• Title/Summary/Keyword: Breathing pattern

Search Result 101, Processing Time 0.031 seconds

Advanced PEEP Controlled system development (최신PEEP제어 시스템 개발)

  • Kim, Jong-Cheol;Lee, Sang-Hag;Joo, Jung-Kyou
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.137-140
    • /
    • 2008
  • The purpose of PEEP is to increased effect reparation in lung. Recently trend of technology is possible to have multi-level or to control freely for variety breathing pattern or breathing mode. Those new technology need some issue like electronic controlled actuator(solenoid), PEEP valve of special structure and control software in micro controller. This paper brief to develop actuator(solenoid) and PEEP valve. This development is to make commercial product of MEKICS.Co.LTD Electronic controlled actuator(Solenoid) is to make force depend on current in linear. And force is convert to pressure in PEEP valve. Major technical issue are how to make the valve with continuous force even dough moving and how to optimize to convert force - pressure.

  • PDF

Application of curvature of residual operational deflection shape (R-ODS) for multiple-crack detection in structures

  • Asnaashari, Erfan;Sinha, Jyoti K.
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.3
    • /
    • pp.309-322
    • /
    • 2014
  • Detection of fatigue cracks at an early stage of their development is important in structural health monitoring. The breathing of cracks in a structure generates higher harmonic components of the exciting frequency in the frequency spectrum. Previously, the residual operational deflection shape (R-ODS) method was successfully applied to beams with a single crack. The method is based on the ODSs at the exciting frequency and its higher harmonic components which consider both amplitude and phase information of responses to map the deflection pattern of structures. Although the R-ODS method shows the location of a single crack clearly, its identification for the location of multiple cracks in a structure is not always obvious. Therefore, an improvement to the R-ODS method is presented here to make the identification process distinct for the beams with multiple cracks. Numerical and experimental examples are utilised to investigate the effectiveness of the improved method.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

A Study on the Classification of Nursing Diagnoses by Student Nurses (간호학생이 내린 간호진단 분석에 관한 연구)

  • Min, Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.457-471
    • /
    • 1995
  • This research was done to promote improvement of practical application of nursing diagnoses and to improve the quality of nursing. The subjects of this research were 156 second year students of C junior nursing college who were giving adult patient care. The nursing diagnoses of 312 reports were analyzed using NANDA. In these case reports only nursing diagnoses were considered, of which there were a total of 982. In the data analysis the 9H of the nursing students' nursing diagnoses matched with 105 NANDA nursing diagnoses, Of these, the most frequent diagnoses were pain(165, 17.48%), anxiety(101, 10.70%), alteration in nutrition(83, 8.79%) , sleep disturbance (67, 7.10%), in activity intolerance (67, 7.10%), ineffective breathing pattern(51,5.40%). The etiology for the students' nursing diagnoses were compared with NANDA's nursing diagnoses by frequency. The most frequent etiology for the nursing diagnoses of pain was a biological etiology(50, 31%), for anxiety, situation crisis(58, 57.43%), for alteration in nutrition, indigesion(23, 27.71%), for sleep disturbance, external etiology(25, 37.32%), for activity intolerance, immobile position(22, 32.84%), for ineffective breathing pattern, pain(35, 68.63%), and for ,impaired physical mobility, pain(31, 65.96%). The most frequent etiology for constipation was inadquate digestion of water and cellulose (16, 34.78%), for fluid volume felicity, loss of body fluid (21, 52.50%), for impaired skin integrity, external etilogy(16, 43.24%), for impaired physical mobility, pain(22, 62.86%) , for knowledge deficits, cognition disturbance(9, 27.27%), for ineffective air way clearance, secretion obstruction(14, 48.27%) , for impaired gas exchange, loss of transport ability of blood oxygen(9, 37.50%) , and for powerlessness, therapy environment (5, 22.73%). The number of nursing diagnoses by pattern was exchange(16), moving(6), feeling(4), choosing(4), relating(3), communication(1), perceiving(1), knowing(1), valuing(1).

  • PDF

Validity of Nursing Diagnoses Related to Difficulty in Respiratory Function (호흡기능장애와 관련된 간호진단의 타당도 조사)

