• 제목/요약/키워드: Breakdown & repair

Search Result 54, Processing Time 0.026 seconds

A Study on the Construction Specification and Quality Assurance Criteria in Clay Paver (점토바닥벽돌의 품질 및 시공기준 연구)

  • Park, Dae-Gun;Lee, Sang-Yum;Kim, Kyoon-Tai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.6
    • /
    • pp.111-121
    • /
    • 2010
  • As the customer's interest for sidewalk block in the street or apartment complex is increasing, the materials of block which had been a concrete block exclusively are varied to clay paver, native rock and wood etc. Especially, the sales volume of clay paver which is environment-friendly and ergonomic is dramatically increasing every year with two digits growth rate, however, many problems like "Edge Cracking" "Freezing Breakage" "Bending Breakage" "Joint Gap" are happening frequently within a couple of hours after installation due to the durabilities. Because of the characteristics of Ceramic products, clay pavers are very easy to be broken when they are bumped against each other. In addition, they are relatively fragile by a freezing expansion breakage when exposed to water due to hydrophilic property as well as the intensity and absorptance of the products are varied with small difference from the production process such as production equipment and process control. Therefore, it costs a lot of money to repair the breakdown unless production and installation is carried out according to the strict criteria of the quality control. In this study, the symptoms of breakdown frequently happened in clay paver are classified by each type and finally the solution for this problem in the production of brick, installation and criteria of quality control through compressive strength and absorptance test is suggested.

A Study on the Life Cycle Cost Analysis of Light Railroad Transit Bridges (경량전철 교량의 생애주기비용 분석에 관한 연구)

  • Lee, Du-Heon;Kim, Kyoon-Tai;An, Dong-Geun;Jun, Jin-Taek;Han, Choong-Hee
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.384-389
    • /
    • 2006
  • The needs for Light Railroad Transit(LRT) have been increased due to the heavy traffic congestions in large cities like Seoul, Korea. Korean government is seeking the LRT system development (including planning, designing, construction, and maintenance and operations) in terms of public-private-partnership (PPP). At the private sector side, it is crucial to estimate the life cycle cost (LCC) to project the cash flow during the O&M period. Since the most construction and O&M cost of LRT project is at the bridge construction, a cost analysis model and a cost breakdown structures (CBS) on LRT bridges are discussed through in depth literature reviews. Construction and maintenance cost of bridges are collected and analyzed. LCC is analyzed by types of bridge superstructures and historical data of repair and rehabilitation (R&R) is investigated. There have been scarce number of LCC analysis on railway bridges. This research delivers a well-defined CBS and maintenance cost data, which will be a great benefit to the systematic maintenance strategy development for railroad bridges.

  • PDF

Breakdown Structure and Weight Evaluation for Maintenance Items of Public Childcare Facilities (국·공립 보육시설의 운영유지 항목 분류체계 개발 및 중요도 산정)

  • Park, Hyeong-Jin;Park, In-Ji;Moon, Hyun-Seok;Koo, Kyo-Jin;Hyun, Chang-Taek
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.2
    • /
    • pp.3-11
    • /
    • 2013
  • Recently according to increasement of the single family and dual-earner couples, the number of infants and young children stays on a long time to the childcare facilities. this is increasing the importance to improve the physical environment. However, the operating and maintenance costs of the national-public childcare facilities have taken effect of the unfair support issues of municipality's financial situation. Especially, because of the lack of the operating and maintenance costs of the facility and the shortage of facilities equipment maintenance repair costs, nursery operations and Maintenance items are needed to distribute appropriately. Therefore, this study is to estimate the importance to facility operations and maintenance items based on "Kindergarten and Childcare Facilities"presented at the Child Care Policy Study. we are expected to allocate appropriately of operation and maintenance cost of a limited budget. In particular, those can be considered for operation and maintenance cost about the National-Public Childcare Facilities and be determined to a safe and pleasant environment to kindergartens through the appropriate operations and maintenance support.

