd/m^2$ and a uniformity of 87.3% by using the NP-S20 functional resins at an input power of 1.3 W because NP-S20 resin could show high formability after UV hardening process. The LGP prepared on polymethylmethacrylate (PMMA) substrate exhibited higher brightness than that on polycarbonate (PC) substrate because PMMA has lower refractive index resulting in more refraction toward the vertical direction.

An Improved Texture Feature Extraction Method for Recognizing Emphysema in CT Images

  • Peng, Shao-Hu;Nam, Hyun-Do
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.11
    • /
    • pp.30-41
    • /
    • 2010
  • In this study we propose a new texture feature extraction method based on an estimation of the brightness and structural uniformity of CT images representing the important characteristics for emphysema recognition. The Center-Symmetric Local Binary Pattern (CS-LBP) is first used to combine gray level in order to describe the brightness uniformity characteristics of the CT image. Then the gradient orientation difference is proposed to generate another CS-LBP code combining with gray level to represent the structural uniformity characteristics of the CT image. The usage of the gray level, CS-LBP and gradient orientation differences enables the proposed method to extract rich and distinctive information from the CT images in multiple directions. Experimental results showed that the performance of the proposed method is more stable with respect to sensitivity and specificity when compared with the SGLDM, GLRLM and GLDM. The proposed method outperformed these three conventional methods (SGLDM, GLRLM, and GLDM) 7.85[%], 22.87[%], and 16.67[%] respectively, according to the diagnosis of average accuracy, demonstrated by the Receiver Operating Characteristic (ROC) curves.

Design of White Balance Correction Processor for High Resolution Full Color LED Display System (고해상도 천연색 LED 디스플레이 시스템을 위한 흰색 보정프로세서의 설계)

  • Lee, Jong-Ha;Ko, Duck-Young
    • 전자공학회논문지 IE
    • /
    • v.46 no.3
    • /
    • pp.12-18
    • /
    • 2009
  • In this paper, we developed white balance correction processor for Full Color LED Display System which could be display uniformity color and soft light by adjusting brightness of red, green, blue pixel, individually. This processor correct brightness by calculating operating current of each pixel(red, green, blue LED) on the basis of characteristic curve of LED device when we named "a" as a specific characteristic value, "b" as a brightness correction value according to using time, "X" as a operating current value, and "Y" as brightness value. As the results, we solved the reduction problem of brightness for long used LED devices, according to increase entire mean of brightness value by adjusting "b" value from the brightness characteristic function.

Adaptive Multi-threshold Based Mura Detection on A LCD Panel (적응적 임계화법에 기반한 LCD 얼룩 검사)

  • 류재승;곽동민;박길흠
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.347-350
    • /
    • 2003
  • In this paper, a new automated defects detection method for a TFT-LCD panel is presented. An input image is preprocessed to lessen small abnormal noises and non-uniformity of the image. The adaptive multi-thresholds are used to detect Muras, which are the major defects occurred on TFT-LCD panels. Those are determined adaptively depending on the brightness and the brightness distribution of a local block. For the synthetic images and real Mura images, the proposed algorithm can effectively detect Muras in a reasonable time.

  • PDF

High Brightness Prism Light-guide Plate for TFT-LCDs Using Optical Simulation and Novel Injection Mold Process (광학시뮬레이션과 새로운 사출성형법을 사용한 TFT-LCD용 고휘도 프리즘 도광판)

  • Han, Jeong-Min;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.2
    • /
    • pp.93-96
    • /
    • 2012
  • We have designed high performance prism light-guide plate (LGP) in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8mm adding prism construct. Using optical simulation, we forecast the brightness and uniformity in LGP with prism structure. And we adopted novel injection mold method and Nickel stamper to make actual evolution sample. Novel injection mold process has steady heating time zone in heat cycle time of injection mold process. For this novel heat cycle control, we achieved above 90[%] height prism structure as our design. It is superior brightness improvement than previous that of printing form about some 20[%] and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

Xe-free 8" class flat fluorescent lamp with good uniformity (8"평판형광램프에 관한 연구)

  • Park, S.G.;Kim, S.Y.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.568-569
    • /
    • 2000
  • By manufacturing 8" class $146{\times}96mm$ "flat fluorescent lamp" of new form that uses xenon gas, an electric optical characteristic has been analyzed. Lamp shows that the lamp surface brightness is 4900 cd/m2 and the birghtness uniformity degree is 90% under sine wave of 15khz and applied voltage of 1,000 Vrms.

  • PDF