• Title/Summary/Keyword: Breakthrough time

Search Result 224, Processing Time 0.032 seconds

Studies on the Cation Exchangers from Coals (炭質陽이온交煥體 製造에 關한 硏究)

  • Lee, Bum-Soon;Yoo, In-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.4 no.1
    • /
    • pp.62-66
    • /
    • 1957
  • With the intention of preparing cation exchangers from the domestic coals, and using these for softening hard water and some other purposes, seven kinds of raw coal were tested and the results are as follows. 1) The following conditions of preparation were given the good results. Reaction time 5 hours Reaction temperature $95^{\circ}$ Concentration of sulfuric acid 98% Amount of sulfuric acid 10 times to the sample (as weight) 2) The raw coals which is rich in fixed carbon and have the fuel ratio 0.8 to 1.0 were suitable, and Kampo lignite has shown the best results. 3) The cation exchangers from coals were able to exchange the cation, both hydrogen and sodium type dynamically and statically, like the synthetic ion exchange resin. The exchange capacities were as follows. Total capacity 1.60 meq/g. Breakthrough capacity 1.30 meq/g. Usable breakthrough capacity 1.20 meq/g National Central Research laboratory

  • PDF

Application of Weibull Distribution Function to Analysis of Breakthrough Curves from Push Pull Tracer Test

  • Hyun-Tae, Hwang;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.217-220
    • /
    • 2003
  • In the case of the remediation studies, push pull test is a more time and cost effective mettled than multi-well tracer test. It also gives Just as much or more information than the traditionally used methods. But the data analysis for the hydraulic parameters, there have been some defections such as underestimation of dispersivity, requirement for effective porosity, and calculation of recovery of center of mass to estimate linear velocity. In this research, Weibull distribution function is proposed to estimate the center of mass of breakthrough curve for Push pull test. The hydraulic parameter estimation using Weibull function showed more exact values of center of mass than those of exponential regression for field test data.

  • PDF

Treatment Efficiency of Activated Carbon Adsorption for Dyeing Wastewater Treated by the Different Pre-treatment Methods (염색폐수의 전처리 방법에 따른 활성탄 흡착 처리효율에 관한 연구)

  • Kim Sun-Hee;Lee Sang-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.659-667
    • /
    • 2006
  • This research aims at applicability of adsorption process in order to satisfy the restricted Effluent Quality Standards for dyeing wastewater. The dyeing wastewater treated by biological process with carrier imbedded microorganisms was directly applied to the activated carbon adsorption in Process A, The dyeing wastewater treated by Fenton oxidation for the effluent of biological process was applied to the adsorption in Process B. It was found that the optimum conditions of adsorption with granular activated carbon are $20^{\circ}C$ and 120 minutes for the batch experiment. Langmuir equation was fitted better than Freundlich equation to the experimental data. The breakthrough time of adsorption column was determined by color rather than $COD_{Mn}$ for both Process A and Process B. The results revealed that the breakthrough time of adsorption for two processes was extended by the treatment of Fenton oxidation for dyeing wastewater treated by biological treatment than the direct application of dyeing wastewater treated by the biological treatment. Adsorption process can be applied in order to meet the restricted Effluent Quality Standards for dyeing wastewater.

Adsorption and Thermal Regeneration of Toluene and Benzene on the Fixed Bed Packed with Activated Carbon and Activated Carbon Fiber

  • Kim, Jong-Hwa;Oh, Ok-Kyun;Haam, Seung-Joo;Lee, Chang-Ha;Kim, Woo-Sik
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.44-54
    • /
    • 2001
  • The characteristics of adsorption and desorption of benzene and toluene were investigated at a fixed bed packed with the activated carbon and activated carbon fiber. Through breakthrough experiments under various feed concentration conditions, it was found that the slope of mass transfer zone and the tailing in the breakthrough curves were different from the feed conditions due to different heats of adsorption. In hot nitrogen desorption, the regeneration time and mass transfer zone of the toluene desorption curve were longer than those of the benzene desorption curve because of the difference in adsorption affinity. With an increase in the regeneration temperature, the height of roll-up and the sharpness of desorption curves increased but the regeneration times decreased. The adsorption capacities of the activated carbon and activated carbon fiber after three-time thermal regenerations decreased about 25% and 37% for benzene and 18% and 25% for toluene, respectively. To investigate the effect of the regeneration temperature on the energetic efficiency, the characteristic desorption temperatures of toluene and benzene were investigated by calculating purge gas consumption and temperature.

