• 제목/요약/키워드: Breast Tumor Diagnosis

검색결과 192건 처리시간 0.023초

악성 종양 환자에 대한 DR-$70^{TM}$ 면역 분석법의 의의: Validation Study (Meaning of the DR-$70^{TM}$ Immunoassay for Patients with the Malignant Tumor)

  • 이기호;조동희;김상만;이득주;김광민
    • IMMUNE NETWORK
    • /
    • 제6권1호
    • /
    • pp.43-51
    • /
    • 2006
  • Background: The DR-$70^{TM}$ immunoassay is a newly developed cancer diagnostic test which quantifies the serum fibrin degradation products (FDP), produced during fibrinolysis, by antibody reaction. The purpose of this study was to evaluate the potential of DR-$70^{TM}$ Immunoassay in screening malignant tumor. Methods: Sample subjects were 4,169 adults, both male and female, who visited the health promotion center of a general hospital from March 2004 to April 2005 and underwent the DR-$70^{TM}$ immunoassay test and other tests for cancer diagnosis. The patient group was defined as 42 adults out of the sample subjects who were newly diagnosed with cancer during the same time period when the DR-$70^{TM}$ immunoassay test was performed. Final confirmation of a malignant tumor was made by pathological analysis. Results: The mean DR-$70^{TM}$ level was $0.83{\pm}0.65{\mu}g/ml$ (range: 0.00 (0.0001)${\sim}7.42{\mu}g/ml)$ in the control group (n=4,127) as opposed to $2.70{\pm}2.33{\mu}g/ml$ (range: $0.12{\sim}9.30{\mu}g/ml)$ in the cancer group (n=42), and statistical significance was established (p<0.0001, Student t-test). When categorized by the type of malignant tumor, all cancer patients with the exception of the subgroups of colon and rectal cancer showed significantly higher mean DR-$70^{TM}$ levels compared with the control group (p<0.0001, Kruscal-Wallis test). The receiver operating characteristic (ROC) curve analysis revealed ${\geq}1.091{\mu}g/ml$ as the best cut-off value. Using this cut-off value, the DR-$70^{TM}$ immunoassay produced a sensitivity of 71.4%, a specificity of 70.1%, a positive predictability of 69.4%, and a negative predictability of 69.2% (1). Conclusion: A significant increase in the mean DR-$70^{TM}$ value was observed in the cancer group (thyroidal, gastric, breast, hepatic and ovarian) com pared with the control group. In particular, the specificity and sensitivity of the DR-$70^{TM}$ immunoassay was relatively high in the subgroups of breast, gastric, and thyroidal cancer patients. There is need for further studies on a large number of malignant tumor patients to see how the DR-$70^{TM}$ level might be changed according to the differentiation grade and postoperative prognosis of the malignant tumor.

Impact of Surveillance Mammography Intervals Less Than One Year on Performance Measures in Women With a Personal History of Breast Cancer

  • Janie M. Lee;Laura E. Ichikawa;Karen J. Wernli;Erin J. A. Bowles;Jennifer M. Specht;Karla Kerlikowske;Diana L. Miglioretti;Kathryn P. Lowry;Anna N. A. Tosteson;Natasha K. Stout;Nehmat Houssami;Tracy Onega;Diana S. M. Buist
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.729-738
    • /
    • 2023
  • Objective: When multiple surveillance mammograms are performed within an annual interval, the current guidance for oneyear follow-up to determine breast cancer status results in shared follow-up periods in which a single breast cancer diagnosis can be attributed to multiple preceding examinations, posing a challenge for standardized performance assessment. We assessed the impact of using follow-up periods that eliminate the artifactual inflation of second breast cancer diagnoses. Materials and Methods: We evaluated surveillance mammograms from 2007-2016 in women with treated breast cancer linked with tumor registry and pathology outcomes. Second breast cancers included ductal carcinoma in situ or invasive breast cancer diagnosed during one-year follow-up. The cancer detection rate, interval cancer rate, sensitivity, and specificity were compared using different follow-up periods: standard one-year follow-up per the American College of Radiology versus follow-up that was shortened at the next surveillance mammogram if less than one year (truncated follow-up). Performance measures were calculated overall and by indication (screening, evaluation for breast problem, and short interval follow-up). Results: Of 117971 surveillance mammograms, 20% (n = 23533) were followed by another surveillance mammogram within one year. Standard follow-up identified 1597 mammograms that were associated with second breast cancers. With truncated follow-up, the breast cancer status of 179 mammograms (11.2%) was revised, resulting in 1418 mammograms associated with unique second breast cancers. The interval cancer rate decreased with truncated versus standard follow-up (3.6 versus 4.9 per 1000 mammograms, respectively), with a difference (95% confidence interval [CI]) of -1.3 (-1.6, -1.1). The overall sensitivity increased to 70.4% from 63.7%, for the truncated versus standard follow-up, with a difference (95% CI) of 6.6% (5.6%, 7.7%). The specificity remained stable at 98.1%. Conclusion: Truncated follow-up, if less than one year to the next surveillance mammogram, enabled second breast cancers to be associated with a single preceding mammogram and resulted in more accurate estimates of diagnostic performance for national benchmarks.

Digital Breast Tomosynthesis versus MRI as an Adjunct to Full-Field Digital Mammography for Preoperative Evaluation of Breast Cancer according to Mammographic Density

  • Haejung Kim;So Yeon Yang;Joong Hyun Ahn;Eun Young Ko;Eun Sook Ko;Boo-Kyung Han;Ji Soo Choi
    • Korean Journal of Radiology
    • /
    • 제23권11호
    • /
    • pp.1031-1043
    • /
    • 2022
  • Objective: To compare digital breast tomosynthesis (DBT) and MRI as an adjunct to full-field digital mammography (FFDM) for the preoperative evaluation of women with breast cancer based on mammographic density. Materials and Methods: This retrospective study enrolled 280 patients with breast cancer who had undergone FFDM, DBT, and MRI for preoperative local tumor staging. Three radiologists independently sought the index cancer and additional ipsilateral and contralateral breast cancers using either FFDM alone, DBT plus FFDM, or MRI plus FFDM. Diagnostic performances across the three radiologists were compared among the reading modes in all patients and subgroups with dense (n = 186) and non-dense breasts (n = 94) according to mammographic density. Results: Of 280 patients, 46 (16.4%) had 48 additional (39 ipsilateral and nine contralateral) cancers in addition to the index cancer. For index cancers, both DBT plus FFDM and MRI plus FFDM showed sensitivities of 100% in the non-dense group. In the dense group, DBT plus FFDM showed lower sensitivity than that of MRI plus FFDM (94.6% vs. 99.6%, p < 0.001). For additional ipsilateral cancers, DBT plus FFDM showed specificity and positive predictive value (PPV) of 100% in the non-dense group, but sensitivity and negative predictive value (NPV) were not statistically different from those of MRI plus FFDM (p > 0.05). In the dense group, DBT plus FFDM showed higher specificity (98.2% vs. 94.1%, p = 0.005) and PPV (83.1% vs. 65.4%; p = 0.036) than those of MRI plus FFDM, but lower sensitivity (59.9% vs. 75.3%; p = 0.049). For contralateral cancers, DBT plus FFDM showed higher specificity than that of MRI plus FFDM (99.0% vs. 96.7%, p = 0.014), however, the other values did not differ (all p > 0.05) in the dense group. Conclusion: DBT plus FFDM showed an overall higher specificity than that of MRI plus FFDM regardless of breast density, perhaps without substantial loss in sensitivity and NPV in the diagnosis of additional cancers. Thus, DBT may have the potential to be used as a preoperative breast cancer staging tool.

Clinicopathologic and Demographic Evaluation of Triple-Negative Breast Cancer Patients among a Turkish Patient Population: a Single Center Experience

  • Somali, Isil;Ustaoglu, Bahar Yakut;Tarhan, Mustafa Oktay;Yigit, Seyran Ceri;Demir, Lutfiye;Ellidokuz, Hulya;Erten, Cigdem;Alacacioglu, Ahmet
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권10호
    • /
    • pp.6013-6017
    • /
    • 2013
  • Background: To evaluate the clinicopathologic and demographic characteristics of triple-negative breast cancer (TNBC) patients and to determine differences from non-triple-negative cases. Materials and Methods: A detailed review of the medical records of 882 breast cancer (BC) patients was conducted to obtain information regarding age, menopausal status, height and weight at the time of diagnosis, presence of diabetes or hypertension, and pathologic characteristics of the tumor (tumor size, lymph node status, histologic grade, ER status, PR status, HER2 status, p53 mutation). Body mass index (BMI) was calculated and a value of ${\geq}30$ was considered as indicative of obesity. Results: 14.9% (n=132) of the patients had TNBC. There was no difference among the patients in terms of median age, comorbid conditions and menopausal status. The proportion of medullary, tubular and mucinous carcinomas was significantly higher (15.9%) in the triple-negative (TN) group, while invasive lobular histology was more frequent (8.2%) among non-triple negative (NTN) cases (p<0.001). Grade 3 (G3) tumors were more frequent in the triple-negative group (p<0.001). The rate of p53 mutation was 44.3% in TN tumors versus 28.2% in the NTN group (p<0.001). The two groups were similar in terms of LN metastasis. In the NTN group, the rate of patients with BMI ${\geq}30$ was 53% among postmenopausal patients, while it was 36% among premenopausal women, and the difference was statistically significant (p<0.001). No significant difference was observed in terms of BMI between postmenopausal and premenopausal patients in the TN group (p=0.08). Conclusions: TNBC rates and clinicopathologic characteristics of the Turkish patient population were consistent with the data from Europe and America. However, no relationship between obesity and TNBC was observed in our study. The association between TNBC and obesity needs to be evaluated in a larger patient population.

