• Title/Summary/Keyword: Break-In

Search Result 3,247, Processing Time 0.056 seconds

Thermal Fluid Mixing Behavior during Medium Break LOCA in Evaluation of Pressurized Thermal Shock

  • Jung, Jae-Won;Bang, Young-Seok;Seul, Kwang-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.635-640
    • /
    • 1998
  • Thermal fluid mixing behavior during a postulated medium-size hot leg break loss of coolant accident is analyzed for the international comparative assessment study on pressurized thermal shock (PTS-ICAS) proposed by OECD-NEA. The applicability of RELAP5 code to analyze thermal fluid mixing behavior is evaluated through a simple modeling relevant to the problem constraints. Based on the calculation result, the onset of Thermal stratification is investigated using Theofanous's empirical correlation. Sensitivity calculations using a fine node model and crossflow model are also performed to evaluate the modeling capability on multi-dimensional characteristics related to thermal fluid mixing.

  • PDF

Numerical Simulation of the Floodwave Analysis Resulting from Dam Failure - Flood on Dry Bed from Instantaneous Dam-Break- (댐의 파괴형태와 하도부 양상에 따른 홍수파의 전달특성 해석에 관한 연구 - 급격한 댐 파괴와 마른하도를 중심으로 -)

  • 한건윤
    • Water for future
    • /
    • v.23 no.4
    • /
    • pp.467-476
    • /
    • 1990
  • Numerical model for the floodwave propagation on dry bed which is resulting from the instantaneous failure of a dam has been developed by moving Hartree scheme. The numerical simulation result of the model has good agreements with the observed data by WES in terms of stage hydrograph and characteristics profiled. The model would contribute effectively to forecast the flood on dry bed resulting from instantaneous dam-break.

  • PDF

A Study on electrical Characteristics of XLPE by additives (첨가제에 의한 전력 cable용 XLPE의 전기적 특성에 관한 연구)

  • 김규식;손원근;임기조;박수길
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.61-64
    • /
    • 2000
  • Three kinds of treeing inhibitors are added to investigate the effect on electrical properties of XLPE. The treeing inhibitors are barbituric acid, 4- (4-Nitrophenylazo) resorcinol and 4-(4-Nitrophenylazo) naphthol. Added amount of each treeing inhibitors varied form 0phr to 2.0phr. In order to know the changes of electrical properties, break down strength, tan$\delta$, and $\varepsilon$$_{r}$ were measured. Experimental results showed that electrical properties of each sample was slightly changed by amount of additives.s.

  • PDF

A study on dielectric characteristics of gamma irradiated LDPE (방사선 조사에 따른 저밀도 폴리에틸렌의 유전특성에 관한 연구)

  • kim, Ki-Yup;Lee, Chung;Lim, Kee-Joe;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.169-172
    • /
    • 2000
  • In this paper, we evaluated the mechanical and dielectric properties of LDPE depend on $Co_{60}$${\gamma}$-irradiation doses. The chemical analyses for FT-IR, gel content, the mechanical properties for elongation at break and the dielectric parameters for permittivity, tan$\delta$ were discussed as a function of irradiation doses. Test result presented that elongation at break of irradiated LDPE was inversely proportional to gel content. For dielectric analyses, permittivity showed a salient characteristic for various irradiation doses, it was related to polar groups caused radiation degradation and tan$\delta$ of irradiated LDPE increased with irradiation doses.

  • PDF

Efficiency appraisal of 22.9kV tree retardant power cable (22.9kV 트리억제형 전력케이블의 성능평가)

  • Kim, We-Young;Yun, Dae-Hyuk;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.179-182
    • /
    • 2002
  • XLPE compound have used for insulation of 22.9(kV) power cable. But tree retardant power cable has developed and is going to br used commonly. TR XLPE compound retard production and growth of water tree. In this paper, tensile strength, elongation at break, degree of crosslinking, lightning impulse test, AC breakdown test, cyclic aging for 14days and accelerated water treeing test of TR XLPE insulated power cable were examined according to the KEPCO buying spec. & AEIC CS 5-94 standards. before and after As the result, tensile strength, elongation at break and degree of crosslinking test results of TR XLPE insulation were higher than requirement values. After accelerated water treeing test for 120 days, 240 days and 360 days, AC breakdown voltages were not decreased for accelerated water treeing aging duration

  • PDF

Prediction of Loss of Life in Downstream due to Dam Break Flood (댐 붕괴 홍수로 인한 하류부 인명피해 예측)

  • Lee, Jae Young;Lee, Jong Seok;Kim, Ki Young
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.879-889
    • /
    • 2014
  • In this study, to estimate loss of life considered flood characteristics using the relationship derived from analysis of historical dam break cases and the factors determining loss of life, the loss of life module applying in LIFESim and loss of life estimation by means of a mortality function were suggested and applicability for domestic dam watershed was examined. The flood characteristics, such as water depth, flow velocity and arrival time were simulated by FLDWAV model and flood risk area were predicted by using inundation depth. Based on this, the effects of warning, evacuation and shelter were considered to estimate the number of people exposed to the flood. In order to estimate fatality rates based on the exposed population, flood hazard zone is assigned to three different zones. Then, total fatality numbers were predicted after determining lethality or mortality function for each zone. In the future, the prediction of loss of life due to dam break floods will quantitatively evaluate flood risk and employ to establish flood mitigation measures at downstream applying probabilistic flood scenarios.