  • PDF

Prediction of Service Life of a Respirator Cartridge for Organic Solvent by Using Yoon and Nelson's Adsorption Model (Yoon과 Nelson의 흡착모델을 이용한 방독마스크 정화통의 수명예측(I))

  • Kim, Ki-Hwan;Won, Jung-Il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.20-31
    • /
    • 2008
  • A respirator is useful to protect a worker from the harmful gases and vapors in the workplace, and the evaluation of respirator cartridge service life is important for the worker's health and safety. The performance of cartridge is effected by several factors such as concentration of gas and vapor, humidity, temperature, adsorbents and cartridge packing density. Adsorption model was applied to both sampling tube and respirator cartridge to predict the service life for organic vapors. The variables of the adsorption model were measured from the experiment with the sampling tube, and it was used to predict the service life of respirator cartridge. In the experiment, we used carbon tetrachloride as a organic vapor and activated carbon take out respirator cartridge as activated carbon. As a result, it was possible to predict the service life of respirator cartridge and predicted service life was quite correct. Breakthrough time decreased with increase of CCl4 concentration. In case of sampling tube, adsorbed amount of CCl4 was larger than respirator cartridge due to linear velocity. Also, rate constant of sampling tube was larger than respirator cartridge, because of, effect of flow rate, packing density. In the prediction of service life of respirator cartridge by using sampling tube, the time required for 50% contaminant breakthrough(${\tau}$) is more effective than the rate constant(k').

Performance evaluation of membrane bioreactor (MBR) coupled with activated carbon on tannery wastewater treatment

  • Alighardashi, Abolghasem;Pakan, Mahyar;Jamshidi, Shervin;Shariati, Farshid Pajoum
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.517-528
    • /
    • 2017
  • This study evaluates the performance of membrane bioreactor (MBR) coupled with a modified walnut shell granular activated carbon (WSGAC) for tannery wastewater treatment. For this purpose, a pilot with overall volume of 80L and 12 hours hydraulic retention time (HRT) is operated in three scenarios. Here, the chemical oxidation demand (COD) of wastewater is reduced more than 98% in both C:N ratios of 13 (S1) and 6.5 (S2). This performance also remains intact when alkalinity depletes and pH reduces below 6 (S3). The ammonium removal ranges between 99% (S2) and 70% (S3). The reliability of system in different operating conditions is due to high solids retention time and larger flocs formation in MBR. The average breakthrough periods of WSGAC are determined between 15 minutes (S2) and 25 minutes (S1). In this period, the overall nitrate removal of MBR-WSGAC exceeds 95%. It is also realized that adding no chemicals for alkalinity stabilization and consequently pH reduction of MBR effluent (S3) can slightly lengthen the breakthrough from 15 to 20 minutes. Consequently, MBR can successfully remove the organic content of tannery wastewater even in adverse operational conditions and provide proper influent for WSGAC.

Removal of As(III) by Pilot-Scale Filtration System Separately Packed with Iron-Coated Sand and Manganese-Coated Sand (철 및 망간코팅사를 분리 충진시킨 파일럿 여과시스템에 의한 3가 비소 제거)

  • Kim, Kwang-Seob;Song, Ki-Hoon;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.878-883
    • /
    • 2006
  • Removal efficiency of As(III) was investigated with a pilot-scale filtration system packed with an equal amount(each 21.5 kg) of manganese-coated sand(MCS) in the bottom and iron-coated sand(ICS) in the top. Height and diameter of the used column was 200 cm and 15 cm, respectively. The As(III) solution was introduced into the bottom of the filtration system with a peristaltic pump at a speed of $5{\times}10^{-3}$ cm/s over 148 days. Breakthrough of total arsenic in the mid-sampling position(end of the MCS bed) and final-sampling position(end of the ICS bed) was started after 18 and 44 days, respectively, and then showed a complete breakthrough after 148 days. Although the breakthrough of total arsenic in the mid-sampling position was started after 18 days, the concentration of As(III) in this effluent was below 50 ppb up to 61 days. This result indicates that MCS has a sufficient oxidizing capacity to As(III) and can oxidize 92 mg of As(III) with 1 kg of MCS up to 61 days. When a complete breakthrough of total arsenic occurred, the removed total arsenic by MCS was calculated as 79.0 mg with 1 kg MCS. As variation of head loss is small at each sampling position over the entire reaction time, it was possible to operate the filtration system with ICS and MCS for a long time without a significant head loss.

