• Title/Summary/Keyword: Breakdown strength

Search Result 522, Processing Time 0.031 seconds

Properties of Electrical Breakdown in the Interface between XLPE / EPDM (XLPE/EPDM 계면에서의 절연파괴 특성)

  • Jo, J.H.;Han, S.K.;Lee, C.J.;Kim, S.K.;Choi, Y.S.;Park, K.S.;Suh, K.S.;Park, D.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1469-1471
    • /
    • 1996
  • In this paper, We intended to evaluate the characteristics of XLPE/EPDM interface which exists in the cable joint. The fault of practical cable was mainly occurred in this interface. Thus we looked into the electrical characteristics through the conduction current and the breakdown test. Through the experiment, we obtained the result that the conduction current in this interface flowed less than other dielectric materials, that the breakdown strength was higher and that the pressure dependance of the breakdown strength was higher.

  • PDF

AC Breakdown Property of Nano-$TiO_2$ and Micro-Silica filler Mixture of Epoxy Based Composites

  • Heo, J.;Jung, E.H.;Lim, K.J.;Kang, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.150-150
    • /
    • 2009
  • In this paper, various kinds of epoxy based nanocomposites were made and AC breakdown properties of nano-$TiO_2$ and micro-silica filler mixture of epoxy based composites were studied by sphere to sphere electrode. Moreover, nano- and micro-filler combinations were adopted as an approach toward practical application of nanocomposite insulating materials. AC breakdown test was performed at room temperature $(25^{\circ}C)$, $80^{\circ}C$ and $100^{\circ}C$. The result shows breakdown strength about non-filled, nano-scale $TiO_2$, micro-scale silica and nano-$TiO_2$, micro-silica filled epoxy composites.

  • PDF

A study on the discharge characteristics of liquid nitrogen using at cryogenic cable (극저온 전력케이블을 액체질소에 대한 방전특성에 관한 연구)

  • 이현동;주재현;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.125-129
    • /
    • 1996
  • This study describes that electrical breakdown of liquid nitrogen which is influenced with bubble has been investigated as liquid nitrogen is used coolant of high temperature(T/sub c/) superconductivity. In order to investigate breakdown of liquid nitrogen, we formed electrode system of parallel and vertical configuration toward gravitutional direction. In case of changing with electrode configuration of equal electrode and gap spacing in uniform and nonuniform electric field bubble behavior is changed. In result of that, breakdown voltage is changed. Therefore, this study proved that electrode configuration must be formed the smallest existing probability of bubble between two electrodes in order to increase breakdown strength of liquid nitrogen at atmosphere pressure.

  • PDF

Breakdown Characteristics of LLDPE/EVA mixture film under DC field (직류 전계하 LLDPE/EVA혼합필름의 절연파괴특성)

  • 고시현;김형주;이종필;신현택;이충호;홍진웅
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.65-68
    • /
    • 2000
  • Polyethylene, has long history and is widely used, was researched due to good electrical properties by many authors. But PE under stress has the critical defects of space charge accumulation and tree growth, so various methods such as catalyst, additives and blend to improve these problems have been execute, of which we selected blending method. As in our previous papers we investigated electrical conduction, dielectric and AC dielectric breakdown characteristics, we did DC dielectric breakdown characteristics in this paper. We selected pure LLDPE, pure EVA and LLDPE films mixed with EVA as specimens, which were mixed with the weight percentages of 50, 60, 70 and 80[wt%] to be thin film. DC applying voltage speed was 500[V/sec]. The relation between dielectric breakdown characteristics and the variations of super structure due to mixing was investigated, and especially trap level at amorphous region, threshold energy increment of conductive electron at free volume were considered.

