• Title/Summary/Keyword: Breast imaging

Search Result 413, Processing Time 0.041 seconds

Validation of Electrical Impedance Tomography Qualitative and Quantitative Values and Comparison of the Numeric Pain Distress Score against Mammography

  • Juliana, Norsham;Shahar, Suzana;Chelliah, Kanaga Kumari;Ghazali, Ahmad Rohi;Osman, Fazilah;Sahar, Mohd Azmani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5759-5765
    • /
    • 2014
  • Electrical impedance tomography (EIT) is a potential supplement for mammogram screening. This study aimed to evaluate and feasibility of EIT as opposed to mammography and to determine pain perception with both imaging methods. Women undergoing screening mammography at the Radiology Department of National University of Malaysia Medical Centre were randomly selected for EIT imaging. All women were requested to give a pain score after each imaging session. Two independent raters were chosen to define the image findings of EIT. A total of 164 women in the age range from 40 to 65-year-old participated and were divided into two groups; normal and abnormal. EIT sensitivity and specificity for rater 1 were 69.4% and 63.3, whereas for rater 2 they were 55.3% and 57.0% respectively. The reliability for each rater ranged between good to very good (p<0.05). Quantitative values of EIT showed there were significant differences in all values between groups (ANCOVA, p<0.05). Interestingly, EIT scored a median pain score of $1.51{\pm}0.75$ whereas mammography scored $4.15{\pm}0.87$ (Mann Whitney U test, p<0.05). From these quantitative values, EIT has the potential as a health discriminating index. Its ability to replace image findings from mammography needs further investigation.

Determination of Optimal Scan Time for the Measurement of Downstream Metabolites in Hyperpolarized 13C MRSI

  • Lee, Hansol;Lee, Joonsung;Joe, Eunhae;Yang, Seungwook;Choi, Young-suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.212-217
    • /
    • 2015
  • Purpose: For a single time-point hyperpolarized $^{13}C$ magnetic resonance spectroscopy imaging (MRSI) of animal models, scan-time window after injecting substrates is critical in terms of signal-to-noise ratio (SNR) of downstream metabolites. Pre-scans of time-resolved magnetic resonance spectroscopy (MRS) can be performed to determine the scan-time window. In this study, based on two-site exchange model, protocol-specific simulation approaches were developed for $^{13}C$ MRSI and the optimal scan-time window was determined to maximize the SNR of downstream metabolites. Materials and Methods: The arterial input function and conversion rate constant from injected substrates (pyruvate) to downstream metabolite (lactate) were precalibrated, based on pre-scans of time-resolved MRS. MRSI was simulated using two-site exchange model with considerations of scan parameters of MRSI. Optimal scan-time window for mapping lactate was chosen from simulated lactate intensity maps. The performance was validated by multiple in vivo experiments of BALB/C nude mice with MDA-MB-231 breast tumor cells. As a comparison, MRSI were performed with other scan-time windows simply chosen from the lactate signal intensities of pre-scan time-resolved MRS. Results: The optimal scan timing for our animal models was determined by simulation, and was found to be 15 s after injection of the pyruvate. Compared to the simple approach, we observed that the lactate peak signal to noise ratio (PSNR) was increased by 230%. Conclusion: Optimal scan timing to measure downstream metabolites using hyperpolarized $^{13}C$ MRSI can be determined by the proposed protocol-specific simulation approaches.

Analysis of Forest Stand Structure Using Spaceborne Synthetic Aperture Radar(SAR) Data (인공위성 레이다 영상자료를 이용한 임분구조의 물리적 특성파악)

  • 이규성
    • Korean Journal of Remote Sensing
    • /
    • v.8 no.2
    • /
    • pp.79-91
    • /
    • 1992
  • With recent development in spaceborne imaging radar system, there are growing interests using satellite synthetic aperture radar(SAR) data in various applications. This study attempted to identify the relationships between several forest stand characteristics and radar backscatter, measured from space altitude altitude at three incidence angles. Shuttle Imaging Radar-B(SIR-B) data were collected over a forested area in northern Florida in October, 1984. By using various sources of reference data (forest type maps, inventory records, aerial photographs, and Landsat Thematic Mapper data), about 400 forest stands of known characteristics were carefully located in the radar data. Relative radar backscatter for the three incidence angles of SIR-B data were compared with known forest stand parameters such as mean tree height, diameter at breast height(DBH), stand density, biomass, and relative amount of understory vegetation. The results show that these stand parameters have statistically significant correlations with the radar backscatter. In addition, the SIR-B radar backscatter from a certain stand parameter turned out differently at the three different incidence angles. Finally, the types and characteristics of currently available satellite SAR data are discussed.

Synthesis and evaluation of 64Cu-labeled avidin for lymph node imaging

  • Kang, Choong Mo;Kim, Hyunjung;Lee, Yong Jin;Choe, Yearn Seong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • Sentinel lymph node (SLN) imaging plays an important role in surgery of patients with breast cancer and melanoma. In this study, avidin (Av), a tetrameric protein glycosylated with mannose and N-acetylglucosamine molecules, was labeled with $^{64}Cu$ and then evaluated for LN imaging. $^{64}Cu$-Labeled $NeutrAvidin^{TM}$ (NAv), a non-glycosylated form of Av, was used for comparison. 1,4,7,10-Tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA)-conjugated Av and NAv were prepared from the corresponding proteins and DOTA-NHS ester, which were then labeled with copper-64 and purified using PD-10 columns. The numbers of DOTA molecules conjugated to Av and NAv were 4.9 and 3.3, respectively. [$^{64}Cu$]Cu-DOTA-conjugated Av and NAv were prepared in 93% and 73% radiochemical yields, respectively. In vitro serum stability study showed that copper-64 remained stable on all radiotracers for 24 h (>97%). MicroPET/CT images showed that high radioactivity was accumulated in LNs within 15 min after footpad-injection of radiotracers. Tissue distribution data of mice demonstrated significantly higher uptake in the popliteal (PO) LN than lumbar (LU) LN for $^{64}Cu$-labeled Av (relative % ID/g excluding the injection sites: 66.2% and 26.0%, respectively) compared with those of $^{64}Cu$-labeled NAv (43.0% and 49.2%, respectively). The results of this study suggest that mannose molecules on Av enabled the radiotracer to retain in the first LN after mouse footpad-injection.