Environmental Impact Assessment within Regional and Municipal Planning (지역 및 도시계획에서의 환경영향평가)

  • Socher, Wolfgang
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.3
    • /
    • pp.27-29
    • /
    • 1995
  • Within regional and municipal planning we are using several levels or types of EIA in the city of Dresden. Some of these types, practical aspects and some experiences of our work will be presented in this contribution. Firstly I may introduce you to some general conditions for your better understanding of our principles of work. Surely you know about. the destruction of the political and economical structures in Eastern Germany since 1989. Until today our not quite simple task is to build up new ones. At the same time people were in great expectation of freedom and high standard of living as soon as possible. Economical difficulties increased in association with the breakdown of the market in Eastern Europe. How to rebuild industrial estatements and how to renew the traffic systems? We had to find answers to all these complex question. Should we only repair the former damages or could we reach a really environmental sound production for the future? The demand for a rapid economic growth is an incredible challenge for the application of new environmental ideas. I am truly not sure whether you know the city of Dresden or not. So I would like to give you a short introduction. Dresden is situated in a valley shaped by the river Elbe. There live about 500,000 people. Dresden has a great reputation for arts and sciences. Its also well know as a town of high technology industries such as electronics and optics. We restored the power plant and therefore we don't need any atomic power plants actually we haven't got one. Since 1990 there were founded many official agencies in Dresden because it is the capatal of Saxony. Considering nature and environment we there is a large forest area called "Dresdner Heide". The river Elbe and the meadows are situated on both sides of the river. There are a lot of green and free places in the city area too. Furtheron there is something unusual for a large city: about 50% of the drinking water resources mostly take place within the city itself. The origin is the ground water as well as water from the river Elbe after filtration of course.

  • PDF

Acoustic Emission Monitoring of Incipient in Journal Bearings - Part I : Detectability and measurement for bearing damages (음향방출을 이용한 저어널 베어링의 조기파손감지(I) - 베어링 손상 형태별 감지능력 및 측정기술 -)

  • Yoon, Dong-Jin;Kwon, Oh-Yang;Chung, Min-Hwa;Kim, Kyung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.1
    • /
    • pp.16-22
    • /
    • 1994
  • In contrast to the machineries using rolling element bearings, systems with journal bearings generally operate in large scale and under severe loading condition such as steam generator turbines and internal combustion engines. Failure of the bearings in these machineries can result in the system breakdown. To avoid the time consuming repair and considerable economic loss, the detection of incipient failure in journal bearings becomes very important. In this experimental approach, acoustic emission monitoring is applied to the detection of incipient failure caused by several types of abnormal operating condition most probable in the journal bearing systems. It has been known that the intervention of foreign materials, insufficient lubrication and misassembly etc. are principal factors to cause bearing failure and distress. The experiment was conducted under such designed conditions as hard particles in the lubrication layer, insufficient lubrication, and metallic contact in the simulated journal bearing system. The results showed that acoustic emission could be an effective tool to detect the incipient failure in journal bearings.

  • PDF

Chk2 Regulates Cell Cycle Progression during Mouse Oocyte Maturation and Early Embryo Development

  • Dai, Xiao-Xin;Duan, Xing;Liu, Hong-Lin;Cui, Xiang-Shun;Kim, Nam-Hyung;Sun, Shao-Chen
    • Molecules and Cells
    • /
    • v.37 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • As a tumor suppressor homologue during mitosis, Chk2 is involved in replication checkpoints, DNA repair, and cell cycle arrest, although its functions during mouse oocyte meiosis and early embryo development remain uncertain. We investigated the functions of Chk2 during mouse oocyte maturation and early embryo development. Chk2 exhibited a dynamic localization pattern; Chk2 expression was restricted to germinal vesicles at the germinal vesicle (GV) stage, was associated with centromeres at pro-metaphase I (Pro-MI), and localized to spindle poles at metaphase I (MI). Disrupting Chk2 activity resulted in cell cycle progression defects. First, inhibitor-treated oocytes were arrested at the GV stage and failed to undergo germinal vesicle breakdown (GVBD); this could be rescued after Chk2 inhibition release. Second, Chk2 inhibition after oocyte GVBD caused MI arrest. Third, the first cleavage of early embryo development was disrupted by Chk2 inhibition. Additionally, in inhibitor-treated oocytes, checkpoint protein Bub3 expression was consistently localized at centromeres at the MI stage, which indicated that the spindle assembly checkpoint (SAC) was activated. Moreover, disrupting Chk2 activity in oocytes caused severe chromosome misalignments and spindle disruption. In inhibitor-treated oocytes, centrosome protein ${\gamma}$-tubulin and Polo-like kinase 1 (Plk1) were dissociated from spindle poles. These results indicated that Chk2 regulated cell cycle progression and spindle assembly during mouse oocyte maturation and early embryo development.

