• Title/Summary/Keyword: Bright Noise

Search Result 48, Processing Time 0.021 seconds

Comparison of Model Fitting & Least Square Estimator for Detecting Mura (Mura 검출을 위한 Model Fitting 및 Least Square Estimator의 비교)

  • Oh, Chang-Hwan;Joo, Hyo-Nam;Rew, Keun-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.5
    • /
    • pp.415-419
    • /
    • 2008
  • Detecting and correcting defects on LCD glasses early in the manufacturing process becomes important for panel makers to reduce the manufacturing costs and to improve productivity. Many attempts have been made and were successfully applied to detect and identify simple defects such as scratches, dents, and foreign objects on glasses. However, it is still difficult to robustly detect low-contrast defect region, called Mura or blemish area on glasses. Typically, these defect areas are roughly defined as relatively large, several millimeters of diameter, and relatively dark and/or bright region of low Signal-to-Noise Ratio (SNR) against background of low-frequency signal. The aim of this article is to present a robust algorithm to segment these blemish defects. Early 90's, a highly robust estimator, known as the Model-Fitting (MF) estimator was developed by X. Zhuang et. al. and have been successfully used in many computer vision application. Compared to the conventional Least-Square (LS) estimator the MF estimator can successfully estimate model parameters from a dataset of contaminated Gaussian mixture. Such a noise model is defined as a regular white Gaussian noise model with probability $1-\varepsilon$ plus an outlier process with probability $varepsilon$. In the sense of robust estimation, the blemish defect in images can be considered as being a group of outliers in the process of estimating image background model parameters. The algorithm developed in this paper uses a modified MF estimator to robustly estimate the background model and as a by-product to segment the blemish defects, the outliers.

The long-term centimeter variability of active galactic nuclei: A new relation between variability timescale and black hole mass

  • Park, Jongho;Trippe, Sascha
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.36.2-37
    • /
    • 2016
  • We study the long-term radio variability of 43 radio bright AGNs by exploiting the data base of the University of Michigan Radio Astronomy Observatory (UMRAO) monitoring program. The UMRAO database provides high quality lightcurves spanning 25 - 32 years in time at three observing frequencies, 4.8, 8, and 14.5 GHz. We model the periodograms (temporal power spectra) of the observed lightcurves as simple power-law noise (red noise, spectral power $P(f){\propto}f^{-{\beta}}$ using Monte Carlo simulations, taking into account windowing effects (red-noise leak, aliasing). The power spectra of 39 (out of 43) sources are in good agreement with the models, yielding a range in power spectral index (${\beta}$) from ${\approx}1$ to ${\approx}3$. We find a strong anti-correlation between ${\beta}$ and the fractal dimension of the lightcurves, which provides an independent check of the quality of our modelling of power spectra. We fit a Gaussian function to each flare in a given lightcurve to obtain the flare duration. We discover a correlation between ${\beta}$ and the median duration of the flares. We use the derivative of a lightcurve to obtain a characteristic variability timescale which does not depend on the assumed functional form of the flares, incomplete fitting, and so on. We find that, once the effects of relativistic Doppler boosting on the observed timescales are corrected, the variability timescales of our sources are proportional to the black hole mass to the power of ${\alpha}=1.70{\pm}0.49$. We see an indication for AGNs in different regimes of accretion rate, flat spectrum radio quasars and BL Lac objects, having different scaling relations with ${\alpha}{\approx}1$ and ${\approx}2$, respectively. We find that modelling the periodograms of four of our sources requires the assumption of broken powerlaw spectra. From simulating lightcurves as superpositions of exponential flares we conclude that strong overlap of flares leads to featureless simple power-law periodograms of AGNs at radio wavelengths in most cases (The paper is about to be submitted to ApJ).

