Background The number of cosmetic and reconstructive surgeries that use breast implants is increasing in Korea. Recently, it has been reported that breast implant-associated anaplastic large-cell lymphoma is related to textured breast implants, and interest in classification according to the texture of breast implants is increasing. However, there is currently no clear and unified classification. In particular, the definition of "microtextured" is highly varied. In this study, we retrospectively investigated and analyzed the clinical outcomes of smooth and microtextured breast implants. Methods A retrospective chart review of all patients who underwent breast augmentation surgery with smooth and microtextured silicone gel implants between January 2016 and July 2020 was performed. We retrospectively analyzed implant manufacturer, age, body mass index (BMI), smoking status, incision location, implant size, follow-up period, complications, and reoperation rate. Results A total of 266 patients underwent breast augmentation surgery, of which 181 used smooth silicone gel implants and 85 used microtextured silicone gel implants. Age, BMI, smoking status, implant size, and follow-up period were not significantly different between the two groups. Similarly, complications and reoperation rates were not significantly different between the two groups. Conclusion It is important to provide information regarding the clinical risks and benefits of breast implants to surgeons and patients through a clear and unified classification according to the texture of the breast implant.
Mammary implants marketed by Poly Implant Proth$\grave{e}$se (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Proth$\grave{e}$se", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.
Magno-Padron, David A.;Luo, Jessica;Jessop, Terry C.;Garlick, Jared W.;Manum, Joanna S.;Carter, Gentry C.;Agarwal, Jayant P.;Kwok, Alvin C.
Archives of Plastic Surgery
/
제48권4호
/
pp.353-360
/
2021
Background Despite evidence supporting the safety of breast implants, some women associate their implants with adverse health effects and have called this syndrome "breast implant illness." We sought to characterize breast implant illness symptoms and to report how implant removal affects their symptoms. Methods An anonymous 20 question survey was administered to the Facebook group: "UTAH Breast Implant Illness" to characterize the symptoms these women attributed to their breast implants. Several questions allowed us to evaluate how implant removal affected women's symptoms. Results Of the 182 respondents, 97% report that implants negatively affect their health and 95% identify these symptoms with breast implant illness. Ninety-six percent of respondents had implants placed for cosmetic reasons and 51% had silicone implants. The most common symptoms associated with breast implant illness are brain fog (95%), fatigue (92%), joint pain (80%), and hair loss (74%). Sixty percent of respondents learned about breast implant illness from family/friends and/or social media platforms (56%), 40% of respondents had their implants removed, and 97% report relief of their symptoms post-removal (23% complete, 74% partial). Following explantation, there was a significant improvement in all but one reported symptom. An association was found between the number of symptoms reported prior to explantation and the number of symptoms resolving following explantation. Conclusions Breast implant illness is a syndrome characterized by fatigue, decreased focus, hair loss, and joint pain after the placement of breast implants. Nearly all patients report improvement of symptoms after implant removal. Significant efforts should be made to better understand breast implant illness and its etiology.
In this paper, we propose a method to fabricate a patient-specific breast implant using MRI images and 3D scan data. Existing breast implants for breast reconstruction surgery are primarily fabricated products for shaping, and among the limited types of implants, products similar to the patient's breast have been used. In fact, the larger the difference between the shape of the breast and the implant, the more frequent the postoperative side effects and the lower the satisfaction. Previous researches on the fabrication of patient-specific breast implants have used limited information based on only MRI images or on only 3D scan data. In this paper, we propose an algorithm for the fabrication of patient-specific breast implants that combines MRI images with 3D scan data, considering anatomical suitability for external shape, volume, and pectoral muscle. Experimental results show that we can produce precise breast implants using the proposed algorithm.
Background Rupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants. Methods We performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone), duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management. Results Forty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case), microfat graft (2 case), removal only (14 case), and follow-up loss (17 case). Conclusions Saline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.
Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
Archives of Plastic Surgery
/
제41권5호
/
pp.529-534
/
2014
Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.
Background During breast augmentation, the transaxillary approach provides the advantage of allowing the mammary prosthesis to be placed through incisions that are remote from the breast itself, thereby reducing the visibility of postoperative scars. For patients experiencing capsular contracture who do not want additional scars, the previous transaxillary scar can be used for site change and implant exchange. Methods This study analyzed 17 patients (34 breasts) with submuscular breast implants with grade III-IV capsular contracture who received treatment from 2010 to 2015. The mean age of the patients was 29 years (range, 20-38 years). The inclusion criterion was a pinch test of more than 3 cm at the upper pole of the breast. Previous axillary scars were used to expose the pectoralis fascia, and submuscular breast implants were removed carefully. The dissection underneath the pectoralis fascia was performed with endoscopic assistance, using electrocautery under direct visualization. Results The mean follow-up period was 14 months (range, 6-24 months). The entire dissection plane was changed from the submuscular plane to the subfascial plane. Round textured gel implants were used, with a mean implant size of 220 mL (range, 160-300 mL). Two patients developed grade II capsular contracture. There were no cases of malposition or asymmetry. Three patients complained of minor implant palpability. None of the patients required additional surgery. Conclusions Endoscopic subfascial conversion may be an effective technique for treating capsular contracture and avoiding scarring of the breast in selected patients.