Usefulness of Three-Dimensional Maximal Intensity Projection (MIP) Reconstruction Image in Breast MRI (유방자기공명영상에서 3 차원 최대 강도 투사 재건 영상의 유용성)

  • Kim, Hyun-Sung;Kang, Bong-Joo;Kim, Sung-Hun;Choi, Jae-Jeong;Lee, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.183-189
    • /
    • 2009
  • Purpose : To evaluate the usefulness of three-dimensional (3D) maximal intensity projection (MIP) reconstruction method in breast MRI. Materials and Methods : Total 54 breasts of consecutive 27 patients were examined by breast MRI. Breast MRI was performed using GE Signa Excite Twin speed (GE medical system, Wisconsin, USA) 1.5T. We obtained routine breast MR images including axial T2WI, T1WI, sagittal T1FS, dynamic contrast-enhanced T1FS, and subtraction images. 3D MIP reconstruction images were obtained as follows; subtraction images were obtained using TIPS and early stage of contrast-enhanced TIPS images. And then 3D MIP images were obtained using the subtraction images through advantage workstation (GE Medical system). We detected and analyzed the lesions in the 3D MIP and routine MRI images according to ACR $BIRADS^{(R)}$ MRI lexicon. And then we compared the findings of 3D MIP and those of routine breast MR images and evaluated whether 3D MIP had additional information comparing to routine MR images. Results : 3D MIP images detect the 43 of 56 masses found on routine MR images (76.8%). In non-mass like enhancement, 3D MIP detected 17 of 20 lesions (85 %). And there were one hundred sixty nine foci at 3D MIP images and one hundred nine foci at routine MR images. 3D MIP images detected 14 of 23 category 3 lesions (60.9%), 11 of 16 category 4 lesions (68.87%), 28 of 28 Category 5 lesions (100%). In analyzing the enhancing lesions at 3D MIP images, assessment categories of the lesions were correlated as the results at routine MR images (p-value < 0.0001). 3D MIP detected additional two daughter nodules that were descriped foci at routine MR images and additional one nodule that was not detected at routine MR images. Conclusion : 3D MIP image has some limitations but is useful as additional image of routine breast MR Images.

  • PDF

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

Assessment of Breast Cancer Knowledge among Health Workers in Bangui, Central African Republic: a Cross-sectional study

  • Balekouzou, Augustin;Yin, Ping;Pamatika, Christian Maucler;Nambei, Sylvain Wilfrid;Djeintote, Marceline;Doromandji, Eric;Gouaye, Andre Richard;Yamba, Pascal Gastien;Guessy, Elysee Ephraim;Ba-Mpoutou, Bertrand;Mandjiza, Dieubeni Rawago;Shu, Chang;Yin, Minghui;Fu, Zhen;Qing, Tingting;Yan, Mingming;Mella, Grace;Koffi, Boniface
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.3769-3776
    • /
    • 2016
  • Background: Breast cancer is the leading cause of cancer deaths among women worldwide. High breast cancer mortality has been attributed to lack of public awareness of the disease. Little is known about the level of knowledge of breast cancer in Central African Republic. This study aimed to investigate the knowledge of health professionals on breast cancer. Materials and Methods: This cross-sectional study was conducted among 158 health professionals (27 medical; 131 paramedical) in 17 hospitals in Bangui using a self-administered questionnaire. Descriptive statistical analysis, Person's ${\chi}^2$ test and ANOVA were applied to examine associations between variables with p < 0.05 being considered significant. Results: Data analyzed using SPSS version 20 indicates that average knowledge about breast cancer perception of the entire population was 47.6%, diagnosis method 45.5%, treatment 34.3% and risk factors 23.8%. Most respondents (65.8%) agreed that breast cancer is important in Central African Republic and that family history is a risk factor (44.3%). Clinical assessments and mammography were considered most suitable diagnostic methods, and surgery as the best treatment. The knowledge level was significantly higher among medical than paramedical staff with regard to risk factors, diagnosis and treatment. However the trainee group had very high significant differences of knowledge compared with all other groups. Conclusions: There is a very urgent need to update the various training programs for these professionals, with recommendations of retraining. Health authorities must create suitable structures for the overall management of cancer observed as a serious public health problem.

Metastatic gastric adenocarcinoma to the mandible (하악에 전이된 위 선양암종)

  • Lee Ji-Un;Kwon Ki-Jeong;Ahn Hyoung-Suk;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.35 no.3
    • /
    • pp.179-183
    • /
    • 2005
  • Metastatic tumors to the jaw bones are uncommon. The most common metastatic tumors to the jaw bones are the breast, lung and kidney. In the jaw bones, the common location of the lesions is the mandible, and the posterior area of the mandible is more commonly affected. The radiographic appearance is quite variable. In this report, a very rare case of metastatic gastric adenocarcinoma to the mandible is presented. The patient had undergone a gastrectomy 3 years ago.

  • PDF