The Effects of Varying Sampling Flow Rates on the Measurements of Total Nitrate and Sulfate in Dry Acid Deposition

  • Park, Jong-Kil;Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.1-12
    • /
    • 2002
  • One technique for determining dry acid deposition fluxes involves measurement of time - averaged ambient concentrations of dry acid deposition species using filter packs (FP) coupled with estimates of mean deposition velocities for the exposure period. A critical problem associated with filter pack data comparisons between various field sampling networks is the use of diverse sampling flow rates and duration protocols. Field experiments were conducted to evaluate the effects of varying sampling flow rates, from 1.5 to 10 standard liters per minute, on total nitrate and sulfate measurements of specific dry acid deposition species . Collocated FP samplers were used to determine sampling and analysis data reproducibility and representativeness . Ambient air samples were simultaneously collected using groups of filter packs operated at various flow rates over identical 7 day periods. The species measured were sulfur dioxide, particulate sulfate , nitric acid and particulate nitrate. Statistical results (ANOVA; alpha level 5%) showed that neither the low nor high sampling flow rates caused a significant difference in the measurements of total sulfate and adjusted total nitrate (ATN) . However, it was concluded that for high flow rate sampling measurements, total nitrate (TN) could be affected during extended sampling durations because of potential nitric acid overloading and breakthrough. Although the previous workers (Costello, 1990; Quillian, 1990) used much higher sampling flow rates (~ 17 sLpm) than employed here, it was assumed that for a high loading (> 50$\mu\textrm{g}$ HNO$_3$) of nitric acid on the Nylon filters, a significant fraction (~10%) of nitric acid could pass through the Nylon filters and be collected on the carbonate impregnated filters. It was concluded that even at the highest sampling flow rate employed (10 sLpm) at the Cary Forest site, nitric acid breakthrough was less than 10% of the total HNO$_3$ collected. However, for a heavily polluted urban airshed or with longer sampling times , higher filter loadings could result in substantial nitric acid breakthrough and HNO$_3$concentrations would be underestimated.

Simultaneous Adsorption Characteristics of Binary-Component Volatile Organic Compounds (2성분계 휘발성유기화합물의 동시 흡착특성)

  • Park, Byung-Bae;Kim, Han-Su;Park, Yeong-Seong
    • Clean Technology
    • /
    • v.7 no.2
    • /
    • pp.133-140
    • /
    • 2001
  • The adsorption characteristics of binary-component Volatile Organic Compounds(VOCs) with benzene and toluene were studied in a fixed bed backed with activated carbon. The adsorption intensites of benzene and toluene resulted from equilibrium adsorption capacity led to roll up phenomenon in a fixed bed and behaved benzene as non-key component which meant the smaller affinity to the activated carbon of the two. From comparion with breakthrough curves between binary-component and single component systems at the same concentration conditions, the stoichiomertic breakthrough time of toluene in both systems had no difference, but that of benzene as non-key component had a tendency to shorten 130min than 200min of single component. In the breakthrough characteristics of binary-component adsorbates, the magnitude of roll-up of the non-key component increased with the increasing of non-key component ratio and aspect ratio(L/D) of fixed bed, while decreased with the increasing of interstitial velocity. Especially, the roll-up phenomenon was more conspicuous with the increasing of mole fraction of key component.

  • PDF

Measurement of mass Transfer Coefficients for Adsorptive Bulk Gas Separation with Velocity Variations (기체속도가 변하는 벌크기체의 흡착공정에서 물질전달계수의 측정)

  • Min, Jun-Ho;Choi, Min-Ho;Suh, Sung-Sup
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.310-318
    • /
    • 1999
  • The concentration breakthrough curves were examined to predict mass transfer coefficients of nitrogen and oxygen in adsorption column for design data of PSA process. Experimental breakthrough curves for bulk gas flow were compared with theoretical simulation results. For quantitative analysis of the adsorption, coupled Langmuir isotherm was considered and LDF model was used to describe the mass transfer effect. In the experimental and theoretical results, it was found that mass transfer coefficient was not affected by flow rate but strongly affected by pressure. As a result of this tendency, mass transfer resistance in this system was proved to belong to the macropore diffusion controlling region and the mass transfer coefficients could be expressed by exponential functions of pressure change. The mass transfer coefficients for one component, nitrogen or oxygen, were successfully applied to breakthrough curves for bulk mixed gases. The experimental curves were reasonably in consistent with the theoretical curves and the error time was less than 5 percent.

  • PDF