유방 병변 256례의 세침흡인 세포학적 진단 및 조직학적 진단과의 비교연구 (Comparison of Fine Needle Aspiration Cytologic Diagnoses and Histologic Diagnoses in 256 Breast Lesions)

  • 강미선;정수진;윤혜경
    • 대한세포병리학회지
    • /
    • 제8권2호
    • /
    • pp.120-128
    • /
    • 1997
  • Fine needle aspiration cytology of breast lesion is well known as a simple, economic and effective diagnostic modality. For the evaluation of cytohistologic correlation, 256 cases of cytologic smears and subsequent histologic sections during 2-year period from Jan. 1995 to Dec. 1996 were reviewed. 1. Fifteen cases(5.9%) were proven as insufficient for evaluation, and 13 of them were fibrocystic change histologically. One case of carcinoma exhibiting sufficient amount of aspirates with no malignant cells on smear was regarded as inadequate. 2. Cytohistologic correlation of 240 cases revealed sensitivity 87.0%, specificity 100.0%, positive predictive value 100.0%, negative predictive value 97.0%, false positive rate 0.0% and false negative rate 13.0%. Total diagnostic accuracy is 95.7%. 3. Total 6 cases of negative were due to small amount of aspirates containing scantiness of malignant cells in two and underestimation in four. 4. Diagnostic concordance rates of fibrocystic change and fibroadenoma were 95.5% and 80.0%, respectively. Diagnostic discrepancies were noted in 7 cases of fibrocystic change and 6 cases of fibroadenoma, however, cytologic discrimination of two entities was not easy in seven of them. 5. In a case of phyllodes tumor and a case of duct ectasia, the discrepancy was due to targeting error. Other three cases(lymphoma, adenomyoepithelioma and granulomatous mastitis) were misinterpreted because of poor acquaintance with those entities. Diagnostic accuracy of fine needle aspiration cytology of breast lesions are relatively high. However, good technique on aspiration and adequate interpretation are necessary to reduce the false negative rate and the discrepancy between cytologic and histologic diagnoses.

  • PDF

한국의 건강검진 현황 (Current Status of Health Screening in Korea)

  • 조한익
    • 한국건강관리협회지
    • /
    • 제2권3호
    • /
    • pp.73-96
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea Most of the health screening programmes focused upon detection of risk factors and diagnosis of life - style related diseases (diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers (stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus) , infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites) , chronic obstructive respiratory diseases, chronic renal diseases (bacteriuria hematuria, proteinuria) , anemia, glaucoma, hearing loss, Alzheimer disease, stress, early psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests (CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests (HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray (chest PA, CT) , endoscopy (gastroscopy, colonoscopy) , sonography(abdomen, thyroid, pelvis, breast) ,cytology (cervix) , bone density, tumor markets (NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MRI, MRT/Angio, molecular testings) were widely used in hospital health screening programmes .In summary, a variety of tests were utilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few program used tests to excess disregarding health screening subjects.

  • PDF

국내 주요 기관의 건강진단 검사 종목

  • 조한익;김상인
    • 한국건강관리협회지
    • /
    • 제2권1호
    • /
    • pp.9-25
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items of major health screening program in Korea. Most, of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis), cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infections diseases(hepatitis, tuberculosis, sexually-transmitted diseases, parasites), chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress and earlypsychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests( CBC, urinalysis, liver function tests, lipid tests, glucose, HbA1c, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT) endoscopy(gastroscopy, colonoscopy), sonography (abdomen, thyroid, pelvis, breast), cytology(cervix), bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA125, PSA and eye tests. Advanced technologies, like CT, PET, MRI, MRI/Angio, molecular testing were widly used in hospital based health screening programmes. In summary, a variety of tests were untilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few programs used tests excessvely disregarding health screening subjects.