Kim, Soo Jung;Song, Seung Yong;Lew, Dae Hyun;Lee, Dong Won
Archives of Plastic Surgery
/
제44권5호
/
pp.413-419
/
2017
Background In breast reconstruction using implants after unilateral mastectomy, it is challenging to create a natural, ptotic contour, and asymmetry is a potential drawback. To achieve breast symmetry and an ideal shape for both breasts, we performed contralateral augmentation in patients undergoing breast reconstruction with implants. Methods Patients underwent unilateral mastectomy and 2-stage reconstruction. During the second stage of the procedure, contralateral augmentation mammoplasty was performed. Preoperatively, we obtained the patients' demographic information, and we then assessed breast volume, the volume and dimensions of the inserted implants, and complications. Breast symmetry was observed by the surgeon and was assessed by measuring the disparity between the final volume of each breast. Results Contralateral augmentation was performed in 52 cases. When compared to patients who did not undergo a contralateral balancing procedure, patients who received contralateral augmentation were younger, thinner, and had smaller breasts. During implant selection for contralateral augmentation, we chose implants that were approximately 1 cm shorter in width, 1 level lower in height, and 1 or 2 levels lower in projection than the implants used for reconstruction. The postoperative breast contours were symmetric and the final volume discrepancy between each breast, which was measured by 3-dimensional scanning, was acceptable. Conclusions We demonstrate that contralateral augmentation can be recommended for patients who perceive their breasts to be small and not beautiful in order to achieve an ideal and beautiful shape for both breasts. Furthermore, this study offers guidelines for selecting the implant that will lead to the optimal aesthetic outcome.
Background Breast augmentation with implants is the most commonly performed cosmetic plastic surgery in Brazil and worldwide. The aim of this study was to assess patient satisfaction and quality of life following subpectoral breast augmentation with either microtextured or macrotextured implants, using the BREAST-Q. Methods A prospective study was conducted with 40 women with hypomastia undergoing subpectoral breast augmentation. The patients were randomly allocated to two groups to receive either microtextured or macrotextured breast implants. All participants were assessed preoperatively (baseline) and after 2 and 4 months of surgery for quality of life and patient satisfaction with the surgical results, using the BREAST-Q augmentation module, a patient-reported outcome measure. Results The patients had a mean age of 28.9 ± 6.45 years. The microtextured (n = 20) and macrotextured (n = 20) groups were homogeneous for sex, age, education level, marital status, and number of children (p > 0.05). Both groups showed significant improvement in satisfaction with breasts (p < 0.001), psychosocial well-being (p < 0.001), and sexual well-being (p < 0.001) at the 2- and 4-month follow-up visits compared with baseline. The observed improvements were associated with high effect size values of 5.09, 3.44, and 3.90, respectively. In contrast, significant decreases from baseline in physical well-being scores (p = 0.001) were found 2 and 4 weeks after surgery in both groups. Conclusion Subpectoral breast augmentation with either microtextured or macrotextured breast implants improved satisfaction with breasts and quality of life in patients with hypomastia.
Ideal results of augmentation mammaplasty consist of symmetry, natural shape, soft feeling and inconspicuous scar. In addition, patient's preferences about size and shape should be included. Static implants could not perfectly satisfy patients' desires for size and shape, but expandable implants enable to change the volume after the operation. From September 2001 to September 2004, 76 patients(150 breasts) underwent breast augmentation using permanent expandable implant. The procedure was unilateral in 2 women and bilateral in 74 women. Age ranged from 19 to 50 years(mean, 29 years). Fifty nine patients underwent simple augmentation mammaplasty, 7 patients were corrected of their severe asymmetry, 2 patients with the congenital breast deformity underwent mammaplasty using this, and 2 patients who had undergone unilateral mastectomy were reconstructed of their breasts using expandable implant. There were no definite complications such as capsular contracture, implant rupture, asymmetry. And there reported little dissatisfaction about the size. The permanent expandable implants might be good alternatives in cases of ordinary breast augmentation as well as tissue deficient patients, asymmetry, congenital anomaly, and breast reconstruction.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.