  • 김조자;이원희;유지수;허혜경;김창희;홍성경
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.4
    • /
    • pp.569-584
    • /
    • 1993
  • This study was done to verify validity of nursing diagnoses related to difficulty in respiratory function. First, content validity was examined by an expert group considering the etiology and the signs / symptoms of three nursing diagnoses - ineffective airway clearance, ineffective breathing pattern, impaired gas exchange. Second, clinical validity was examined by comparing the frequencies of the etiologies and signs / symptoms of the three nursing diagnoses in clinical case studies with the results of the content validity. This study was a descriptive study. The sample consisted of 23 experts (professors, head nurses and clinical instructors) who had had a variety of experiences using nursing diagnoses in clinical practice, and 102 case reports done by senior student nurses of the college of nursing of Y-university. These reports were part of their clinical practice in the ICU. The instrument used for this study was a checklist for etiologies and signs and symptoms based on the literature, Doenges and Moorhouse (1988), Kim, McFarland, McLane (1991), Lee Won Hee et al. (1987), Kim Cho Ja et at. (1988). The data was collected over four month period from May 1992 to Aug. 1992. Data were analyzed using frequencies done with the SPSS / PC+ package. The results of this study are summarized as follows : 1. General Characteristics of the Expert Group A bachelor degree was held by 43.5% and a master or doctoral degree by 56.5% of the expert group. The average age of the expert group was 35.3 years. Their average clinical experience was 9.3 years and their average experience in clinical practice was 5.9 years. The general characteristics of the patients showed that there were more women than men, that the age range was from 1 to over 80. Most of their medical diagnoses were diagnoses related to the respiratory. system, circulation or neurologic system, and 50% or more of them had a ventilator with intubation or a tracheostomy. The number of cases for each nursing diagnoses was : · Ineffective airway clearance, 92 cases. · Ineffective breathing pattern, 18 cases. · Impaired gas exchange, 22 cases. 2. The opinion of the expert group as to the classification of the etiology, and signs and symptoms of the three nursing diagnoses was as follows : · In 31.8% of the cases the classification of etiology was clear. · In 22.7%, the classification of signs and symptoms was clear. · In 17.4%, the classification of nursing interventions was clear. 3. In the expert group 80% or mere agreed to ‘dysp-nea’as a common sign and symptom of the three nursing diagnoses. The distinguishing signs and symptoms of (Ineffective airway clearance) were ‘sputum’, ‘cough’, ‘abnormal respiratory sounds : rales’. The distinguishing sings and symptoms of (Ineffective breathing pattern) were ‘tachypnea’, ‘use of accessory muscle of respiration’, ‘orthopnea’ and for (Impaired gas exchange) it was ‘abnormal arterial blood gas’, 4. The distribution of etiology, and signs and symptoms of the three nursing diagnoses was as follows : · There was a high frequency of ‘increased secretion from the bronchus and trachea’ in both the expert group and the case reports as the etiology of ineffective airway clearance. · For the etiologies for ineffective breathing pat-tern, ‘rain’, ‘anxiety’, ‘fear’, ‘obstructions of the tract, ca and bronchus’ had a high ratio in the ex-pert group and ‘decreased expansion of lung’ in the case reports. · For the etiologies for impaired gas exchanges, ‘altered oxygen -carrying capacity of the blood’ and ‘excess accumulation of interstitial fluid in lung’ had a high ratio in the expert group and ‘altered oxygen supply’ in the case reports. · For signs and symptoms for ineffective airway clearance, ‘dyspnea’, ‘altered amount and character of sputum’ were included by 100% of the expert group. ‘Abnormal respiratory. sound(rate, rhonchi)’ were included by a high ratio of the expert group. · For the signs and symptoms for ineffective breathing pattern. ‘dyspnea’, ‘shortness of breath’ were included by 100% of the expert group. In the case reports, ‘dyspnea’ and ‘tachypnea’ were reported as signs and symptoms. · For the sign and symptoms for impaired gas exchange, ‘hypoxia’ and ‘cyanosis’ had a high ratio in the expert group. In the case report, ‘hypercapnia’, ‘hypoxia’ and ‘inability to remove secretions’ were reported as signs and symptoms. In summary, the similarity of the etiologies and signs and symptoms of the three nursing diagnoses related to difficulty in respiratory function makes it difficult to distinguish among them But the clinical validity of three nursing diagnoses was established through this study, and at last one sign and symp-tom was defined for each diagnosis.

  • PDF

Comparison of Sleep Pattern According to Apnea-Hypopnea Index with Obstructive Sleep Apnea Syndrome (폐쇄성수면무호흡증후군의 무호홉-저호흡 지수에 따른 수면양상의 비교)

  • Jin, Bok-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.264-270
    • /
    • 2007
  • Obstructive sleep apnea syndrome (OSAS) is defined by sleep apnea with decreased oxygen saturation, excessive snoring with daytime sleepiness, and frequent awakening during the night time sleep. The present study was performed to investigate how apnea-hypopnea, that possibly causes breathing disturbance during sleep, can affect sleep pattern in patients with OSAS. We included 115 patients (92 men, 23 women) who underwent a polysomnography from January 2006 to May 2007. As the frequency of sleep apnea-hypopnea increases, the proportion of non-rapid eye movement (REM) sleep (p<0.001), and stage I sleep (p<0.001) increased, while that of stage II sleep (p<0.001), stage III and IV sleep (p<0.01), and REM sleep (p<0.05) decreased. Furthermore, sleep apnea-hypopnea was closely correlated with REM sleep (r=0.314, p<0.001), stage I sleep (r=0.719, p<0.001), stage II sleep (p=-0.342, p<0.05), stage III and IV sleep (r=-0.414, p<0.001), and REM sleep (r=-0.342, p<0.05). Stage I sleep could account for the 51% of the variance of apnea-hyponea. Our study shows sleep apnea-hypopnea affects sleep pattern in pattern with OSAS significantly, and the change of stage I sleep is the most important factor in estimating the disturbance of sleep pattern.