  • PDF

Enhanced ART1 Algorithm for the Recognition of Student Identification Cards of the Educational Matters Administration System on the Web (웹 환경 학사관리 시스템의 학생증 인식을 위한 개선된 ART1 알고리즘)

  • Park Hyun-Jung;Kim Kwang-Baek
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.5 s.37
    • /
    • pp.333-342
    • /
    • 2005
  • This paper proposes a method, which recognizes student's identification card by using image processing and recognition technology and can manage student information on the web. The presented scheme sets up an average brightness as a threshold, based on the brightest Pixel and the least bright one for the source image of the ID card. It is converting to binary image, applies a horizontal histogram, and extracts student number through its location. And, it removes the noise of the student number region by the mode smoothing with 3$\times$3 mask. After removing noise from the student number region, each number is extracted using vertical histogram and normalized. Using the enhanced ART1 algorithm recognized the extracted student number region. In this study, we propose the enhanced ART1 algorithm different from the conventional ART1 algorithm by the dynamical establishment of the vigilance parameter. which shows a tolerance limit of unbalance between voluntary and stored patterns for clustering. The Experiment results showed that the recognition rate of the proposed ART1 algorithm was improved much more than that of the conventional ART1 algorithm. So, we develop an educational matters administration system by using the proposed recognition method of the student's identification card.

  • PDF

Tube-Hole Center Detection Vision Algorithm for Verifying Position of Tele-Controlled Robot in Nuclear Steam Generator (원전 증기발생기 내 원격제어 로보트의 위치 검증을 위한 세관중심 검출 비젼 알고리듬)

  • 성시훈;강순주;진성일
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.2
    • /
    • pp.137-145
    • /
    • 1998
  • In this paper, we propose a tube-hole center detection vision algorithm verifying the position of a tele-controlled robot and providing visual information for increasing reliability and efficiency in the diagnosis of steam generator (SG) tubes in nuclear power plant. A tele-controlled robot plays a role in carrying the probe used in inspecting the integrity of SG tubes. Thus accurately locating a tele-controlled robot on the desired tube-hole center is important issue for reliability of inspection. To do this work, we have to find the tube-hole center locations from the input image. At first, we apply the three-class segmentation method modified for this application. WE extract minimum bounding rectangles (MBRs) in the theresholded binary image. Second, for discriminating between MBR by tube and MBR by noise, we introduce the MBR rejection rules as knowledge-based rule set. MBRs are divided into the very dark region MBRs and the very bright region MBRs. In order to describe the region of complete tube-hole, the MBRs need a process of pairing each other. We then can find the tube-hole center from the paired MBR. For more accurately finding the tube-hole center in several sequential images, the centers of some frames need to be averaged. We tested the performance of our method using hundreds of real images.

  • PDF

Evaluation of Phase Calibration Performance with KVN

  • Jung, Dawoon;Sohn, Young-Jong;Byun, Do-Young;Jung, Taehyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.36.2-36.2
    • /
    • 2016
  • In mm-VLBI, the quality of observation data is largely affected by atmospheric effect. The most challenging matter is that the phase of correlator output fluctuates rapidly resulting from a variation of atmospheric propagation delay. Consequently, it is demanding to achieve high Signal-to-Noise ratio by integrating data in time domain before calibrating atmospheric delay. However, Korean VLBI Network (KVN) has a unique system to make a 4-frequency (22/43/86/129 GHz) simultaneous observation in mm-wavelength and Frequency Phase Transfer (FPT) calibration technique has effectively removed atmospheric delay in the simultaneous multi-frequency observation of the KVN. For astrometric and astrophysical studies, we evaluated the FPT performance of KVN in various observing conditions. Using the total 38 bright AGNs, we have compared atmospheric conditions such as ground-based weather information, system temperature, atmospheric delay with the calibration results of FPT at 22/43/86/129 GHz during the five experiments in 2013, and quantified its performance in terms of coherence function and Allan variance. We present the analysis result of the relation between the FPT performance and observing conditions.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Region-adaptive Smear Removal Method Using Optical Black Region for CCD Sensors (광학암흑영역을 이용한 CCD 센서의 영역 적응적 스미어 제거 방식)

