• Title/Summary/Keyword: Bridge scour depth

Search Result 62, Processing Time 0.025 seconds

The study of method local scour protection to the existing piers bridge (기존 교각주변의 국부세굴 방지공법에 관한 연구)

  • Park, Sang-Kil;Chang, Tae-Rae;Park, Byung-Yul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.598-602
    • /
    • 2006
  • Local scour is associate with particular local types of vortex around bridge piers. This paper is method of protection local scour for the existing Busan City subway 3 Line bridge piers and Gupo large bridge piers. In order to take design of protection of local scour this bridge piers, We calculate the local scour hole of depth , scour width, riprap construction , filter construction by formulas. We had experimental hydraulic model test for this bridge piers in order to take proof for the calculation of local scour. We knew that the vortex intensifies the local flow velocities and acts to erode sediment from the scour hole and transport it downstream. As the result of hydraulic model test, we could suggest three types method of protection local scour this bridges. We knew that FHWA HEC-18(Richardson et al. 2001: Modified CSU) Formula is useful to checking calculation as application of field. One is pier protection using the sheet piles and riprap, the others are pier protection using the riprap with filter and to make renew Wall-caisson. The best method of protection for the existing Busan City subway 3 Line bridge piers and Gupo large bridge piers is pier protection using the sheet piles and riprap.

  • PDF

Estimation of Scour Depth at Bridnges and Comparative Analysis between Estimated and Measured Scour Depths (교량에서의 세굴깊이 산정 및 산정치와 실측치의 비교분석)

  • Yun, Yong-Nam;Lee, Jae-Su;Ho, Jeong-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.5
    • /
    • pp.477-485
    • /
    • 1997
  • Recent internal and external bridge failures due to pier and abutment scour have emphasized the need for better methods of scour depth estimation. This paper compares the hydraulic analysis of the Namhan River Bridge over the Namhan River using one-dimensional models. WSPRO & HEC-2, and the two-dimensional model. TABS-MD based on the procedures presented in HEC-18 published by the U.S. FEdral Highway Administration. A comparison of estimated scour depth for this research based on the results from both one-dimensional and two-dimensional model is presented. At the same time, field measurement has been performed before and after flood using sounding instrument. Fathometer (DE-719C). A comparison between estimated and measured scour depth at bridge is also presented. Result shows that there is all the difference between estimated and measured scour depth due to dissimilarity between laboratory and field conditions. Also, it is difficult to measure the maximum scour depth accurately due to refilling. Therefore development of scour measuring equipment which can be used during peak flood, and derivation of empirical model appropriate for internal river system seems urgent.

  • PDF

Applicability Evaluation on the Analytical Formulas of the Scour Depth Estimation in the Bight River (교량세굴심 산정을 위한 만곡부하천에서의 산정식 적용성 평가)

  • Park, Soo-Jin;Park, Jae-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4845-4852
    • /
    • 2012
  • This research calculated the scour depth of bridge according to inflow and outflow changes of stream's flood discharge and curves by applying scour depth formula for piers and abutments, and by comparing and examining them, evaluated the applicability of scour depth formulas. Overall, if the angles of flood discharge and inflow and outflow increase, the deviation rate of scour depth in bight increased. Especially the deviation rate was 58% at the inflow and outflow angle of $105^{\circ}$ that the bridge plan for this geography need careful examination. Next, as a result of calculating the deviation rate of scour depth at the bight by scour depth formulas, in case of pier, Andru formula showed 58% deviation rate, Laursen formula showed 26% deviation rate, and CSU. formula showed 17% deviation rate. In the case of abutment, Froehlich formula shows 44% deviation rate that when applying above scour depth formulas, scour depth calculation considering repairable characteristics of bight is necessary. Finally, about inflow and outflow angles of $45^{\circ}{\sim}135^{\circ}$ that showed big deviation rate of scour depth, this research performed regression analysis of deviation rates of scour depth due to flood discharge to suggest the regression formula.

Evaluation of the Vulnerability of Bridge Foundations to Scour (세굴로 인한 교량기초의 위험도 평가)

  • Kwak, Ki-Seok;Park, Jae-Hyun;Lee, Ju-Hyung;Chung, Moon-Kyung;Kim, Jong-Cheon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.713-718
    • /
    • 2005
  • A methodology is developed to evaluate the vulnerability of bridge piers to scour and to help establish effective disaster measures, taking into account the locality and scour characteristics in Korea. Based on the bearing capacity of bridge foundation-ground integrating system changed by scour, this methodology is able to prioritize bridge foundations reflecting on the geotechnical factors as well as hydraulic ones. The bridge foundation vulnerability to scour is categorized into 7 groups considering the concise information of the bridge foundation-ground integrating system. A case study of implementing this method which includes the analysis of the scour depth and evaluation, and categorizing the scour vulnerability of bridge foundation is presented.

