초전도 코일 적용으로 인한 DC 차단기의 차단 용량 증대 (Extension of Cut-off Capacity of DC Circuit Breaker due to Superconducting Coil Application)

  • 최혜원;최효상
    • 전기학회논문지
    • /
    • 제68권4호
    • /
    • pp.593-597
    • /
    • 2019
  • We proposed a current Interruption type DC superconducting circuit breaker(I-DC SCB), a protection device that combines the current limiting technology of a superconductor with the cut-off technology of circuit breaker. Unlike existing protective devices, the current I-DC SCB is a device that combines two protection functions, notably improving failure probability and operational reliability. It is also applicable to all DC systems, such as HV, MV, and LVDC, due to the ease in capacity increase. The 100 kV I-DC SCB was designed after taking into account the actual power system conditions, followed by an analysis of the transient characteristics and the breaking range of the limiter. The results of the analysis showed that the I-DC SCB had a fault current limit of about 75% at the rated voltage, and completed the cut-off operation within about 20 ms.

전자기 반발 구동장치를 사용한 고속 차단기 개발 (Development of High Speed Circuit Breaker using Electromagnetic Repulsion Actuator)

  • 황광수;김영일;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.441-448
    • /
    • 2022
  • 배전분야 전력계통에 적용되는 보호기기류는 변전소 차단기, 배전선로의 리클로저, 최소 전류 용량 회로, 고장구간 차단기 등이 있다. 이들은 부분 정전이나 대규모 사고를 방지하고 선로의 순간고장 또는 영구고장 발생 시 정상 계통이 건전성을 유지할 수 있도록 광역 정전 파급을 방지한다. 그러나 사고가 발생할 경우 변전소 차단기와 배전선로 보호기기 간의 보호협조 미비로 인하여 광역 정전을 초래할 수 있다. 더 좋은 전력시스템의 건전성을 확보하기 위하여 1주기(16ms) 이내로 동작하는 차단기를 개발할 필요성이 요구된다. 본 연구에서는 친환경 가스절연 방식의 고속도 차단기를 개발하였으며, IEC 62271-111 표준에 기반한 시험에서 우수한 결과를 얻었다. 이 기기는 고장구간을 정확하고 빠르고 신속하게 분리하여 광역 정전 예방에 기여할 것으로 기대된다.

사무용 빌딩에서의 누전차단기 오동작과 전력품질 분석 (Failure of Earth Leakage Breaker and Power Quality Analysis in Office Buildings)

  • 이상익;유재근;정종욱;임용배;전정채
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.211-216
    • /
    • 2004
  • This paper presented a actual conditions on a false-tripping of ELB(Electrical Leakage Breaker) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, printers, fax machines, and test equipments in several office buildings. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of in office buildings. Also, power quality measurements such as harmonic currents, voltage and current waveforms and current imbalance were made at various office buildings where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating md tripping characteristics test of ELB when subjected to distorted current waveforms.

  • PDF

전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load)

  • 이상호;오홍석
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF

수변전설비에서 접점 불량에 따른 열 및 전계 분포 해석 (The Analysis of Temperature and Electric Field due to Contact Failure in Power Substation)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.307-311
    • /
    • 2016
  • Although there are existing Residual Current Protective Device (RCD) including detect electric leakage and elements such as short circuit and surge, the occurrence of incidents caused by electric faults, including fire, are still constant. The purpose of this study is to analyze the causes of accidents through the electric field distribution in the interpretation of the fault contact breaker. Simulation results by the arc fault has shown the convergence of temperature and electric field to the defect. Through their simulation results, the main cause of erosion phenomena in circuit breaker bar is the electric arc by concentration of electric field not due to dissolve by temperature.

IEC 표준에 의한 고장전류 계산과 보호협조 (Fault Current Calculation and Coordination by IEC Standards)

  • 손석금
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

축사 규모별 누전성분 특성 분석 (Analysis of Characteristic for Electric Leakage Component at Stable Size)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.

유한요소법을 이용한 유압브레이커 Cylinder와 Piston의 열-구조 연성해석을 통한 안정성 평가 (Assessment of Stability of Stability of Hydraulic Breaker Cylinder and Piston through Thermal-Structural coupled Field Analysis by Finite Element Method)

  • 임동욱;박윤수;신봉철
    • Design & Manufacturing
    • /
    • 제12권1호
    • /
    • pp.41-46
    • /
    • 2018
  • This study proves the causes of cylinder and piston jam by scratches which is the fatal problem of hydraulic breaker through the thermal analysis and thermal-structural coupled field analysis. The trouble from the scratch is a complex problem which can be caused by manufacturing process (this is an internal factor) and the users mistake or contamination in the hydraulic circuit (these are an external factor). Hence, it's not easy to investigate the causes, also hard to prevent the recurrence. In this reason, hydraulic breaker manufacturers are trying to improve the manufacturing process such as machining, heat treatment, grinding, cleaning, also to prevent the contamination in hydraulic circuit and to remove the remains. It's being managed thoroughly by manufacturers. This study shows the effect of the temperature rise by the frictional heat generated when the piston hits the tool on the hydraulic oil while the hydraulic breaker is operating, also the temperature distribution when it starts to affect main components of hydraulic breaker. The stress and the amount of deformation also could be found through thermal-structural coupled field analysis. It proved that the stress and deformation are proportionally increased according to the temperature rise in hit area, and it affects the cylinder and the viscosity of hydraulic oil inside the cylinder when it heats up beyond the certain temperature.

차단키 실패 보호 IED의 IEC 61850 시스템 성능 시험 절차서에 관한 연구 (Study on IEC 61850 Performance Testing Procedures of BF Protection IED)

  • 이남호;장병태
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.59-66
    • /
    • 2008
  • 디지털 기술 기반의 차세대 변전시스템의 시스템 성능 검증을 위해 변전소 전력설비의 보호에 있어 가장 중요한 보호요소 중 하나인 차단기 실패 보호 IED를 대상으로 하는 IEC 61850 시스템 성능 시험 절차서를 구현하였다. 디지털 변전소에 대한 통신규격이 단일화되고 시스템이 디지털화됨에 따라 IED들은 상호 통신이 가능해지게 되었으며, 따라서 단일 IED의 전기 접점을 통해 이루어지던 예전의 시험방식에서 네트워크를 통한 시스템 차원의 시험방식으로 변화가 필요하게 되었다. 본 논문에서는 차단기 실패 보호 IED를 시스템적으로 시험할 수 있도록 UML을 이용한 성능시험절차서의 구현내용을 보여주고자 한다.

에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로 (Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.