  • PDF

Immediate Effects of Bilateral Pattern with Spiral pattern of PNF on Diaphragm Excursion and Vital Capacity in Normal Adults (정상 성인의 가로막 이동거리 및 폐활량에 대한 고유수용성신경근촉진법 Bilateral pattern with Spiral pattern의 즉각적 효과)

  • Kyoung-Seon Shin;Yu-Gyeong Lee;Eun-Bi Jeong;Dong-Yeop Lee;Ji-Heon Hong;Jae-Ho Yu;Seong-Gil Kim;Jin-Seop Kim
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.151-158
    • /
    • 2023
  • Purpose: This study aimed to examine the immediate effects of different breathing training techniques on diaphragm excursion and vital capacity in healthy adults. Specifically, the study focused on comparing respiratory exercise without PNF, bilateral pattern respiratory exercise, and bilateral pattern with spiral pattern respiratory exercise. Methods: Twenty-seven healthy adults in their 20s participated in the study. Diaphragm excursion and vital capacity were evaluated under three different conditions. A one-way repeated ANOVA was used to analyze the differences in diaphragm excursion and vital capacity among the interventions. Results: Statistically significant differences were observed in diaphragm excursion among the interventions, comparing respiratory exercise without PNF, bilateral pattern respiratory exercise, and bilateral pattern with spiral pattern respiratory exercise. Similarly, statistically significant differences were found in vital capacity among the interventions without PNF respiratory exercise, bilateral pattern respiratory exercise, and bilateral pattern with spiral pattern respiratory exercise. Conclusion: The study demonstrated that incorporating the spiral technique in respiratory exercise led to increased diaphragm excursion and lung capacity compared to other interventions. These findings suggest that PNF respiratory exercise combined with the spiral pattern may have clinical implications for the treatment of respiratory diseases. Further research is warranted to explore the long-term effects and clinical application of these approaches.

Theoretical Analyses of Particle Deposition in a Five-lobe Compartment Human Lung Model (5-엽(葉) 인체 폐 모델에서의 흡입입자 침전해석)

  • 구재학
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.245-246
    • /
    • 2000
  • 공기중의 오염 입자가 인체에 얼마나 많은 영향을 미치는가는 흡입된 입자 (inhaled particles) 중에서 얼마나 많은 양이 폐 (lung)에 침전되는가와 밀접한 관계가 있다. 또한 정상 및 비정상 (diseased) 폐에서, 흡입된 입자의 침전 위치와 침전양 (deposition site and dose)은 입자의 크기와 호흡 양식(breathing pattern)에 따라 큰 차이를 보이며, 이런 차이는 흡입오염입자 (inhaled pollutant particles)에 의한 건강 위험도 평가 (health risk assessment) 및 흡입용 약물 (inhaled drug aerosols)의 치료효과(therapeutic effects) 평가 등에 큰 영향을 미친다. (중략)

  • PDF

Treatment of flail chest with Judet`s struts (Judet`s strut를 이용한 흉벽요동 치료;6례 보고)

  • 이현재
    • Journal of Chest Surgery
    • /
    • v.26 no.10
    • /
    • pp.812-814
    • /
    • 1993
  • Six patients with flail chest were performed operative stabilization with Judet`s Struts.The indications of opertive stabilization were exploratory thoracotomy or laparotomy in 4 patients, and severe chest pain due to displaced ribs which deteriorated respiratory pattern and gas exchange in 2 patients. After operation, all patients became comfortable and complained less pain.Two patients restored spontaneous breathing without ventilator therapy and 2 patients were ventilated during 4 days and 5 days, respectively.There were no morbidity and mortality related to operative stabilization.

  • PDF

Thickness Changes of the Lower Lip in Mouth Breathing Children and Adolescent (구호흡 양상을 보이는 아동 및 청소년의 하순 두께 변화에 관한 연구)

  • Jeong, Young-Ho;Lee, Sang-Min;Yang, Byun-Ho;Park, In-Young;Lee, Il-Hong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.47-56
    • /
    • 2012
  • As attractive lips are important component of appealing faces, the study was conducted to investigate the association of mouth-breathing and thickness of lower lips in mouth-breathers and nasal-breathers. The subjects were 436 adolescent patients aged 8~18 years who took cephalometrics. The results were as follows. The ratio of lower lip thickness to that of upper lip thickness in mouth breathing and nasal breathing groups were $1.13{\pm}0.14$, $1.02{\pm}0.14$, respectively. According to subjects' skeletal pattern, the ratio in Class I sample was $1.05{\pm}0.09$. Class II subjects showed $1.20{\pm}0.12$, and Class III showed $0.97{\pm}0.11$. Mouth - breathers had higher lower/upper lip ratio than nasal breathers meaning their lower lips were thicker. Skeletal Class II patients group showed the most thickest lower lips among Class I, II, III subgroups.