  • PDF

Monitoring bridge scour using dissolved oxygen probes

  • Azhari, Faezeh;Scheel, Peter J.;Loh, Kenneth J.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.145-164
    • /
    • 2015
  • Bridge scour is the predominant cause of overwater bridge failures in North America and around the world. Several sensing systems have been developed over the years to detect the extent of scour so that preventative actions can be performed in a timely manner. These sensing systems have drawbacks, such as signal inaccuracy and discontinuity, installation difficulty, and high cost. Therefore, attempts to develop more efficient monitoring schemes continue. In this study, the viability of using optical dissolved oxygen (DO) probes for monitoring scour depths was explored. DO levels are very low in streambed sediments, as compared to the standard level of oxygen in flowing water. Therefore, scour depths can be determined by installing sensors to monitor DO levels at various depths along the buried length of a bridge pier or abutment. The measured DO is negligible when a sensor is buried but would increase significantly once scour occurs and exposes the sensor to flowing water. A set of experiments was conducted in which four dissolved oxygen probes were embedded at different soil depths in the vicinity of a mock bridge pier inside a laboratory flume simulating scour conditions. The results confirmed that DO levels jumped drastically when sensors became exposed during scour hole evolution, thereby providing discrete measurements of the maximum scour depth. Moreover, the DO probes could detect any subsequent refilling of the scour hole through the deposition of sediments. The effect of soil permeability on the sensing response time was also investigated.

Fied Investigation of Bridge Scours in Small and Medium Streams(1) (우리나라 중.소 하천의 세굴특성 조사연구(1))

  • Yeo, Un-Gwang;Gang, Jun-Gu
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.1
    • /
    • pp.41-47
    • /
    • 1999
  • More than 100 bridges in Korea have been annually collapsed or badly damaged by the scouring around bridge piers, particularly in the flood season. To prevent from such a tragedy, the fundamental study on the bridge scouring is required, which is essential not only to estimate the scour depth with reliability but to take it into consideration in its design. However, it is not easy to find out the physical scour mechanism since many factors on the scour are coupled with. Moreover, there exists none of the measured data sufficiently for the primary research on the bridge scour depths. In this study the field measurements are carried out to provide the fundamental data for the research and the design. Scouring depth, pier width, flow depth, and the approaching velocity and degree of pier nose are measured broadly in small and medium streams. From these measurements the present situation on bridge scours can be understood and some of important factors to affect the stability of bridges are analyzed.

  • PDF

Development of Scour Depth Calculation Equation Based on Hydraulic Model Test Data (수리모형실험 자료를 활용한 교각세굴심 산정식의 개발)

  • Chang, Hyung-Joon;Lee, Ho Jin;Lee, Hyo Sang;Kim, Sung-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.163-168
    • /
    • 2020
  • Since the industrialization in the 1960s, Korea has been expanding its transportation infrastructure, such as building bridges. Owing to bridge construction, studies on stability review have been carried out, and stability-securing technology has been developed. On the other hand, these were applied mainly to the upper part of the bridge, so applications to the lower part are limited. In particular, scour at the bridge pier causes erosion in the riverbed and bridge collapse. Hence, prevention studies and countermeasures are needed. In this study, an empirical formula was developed to evaluate the scour depth of a bridge, which was calculated through multiple linear regression analysis using the hydraulic model study data conducted in previous studies. The formula, which had a value of 0.91, was applied to the model test data that was not used for development to verify the developed formula. When the pier scour depths were compared in 23 cases, the error rate was less than 20% in 16 cases (70%). The empirical formula developed in this study is applicable to pier scour-depth calculations. Further research will be needed to develop a more accurate empirical formula for pier scour-depth calculations, and it is expected to reduce bridge damage caused by scour.

Interdisciplinary Procedure for Scour Estimation at Inchon 2nd Bridge Piers (인천 제2연육교 세굴문제 해결을 위한 학제간 공동연구 방안)

  • Yeo, Woon-Kwang;Kim, Jeong-Hwan;Lee, Yang-Ku;Kim, Tae-In;Kim, Jong-In;Kwak, Ki-Seok;Lee, Jong-Kook;Kwak, Moon-Soo;Kim, Moon-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.71-80
    • /
    • 2005
  • More than 100 bridges have been annually collapsed or seriously damaged by scouring in Korea. It is extremely hard to understand the complicated scour mechanism and estimate the scour depth with accuracy in fields, however since scouring is a very complex manifestation of sediment transport unable to describe with a simple mathematical tool. In order to obtain the reasonable solution to bridge scouring, therefore, the interdisciplinary co-operation is strongly recommended. In this study the special task force team for the scour problems around Incheon 2nd bridge piers is made, in which all kinds of scour oriented researches such as oceangraphic survey, hydraulic model test, numerical simulation, scour rate test, real-time scour monitoring, etc will be carried out. This paper provides this interdisciplinary procedure in details.

  • PDF

Experimental Study for Protection of Local Scouring around Bridge Pier in a Curved Channel (만곡부에 위치한 교각주위의 국부세굴 보호공에 관한 실험적 연구)

  • Choe, In-Ho;Park, Yeong-Jin;Song, Jae-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.3
    • /
    • pp.269-277
    • /
    • 1998
  • Laboratory flume experiments to investigate the characteristics of the flows and local scour around circular bridge pier in a curved channel are performed. In this study, the effect of a circular collar device for controlling the depth of scour is examined. The scour depth with a collar is about 40% of the scour depth without collar in the straight course of the flume while it is about 44% of the scour depth without collar at the location of 150' in the curved channel. As the results of experiments using the collar of which diameter is twice of pier, the reduction of scour depth is the most effective in a straight channel when the location of collar is 0.2h( h:depth) below the channel bottom. And, the reduction of scour depth is the most effective in a curved channel when the location of collar is 0.1h below the channel bottom.

  • PDF