  • PDF

한국의 건강검진 현황 (Current Status of Health Screening in Korea)

  • 조한익
    • 한국건강관리협회지
    • /
    • 제2권2호
    • /
    • pp.215-230
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea. Most of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites),chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress, early Psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests(CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT), endoscopy (gastroscopy, colonoscopy) , sonography(abdormen, thyroid, pelvis, breast) , cytology(cervix) ,bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MIRI, MIRI/Angio, molecular testings) were widely usedin hospital health screening programmes. In summary, a variety of were utilized by stages or programmes, however a few subjects. tests were utilized in health screening in Korea. Those tests according to sex and age in most of health screening program used tests to excess disregarding health screening subject.

  • PDF

Impact of the human body in wireless propagation of medical implants for tumor detection

  • Morocho-Cayamcela, Manuel Eugenio;Kim, Myung-Sik;Lim, Wansu
    • 인터넷정보학회논문지
    • /
    • 제21권2호
    • /
    • pp.19-26
    • /
    • 2020
  • This paper analyses the feasibility of using implantable antennas to detect and monitor tumors. We analyze this setting according to the wireless propagation loss and signal fading produced by human bodies and their environment in an indoor scenario. The study is based on the ITU-R propagation recommendations and prediction models for the planning of indoor radio communication systems and radio local area networks in the frequency range of 300 MHz to 100 GHz. We conduct primary estimations on 915 MHz and 2.4 GHz operating frequencies. The path loss presented in most short-range wireless implant devices does not take into account the human body as a channel itself, which causes additional losses to wireless designs. In this paper, we examine the propagation through the human body, including losses taken from bones, muscles, fat, and clothes, which results in a more accurate characterization and estimation of the channel. The results obtained from our simulation indicates a variation of the return loss of the spiral antenna when a tumor is located near the implant. This knowledge can be applied in medical detection, and monitoring of early tumors, by analyzing the electromagnetic field behavior of the implant. The tumor was modeled under CST Microwave Studio, using Wisconsin Diagnosis Breast Cancer Dataset. Features like the radius, texture, perimeter, area, and smoothness of the tumor are included along with their label data to determine whether the external shape has malignant or benign physiognomies. An explanation of the feasibility of the system deployment and technical recommendations to avoid interference is also described.

전이성 피부 샘암종의 면역조직화학적 고찰 (Metastatic Adenocarcinoma of the Skin - Immunohistochemical Study)

  • 최금하;장규윤
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.1041-1048
    • /
    • 2009
  • The development of skin metastasis is usually a morbid prognostic feature although they occur infrequently. Adenocarcinomas account for up to about 70% of all metastatic skin cancer. In general, adenocarcinomas are the most difficult metastatic tumor to accurately identify the primary site because they don't have distinctive histological features. For this reason, immunohistochemistry have been used to help identify the origin of metastatic adenocarcinomas. This study performed immunohistochemical staining with metastatic adenocarcinomas of the skin using a variety of antisera to find out characteristic immunohistochemical findings of them. This study was made upon the 29 cases of metastatic adenocarcinomas of the skin, which had been confirmed histopathologically in Chonbuk National University Hospital from January, 1986 to April, 2006, Paraffin blocks were colledted and homemade tissue arrays were made. We performed immunohistochemical staning using 12 antibodies (MUC1, 2, 5AC, 6, cytokeratin (CK) 7, 20, thyroid transcription factor-1 (TTF-1), estrogen receptor (ER), progesterone receptor (PR), beta-catenin, cox-2, claudin-1). The mean age at the time of diagnosis was 60.7 years and the male to female ratio was 1.2:1.0. The most common primary site was lung, followed by stomach and colorectum. MUC1 was expressed by most colorectal, breast and lung adenocarcinoma. MUC2 was expressed infrequently. MUCSAC was expressed by most gastric and colorectal cancer MUC6 was not specific of any primary site in this series. CK7+/CK20+immunophenotype was observed in gastric, lung, colorectal adenocarcinoma. CK7+/CK20- immunophenotype was observed in breast, lung, endometrial, uterine cervical, bile duct adenocarcinoma, while CK7-/CK20+ immunophenotype was observed only in colorectal adenocarcinoma. This results show the utility of TTF-1 to confirm the pulmonary origin. On the other hand ER and PR were not useful markers to assess the origin of primary tumor in this series.