The Relation between Pullout Load and Compressive Strength of Ultra-High-Strength Concrete (초고강도 콘크리트의 인발하중과 압축강도와의 관계)

  • Ko, Hune-Beom;Kim, Ki-Tae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • The pullout test, a nondestructive testing(NDT), for pre-installed inserts is perhaps the most widely used technique to estimate the in-situ compressive strength of concrete. It measures the force needed to pullout a standardized metal insert embedded into concrete members. The pullout test was certified by the American Society for Testing and Materials(ASTM) and Canadian Standards Association(CSA) as a reliable method for determining the strength of concrete in concrete structures under construction. To easily estimate the strength of ultra-high-strength concrete, a simplified pullout tester, primarily composed of a standard 12mm bolt with a groove on the shaft as a break-off bolt, an insert nut, and a hydraulic oil pump without a load cell, was proposed. Four wall and two slab specimens were tested for two levels of concrete strength, 80MPa and 100MPa, using a simplified pullout tester with a load cell to verify the advantages of the pullout test and simplified pullout test. The compressive strength of concrete, pullout load, and the rupture of the break-off bolt were measured 11 times, day 1 to 7, 14, 21, 28, and 90. The correlation of the pullout load and the compressive strength of each specimen show a higher degree of reliability. Therefore, a simplified pullout test can be used to evaluate the in-place strength of ultra-high-strength concrete in structures. The prediction equation for the groove diameter of the break-off bolt(y) with the concrete strength(x) was proposed as y=0.0184x+5.4. The results described in this research confirm the simplified pullout's utility and potential for low cost, simplicity, and convenience.

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

A Study on the Confidence of Dry Eye Diagnosis Methods (건성안 검사 방법의 신뢰도에 대한 연구)

  • Lee, Byeong Jun;Hong, Jae Hyeon;Jung, Dai;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • Purpose: To study on the confidence of dry eye diagnosis methods which need to prescribe contact lens. Methods: Non-invasive tear film break-up time (NIBUT) and tear film break-up time (TBUT) were measured in forty healthy subjects in their 20s, and then the subjects were classified into normal eye and dry eye. The results of McMonnies questionnaire, tear prism height measurement, Hardtack test, blink rate measurement and Schirmer test were compared with the results of NIBUT and TBUT. Results: The results of NIBUT and TBUT were as follows; 20 subjects had normal eyes, 10 subjects had dry eyes in both NIBUT and TBUT, and 10 subjects showed different results. In McMonnies questionnaire, the score of normal eye group averaged 8.2 and that of dry eye group averaged 18.5, which showed statistically significant difference. Furthermore, 100% of normal eye group classified by the results of NIBUT and TBUT corresponded with the result of McMonnies questionnaire and 90% of dry eye group showed the correspondence. Tear prism height of normal eye group averaged 0.32 mm and that of dry eye group averaged 0.23 mm, which were significantly different. Hardtack test, blink rate measurement and Schirmer test without local anesthesia showed no statistically significant difference between normal eye group and dry eye group. Conclusions: On dry eye diagnosis methods, the results of McMonnies questionnaire and tear prism height measurement had close correlation with the results of NIBUT and TBUT.

  • PDF

Effect of night break treatment using Red LED (660 nm) on flower bud initiation and growth characteristics of chrysanthemum cv. 'Baekma', and cv. 'Jinba' (적색 LED(660nm)의 광중단 처리에 따른 국화 '백마'와 '신마'의 화아분화 및 생육특성)

  • Kwon, Young Soon;Choi, Seong Youl;Kil, Mi Jung;You, Bong Sik;Jung, Jae A;Park, Sang Kun
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.297-303
    • /
    • 2013
  • This study was carried out to examine the effect of Red LED (660 nm) and fluorescent lamp for night break (NB) treatments of each 3 hours (22:30-01:30), 4 hours (22:00-02:00) and 5 hours (21:30-:02:30) per day for 53 days on flower bud initiation and growth in Chrysanthemum cv. 'Baekma' and cv. 'Jinba'. The days to flower budding after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (21.0 days) and 5 hr (20.5 days) NB, and it was shorter at Red LED 3 hr (14.2 days). The days to flowering after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (54.0 days), 5 hr (53.5 days) NB, and Red LED 5 hr (53.3 days), and it was shortest at Red LED 3 hr (50.2 days) NB treatment among all treatments. The days to flower budding after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (20.6 days) and was shorter at Red LED 3 hr (14.1 days) among all treatments. Similarly, the days to flowering after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (55.3 days) and was shortest at Red LED 3 hr (50.2 days) among all treatments. Therefore, inhibition of flower bud initiation was the most effective under fluorescent lamp 4 hr treatment. The length of cut flower of 'Baekma' was increased by fluorescent lamp 4 hr, 5 hr, and Red LED 5 hr, but of 'Jinba' was longer at LED 4 hr and 5 hr treatment. The weight of cut flower of 'Baekma' was heaviest at fluorescent lamp 5 hr treatment and was at Red LED 5hr treatment for 'Jinba' even though there was not statistically significant difference between 'Baekma' and 'Jinba'. Consequently, under fluorescent lamp 4 hr for night break was the most effective on flower bud initiation, flowering inhibition and cut-flower characteristics in 'Baekma' and 'Jinba'.