  • PDF

A study on analysis of interfacial breakdown properties with variable temperalure in straight cable Joint modeling EPGXY/EPOM interface (온도에 따른 케이블 직선 접속재 모델링 EPOXY/EPDM 계면의 파괴 특성에 관한 연구)

  • 배덕권;정인재;김상걸;정일형;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.532-535
    • /
    • 1999
  • In power cable joints, the interfaces of two different dielectric materials are inevitable. In addition, the interfacial breakdown between two internal dielectric surfaces represents one of the major causes of failure for power cable joints. We chose epoxy/EPDM interface, one of the interface in cable joints, and investigate dielectric interfacial breakdown phenomenon. First, design specimen with Flux 2D. Second, find interface condition which has high dielectric strength. Third, investigate interfacial breakdown properties with variable temperature.

  • PDF

A Study on the Breakdown Characteristics in Cross-linked Polyethylene by Treeing Effect (가교폴리에틸렌의 내부방전효과에 의한 절연파괴특성)

  • 곽영순;이양성;조정수
    • 전기의세계
    • /
    • v.27 no.6
    • /
    • pp.76-83
    • /
    • 1978
  • This paper reveals the results of fundamental experiments with the breakdown strength- and treeing phenomena, by A.C voltage and impulse voltage, of cross-linked polyethylene insulator, respectively compared in each case of the various specimens; nonvoid, air void, water void, oil void and oil impregnated one, all articially made. In this research, the V-t and V-n characteristics are investigated by means of the Weibull distribution and are analysed the characteristics of fatigue breakdown caused by the A.C and impulse voltage. Based on numerous tests, treeing effect and treeing breakdown mechanism is investigated through microscopic photographs taken to clarify the shapes of each tree and treeing breakdown phenomena.

  • PDF

Breakdown Characteristics of a Vertical Sphere-Plane Air Gap in the Presence of Combustion Flame (수직배치 구대평판 공기 갭에서 연소화염 존재시의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, breakdown characteristics of a vertical sphere-plane air gap in the presence of combustion flame were examined under the application of a.c. and d.c. high-voltages in order to investigate the effect of flame on the dielectric strength of air. Propane gas is used as the fuel of the flame, and the temperature distribution of air around the flame is measured. The polarity effects for the d.c. voltages and breakdown voltages of air when applied both of a.c. and d.c. voltages were examined in the case of the variation of the gap length and the horizontal distance between the flame and the high-voltage sphere electrode. The influence of relative air density, electrification and shape changes of the flame as factors that affect the breakdown voltages were discussed.

Influence of Surface Shape on Particle-initiated Breakdown in $SF_6$ Gas ($SF_6$ 가스중의 연면형상이 입자오손 파괴 전압에 미치는 영향)

  • Lee, Hyeong-Ho;Kim, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.645-647
    • /
    • 1993
  • Surface breakdown characteristics are investigated under metallic-particle contaminated conditions in $SF_6$ gas. The main results show that a rib increases breakdown voltage by a corona stabilization effect and the elongation of discharge path. The breakdown voltage at higher pressures than 4 atm may be estimated on the basis of mean breakdown field strength($E_{BD}$) and discharge length(L) which depend on gas pressure and surface shape.

  • PDF

Thermal, Electrical Properties for Epoxy/Microsilica/Nanosilica Composites (에폭시/마이크로실리카/나노실리카 혼합 콤포지트의 열적, 전기적 특성)

  • Kang, Geun-Bae;Kwon, Soon-Seok;Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.779-785
    • /
    • 2012
  • The epoxy/micro-and nano-mixed silica composites(EMNC) systems were prepared and the AC insulation breakdown strength was evaluated. Glass transition temperature (Tg) and crosslink density were also measured by dynamic mechanical analyzer(DMA) in order to correlate them with the electrical and mechanical properties, and the effect of silane coupling agent on the electrical properties was also studied. Electrical properties and crosslink density of epoxy/micro-silica composite were noticeably improved by addition of nano-silica and silane coupling agent, and the highest breakdown strength was obtained by addition of 0.5~5 phr of nano-silica and 2.5 phr of silane coupling agent, and the highest tensile and flexural strength were obtained by addition of 2.5 phr of nano-silica.

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.