  • Han, Young-Seok;Song, Ki-Sun;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.107-116
    • /
    • 2010
  • Smear is a phenomenon that occurs when an extremely strong light source appears in the imaging system with CCD sensor. It occurs due to the signal charge transfer of CCD and appears as bright lines of noise emanating vertically (or horizontally) from the light source. For still images, smear can be reduced by using a mechanical shutter or special drive methods, but these techniques cannot be applied to image sequences. In this paper, we propose a smear removal method that can be applied to imaging systems for not only still images but also image sequences. The proposed method uses the optical black region(OBR) which is a group of pixels located in the boundary of CCD imaging sensors. Although the OBR is not exposed to light, it contains smear information caused by the charge transport. First, noise and the smear signal in the OBR is separated, and noise is removed to correctly estimate smear effect. Then, corrected OBR signal is uniformly subtracted to eliminate smear effect. Also, if saturation is occurred, the current pixel is substituted by weighted summation of neighboring pixels to improve the visual degradation. Experimental results show that the proposed algorithm outperforms the conventional methods.

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).

Near-Infrared Spectroscopy and Modeling of Luminous Blue Variables

  • Kim, Hyun-Jeong;Koo, Bon-Chul;Park, Yong-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.152.1-152.1
    • /
    • 2011
  • We report preliminary results of long-slit near-infrared (NIR) spectroscopy of Luminous Blue Variables (LBVs) with moderate resolution of R ~ 2400. We obtained Jshort (1.04-1.26 micron) and Ks (2.02-2.31 micron) band spectra of 4 LBVs and 3 LBV candidates in Southern hemisphere using IRIS2, infrared imager and spectrograph, mounted on the 4-m Anglo-Australian Telescope. All targets are fairly bright in NIR so that we can obtain high signal-to-noise ratio for clear line detection and modeling. They are also widely distributed in the HR diagram so that we can compare the spectral properties of LBVs in different temperature and luminosity ranges. Among them, we present the results of two well-known LBVs AG Car and HR Car. Their spectra show similar properties with hydrogen, He I, and metallic lines such as Fe II and Mg II, most of them in emission. We discuss, in particular, the He I 1.083 micron lines formed in stellar wind because these two LBVs show large variation in their He I line intensities, compared to previous studies. Since the He I 1.083 line is known to be anticorrelated with the photometric variation of LBVs, strong line intensities with P-Cygni profiles in both stars indicate that they are now near the visual minimum phase. We model the obtained spectra using non-LTE atmosphere code CMFGEN of Hillier (1998) to derive stellar parameters such as wind velocity and mass loss rate, and discuss the long-term variability of stellar parameters of these LBVs. deduced from our otometric solution.

  • PDF

A study on the usage satisfaction of multi-type handpieces with equipped air-jet function (Air-jet기능을 장착한 멀티형 복합유닛 핸드피스의 사용 만족도 조사)

  • Kim, Im-Sun;Choi, Byung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.169-178
    • /
    • 2015
  • Purpose: This study was to investigate usage satisfaction of multi type handpiece with equipped air-jet function Methods: The subjects of this study through the survey was conducted for fifty-nine dental technicians in Daegu and Gyeongsangbukdo from the May 7 to 19, after the June 23 to July 4 2014. The survey was about the function and quality through user testing environment by cutting zirconia specimens using appliance for zirconia. The collected date was analyzed by the statistical program SPSS Win Ver 19.0 for the satisfaction of handpiece and control system. To test for significance on each item, p<0.05 had been decided a standard. General characteristics and relationship between the handpiece and control system was performed correlation analysis. Results: The results of this study is as follows. 35 dental technicians had 1~2 years career in zirconia part as the highest 59.3%, 95% of subjects expected that the prospects for the zirconia material have bright prospects. The satisfaction of multi type handpiece and control system design and function showed a significant difference. Subjects satisfied with the design and function of the multi type showed negative correlation with those of Standard. The satisfaction of multi type handpiece showed 3.37 points of air jet, 3.05 points of noise level, 2.69 points of water flow rate, and 1.98 points of cruise function. Sample differences in all parameters showed a statistically higher difference. Conclusion: High-speed cutting mechanism of multi-type is recommended working with zirconia materials and the multi-type unit combined handpiece motor, air-turbine and air-gun will be expected the increase of user due to the high satisfaction of air jet.