Determination of Maintenance Period and Failure Probability for Turbine Using Maintenance Record (터빈설비의 정비이력을 이용한 고장확률 예측 및 정비주기 설정에의 응용)

  • Song, Gee-Wook;Koo, Jae-Raeyang;Choi, Woo-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1325-1330
    • /
    • 2010
  • The breakdown of any critical component of a turbine results in the outage of power plants. Unexpected failure decreases equipment utilization and causes enormous economic losses. Currently, we conduct conservative preventive maintenance for a maintenance period that is proposed by a vendor. In the rapidly changing business environment, reliability-based maintenance is required in order to remain competitive and reduce maintenance costs while maintaining the reliability of equipment. In order to determine an appropriate maintenance period for guaranteeing reliability, we must determine the failure probability by carefully analyzing the failure history of the equipment. In this study, we created a database of failure history for power-plant turbines, predicted the best repair time using the Weibull function, and investigated how the appropriate maintenance cycle can be determined.

Optimal Inspection Policy for One-Shot Systems Considering Reliability Goal (목표 신뢰도를 고려한 원-샷 시스템의 최적검사정책)

  • Jeong, Seung-Woo;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.4
    • /
    • pp.96-104
    • /
    • 2017
  • A one-shot system (device) refers to a system that is stored for a long period of time and is then disposed of after a single mission because it is accompanied by a chemical reaction or physical destruction when it operates, such as shells, munitions in a defense weapon system and automobile airbags. Because these systems are primarily related with safety and life, it is required to maintain a high level of storage reliability. Storage reliability is the probability that the system will operate at a particular point in time after storage. Since the stored one-shot system can be confirmed only through inspection, periodic inspection and maintenance should be performed to maintain a high level of storage reliability. Since the one-shot system is characterized by a large loss in the event of a failure, it is necessary to determine an appropriate inspection period to maintain the storage reliability above the reliability goal. In this study, we propose an optimal inspection policy that minimizes the total cost while exceeding the reliability goal that the storage reliability is set in advance for the one-shot system in which periodic inspections are performed. We assume that the failure time is the Weibull distribution. And the cost model is presented considering the existing storage reliability model by Martinez and Kim et al. The cost components to be included in the cost model are the cost of inspection $c_1$, the cost of loss per unit time between failure and detection $c_2$, the cost of minimum repair of the detected breakdown of units $c_3$, and the overhaul cost $c_4$ of $R_s{\leq}R_g$. And in this paper, we will determine the optimal inspection policy to find the inspection period and number of tests that minimize the expected cost per unit time from the finite lifetime to the overhaul. Compare them through numerical examples.

A Study on Dual System for Fault Tolerance of PLC (PLC 오류를 포용하는 이중화 시스템에 관한 연구)

  • Ko, Jae-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.3
    • /
    • pp.397-404
    • /
    • 2011
  • In this research, wish to suggest method to embody system that can accommodate defect of PLC and find actual propriety. Defect permission control system minimizes production damage because enables repair and checking without discontinuance and improve believability about whole system. Propose duplexing of system to embody this fault tolerant system. Therefore, composed control system that can permit defect or breakdown duplexings of various module proposing this system, and confirms to simulation and actuality kiln of defect permission control system through an application experiment, and compares for mean time between defect by estimate and defect special quality and system configuration of failure(failure) to improve believability of PLC control system together. In proposed system expression method and system mode and relation with operation mode, error discovery mode and switching tube of duplexing mode, and PLC's central processing unit of node study algorithm about master-standby conversion driving and continuous operation of 2 channels method that have 2 that is not one and deduced continuous operation method and result about defect permission in this algorithm and applies this result to actuality kiln control system and confirms continuous operation about PLC defect permission.

Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System (180kV HVDC 해저케이블 기계적/전기적 특성 평가)

  • Kim, N.Y.;Lee, T.H.;Lee, S.J.;Ji, B.K.;Kim, J.N.;Jeon, S.I.;Yun, H.S.;Joung, S.K.;Kang, C.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF