• Title/Summary/Keyword: Breath-hold

Search Result 58, Processing Time 0.032 seconds

Dosimetric Comparison of Setup Errors in Intensity Modulated Radiation Therapy with Deep Inspiration Breath Holding in Breast Cancer Radiation Therapy (Deep Inspiration Breath Holding을 적용한 유방암 세기변조방사선치료 시 위치잡이오차 분석을 통한 선량 평가)

  • Ham, Il-Sik;Cho, Pyong-Kon;Jung, Kang-Kyo
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.137-143
    • /
    • 2019
  • The aim of this study was analyzed the setup error of breast cancer patients in intensity modulated radiation therapy(IMRT) with deep inspiration breath holding(DIBH) and was analyzed the dose distribution due to setup error. A total of 45 breast cancer cases were performed a retrospective clinical analysis of setup error. In addition, the re-treatment planning was carried by shifting the setup error from the isocenter at the treatment. Based on this, the dose distribution of PTV and OARs was compared and analyzed. The 3D error for small breast group and medium breast group and large breast group were 3.1 mm and 3.7 mm and 4.1 mm, respectively. The difference between the groups was statistically significant(P=0.003). DVH results showed HI, CI for the PTV difference between standard treatment plan and re-treatment plan of 14.4%, 4%. The difference in $D_5$ and $V_{20}$ of the ipsilateral lung was 5.6%, 13% respectively. The difference in $D_5$ and $V_5$ of the heart of right breast cancer patients was 6.8%, 8% respectively. The difference in $D_5$, $V_{20}$ of the heart of left breast cancer patients was 7.2%, 23.5% respectively. In this study, there was a significant association between breast size and significant setup error in breast cancer patients with DIBH. In addition, it was found that the dose distribution of the PTV and OARs varied according to the setup error.

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

Evaluation of Dose Reduction of Cardiac Exposure Using Deep-inspiration Breath Hold Technique in Left-sided Breast Radiotherapy (좌측 유방암 방사선 치료에서 깊은 들숨 호흡법을 이용한 심장 선량 감소 평가)

  • Jung, Joo-Young;Kim, Min-Joo;Jung, Jae-Hong;Lee, Seu-Ran;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.278-283
    • /
    • 2013
  • Breast cancer is the leading cause of cancer death in women worldwide and the number of women breast cancer patient was increased continuously. Most of breast cancer patient has suffered from unnecessary radiation exposure to heart, lung. Low radiation dose to the heart could lead to the worsening of preexisting cardiovascular lesions caused by radiation induced pneumonitis. Also, several statistical reports demonstrated that left-sided breast cancer patient showed higher mortality than right-sided breast cancer patient because of heart disease. In radiation therapy, Deep Inspiration Breath Hold (DIBH) technique which the patient takes a deep inspiration and holds during treatment and could move the heart away from the chest wall and lung, has showed to lead to reduction in cardiac volume and to minimize the unnecessary radiation exposure to heart during treatment. In this study, we investigated the displacement of heart using DIBH CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Treatment planning was performed on the computed tomography (CT) datasets of 10 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ${\geq}95%$ of the prescribed dose and that the volume inside the CTV receiving >107% of the prescribed dose should be minimized. Scar boost irradiation was not performed in this study. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. The present study demonstrates that cardiac dose during left-sided breast radiotherapy can be reduced by applying DIBH breathing control technique.

Evaluation of the heart and lung dosimetric parameters in deep inspiration breath hold using 3D Slicer

  • Eskandari, Azam;Nasseri, Shahrokh;Gholamhosseinian, Hamid;Hosseini, Sare;Farzaneh, Mohammad Javad Keikhai;Keramati, Alireza;Naji, Maryam;Rostami, Atefeh;Momennezhad, Mehdi
    • Radiation Oncology Journal
    • /
    • v.38 no.1
    • /
    • pp.68-76
    • /
    • 2020
  • Purpose: The present study was conducted to compare dosimetric parameters for the heart and left lung between free breathing (FB) and deep inspiration breath hold (DIBH) and determine the most important potential factors associated with increasing the lung dose for left-sided breast radiotherapy using image analysis with 3D Slicer software. Materials and Methods: Computed tomography-simulation scans in FB and DIBH were obtained from 17 patients with left-sided breast cancer. After contouring, three-dimensional conformal plans were generated for them. The prescribed dose was 50 Gy to the clinical target volume. In addition to the dosimetric parameters, the irradiated volumes and both displacement magnitudes and vectors for the heart and left lung were assessed using 3D Slicer software. Results: The average of the heart mean dose (Dmean) decreased from 5.97 to 3.83 Gy and V25 from 7.60% to 3.29% using DIBH (p < 0.001). Furthermore, the average of Dmean for the left lung was changed from 8.67 to 8.95 Gy (p = 0.389) and V20 from 14.84% to 15.44% (p = 0.387). Both of the absolute and relative irradiated heart volumes decreased from 42.12 to 15.82 mL and 8.16% to 3.17%, respectively (p < 0.001); however, these parameters for the left lung increased from 124.32 to 223.27 mL (p < 0.001) and 13.33% to 13.99% (p = 0.350). In addition, the average of heart and left lung displacement magnitudes were calculated at 7.32 and 20.91 mm, respectively. Conclusion: The DIBH is an effective technique in the reduction of the heart dose for tangentially treated left sided-breast cancer patients, without a detrimental effect on the left lung.

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Chemical Saturation Breath-hold Fast MR Imaging for characterization of Regional Fatty Changes in Liver (화학적 포화 호흡정지 급속 자기공명영상에서 국소적 간지방병변의 특성화)

  • 김동국;유정식;김태훈;오세정;김지형
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.135-141
    • /
    • 1997
  • Purpose: To assess the usefulness of breath-hold fast MR imaging of liver with fat suppression (FS) by application of chemical saturation technique in the diagnosis of regional fatty changes suspected in sonography. Materials and Methods: Thirteen patients who had focal lesions with diffuse, homogeneous signal changes after FS through chemical saturation technique without additional changes of imaging parameter during MR imaging of liver were selected. T1-weighted fast low-angle shot and T2-weighted turbo spin-echo sequences were obtained with or without FS during each single breath-holding session. Subjective changes of signal intensity between the pre-FS and the FS images were compared with the sonographic findings in each lesion. Results: Seven lesions of decreased signal intensity after FS on T1 or T2-weighted images, including three lesions only at FS T1 images, were regarded as focal fat infiltration. All seven lesions had compatible sonographic findings as homogenously echogenic areas. Another six lesions of subjectively increased signal intensity including two lesions only at FS T2 images were regarded as focal fat sparing. All six lesions had sonographic findings as homogenous echo poor areas suggesting focal fat sparing. In cases regarded as fat infiltration, score changes were more prominent at FS T1 images than FS T2 images(p=0.0002). In cases regarded as fat sparing, score changes were more prominent at FS T2 images than FS T1 images(p=0.042). Conclusion: Breath-hold fast T1 and T2-weighted MR imaging with and without chemical saturation pre-pulse may be sufficient for characterization of regional fatty changes in the differential diagnosis of focal hepatic lesion found at sonography.

  • PDF

Utility Estimation of the Application of Auditory-Visual-Tactile Sense Feedback in Respiratory Gated Radiation Therapy (호흡동조방사선치료 시 Real Time Monitor와 Ventilator의 유용성 평가)

  • Jo, Jung Hun;Kim, Byeong Jin;Roh, Shi Won;Lee, Hyeon Chan;Jang, Hyeong Jun;Kim, Hoi Nam;Song, Jae Hun;Kim, Young Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the possibility to optimize the gated treatment delivery time and maintenance of stable respiratory by the introduction of breath with the assistance of auditory-visual-tactile sense. Materials and Methods: The experimenter's respiration were measured by ANZAI 4D system. We obtained natural breathing signal, monitor-induced breathing signal, monitor & ventilator-induced breathing signal, and breath-hold signal using real time monitor during 10 minutes beam-on-time. In order to check the stability of respiratory signals distributed in each group were compared with means, standard deviation, variation value, beam_time of the respiratory signal. Results: The stability of each respiratory was measured in consideration of deviation change studied in each respiratory time lapse. As a result of an analysis of respiratory signal, all experimenters has showed that breathing signal used both Real time monitor and Ventilator was the most stable and shortest time. Conclusion: In this study, it was evaluated that respiratory gated radiation therapy with auditory-visual-tactual sense and without auditory-visual-tactual sense feedback. The study showed that respiratory gated radiation therapy delivery time could significantly be improved by the application of video feedback when this is combined with audio-tactual sense assistance. This delivery technique did prove its feasibility to limit the tumor motion during treatment delivery for all patients to a defined value while maintaining the accuracy and proved the applicability of the technique in a conventional clinical schedule.

  • PDF

Preliminary Study on Pattern Questionnaire for Damum Patterns (담음변증(痰飮辨證) 설간(設間) 개발(開發)을 위한 문헌연구(文獻硏究))

  • Park, Jae-Sung;Kim, Min-Yong;Park, Yong-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.1
    • /
    • pp.54-63
    • /
    • 2006
  • Objectives: In this study a pattern questionnaire for damum patterns was developed by means of literature review and statistical analysis. The individual approach of korean medicine is based on the concept of pattern identification, the objectivity and validity issues of which hold important meaning in the pratice and research. Methods: Review of literatures led to the selection of 22 items describing Dam or Um pattern. A preliminary questinnaire consisted of these items that may be scored with positive score at zero to seven. Results: Damum is all over the body syndromes. That is abnormal body conditions. Damun arouse body pain, breath disorder, digestion disorder, nerves disorder, excretion disorder. Conclusions: Review of literatures led to selection of 29 items describing Damun. A questionnaire is in preparation.

  • PDF