• 제목/요약/키워드: Break test

Search Result 556, Processing Time 0.03 seconds

Study of Production and Material Properties of Micro Screw Using SWCH18A and SUS XM7 Materials (SWCH18A 와 SUS XM7 을 적용한 초소형 나사제작 및 물성분석에 관한 연구)

  • Ra, Seung-Woo;Kim, In-Rak;Hwang, Sung Tack
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.1043-1048
    • /
    • 2014
  • As micro screws feature reduced screw lengths and pitches, the resulting clamping force diminishes because of the reduced length of the actual joints. The elements of the clamping force are material, geometry, and friction. We studied the shrinking size of the screw and the methods to improve the clamping force by changing the material. We developed a micro screw using SWCH18A and SUS XM7 materials, and obtained the precision and thickness of the pitch through three-dimensional measurement. We also measured the external resistance of the micro screw by applying the Vicker's hardness test and conducted a break surface analysis using a break torque test and SEM for obtaining the break characteristics.

Effect of critical flow model in MARS-KS code on uncertainty quantification of large break Loss of coolant accident (LBLOCA)

  • Lee, Ilsuk;Oh, Deogyeon;Bang, Youngseog;Kim, Yongchan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.755-763
    • /
    • 2020
  • The critical flow phenomenon has been studied because of its significant effect for design basis accidents in nuclear power plants. Transition points from thermal non-equilibrium to equilibrium are different according to the geometric effect on the critical flow. This study evaluates the uncertainty parameters of the critical flow model for analysis of DBA (Design Basis Accident) with the MARS-KS (Multi-dimensional Analysis for Reactor Safety-KINS Standard) code used as an independent regulatory assessment. The uncertainty of the critical flow model is represented by three parameters including the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio, and their ranges are determined using large-scale Marviken test data. The uncertainty range of the thermal non-equilibrium factor is updated by the MCDA (Model Calibration through Data Assimilation) method. The updated uncertainty range is confirmed using an LBLOCA (Large Break Loss of Coolant Accident) experiment in the LOFT (Loss of Fluid Test) facility. The uncertainty ranges are also used to calculate an LBLOCA of the APR (Advanced Power Reactor) 1400 NPP (Nuclear Power Plants), focusing on the effect of the PCT (Peak Cladding Temperature). The results reveal that break flow is strongly dependent on the degree of the thermal non-equilibrium state in a ruptured pipe with a small L/D ratio. Moreover, this study provides the method to handle the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio in the system code.

A Study on distribution of Dry Eye and Diagnosis Methods (건성안의 분포와 진단 방법에 대한 연구)

  • Ryu, Geun Chang;Park, Hyun Ju;Kim, Jae Min;Lee, Seung A;Ra, Myung Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.91-98
    • /
    • 2000
  • To investigate the distribution of dry eye and to accept diagnosis methods of dry eye in ophthalmic shop, this study was performed on 81 persons(male : 49, female : 32). 1. We divided two group for diagnosing dry eye by dry eye screening questionnaire : one was dry eye symptom group(49.3%) and the other was non-dry eye symptom group(50.7%). 2. Non-invasive break-up time(NIBUT) which was measured by using Tear $scope^{(R)}$ (Killer. co)was longer than invasive break-up time(IBUT). 3. A blink rate in dry eye symptom group(10%) was measured lesser than 10 cycle/min, in non-dry eye symptom group(14.9%). 4. In shirmer test there were lesser than 10mm/5min in dry eye symptom group(67.5%), in non-dry eye symptom group(39%). 5. Cornea and conjunctival staining by rose bengal represented Mild 25%, medium 36.25%, extreme 38.75% in dry eye symptom group. Non-dry eye symptom group was showed Mild 19.51%, medium 14.63%, extreme 12.19%. 6. These results showed that the patient showed dry eye symptom in 3 items of eye examination was 22.5%, 4 items 25%, 5 items 30%, 6 items 15%.

  • PDF

Comparison of tear film break-up time and high order aberration according to soft contact lens material (소프트콘택트렌즈 재질에 따른 눈물막 파괴시간과 고위수차의 비교)

  • Kim, Bong-Hwan;Han, Sun-Hee;Kim, Hak-Jun;Bae, Sang-A;Son, Yu-Jin;Kim, Ji-Hyun;KIm, Hyun-Ji
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1232-1237
    • /
    • 2019
  • Purpose. In this study, two types of soft contact lenses with different materials were selected to compare the time of tear film destruction and high order aberrations before and after wearing. Methods. Thirty patients (60 eyes) in their 20s were included in this study. Two lenses with different materials, Group 4 (Etafilcon A) and Group 5 (Narafilcon A) were selected. Using aberration analyzer and keratometry, high-order aberration and tear film test (NIF-BUT, NIAvg-BUT) were performed before and after wearing. Results. When comparing the higher aberrations of the Etafilcon A and Narafilcon A lenses, the higher aberrations of the Narafilcon A lens were higher overall. For the initial tear film break-up time (NIF-BUT) after wearing, the Etafilcon A lens was reduced by 4.0 seconds and the Narafilcon A lens increased by 0.6 seconds. For the mean tear film break-up time (NIAvg-BUT) after wearing, the Etafilcon A lens decreased by 2.4 seconds and the Narafilcon A lens increased by 1.7 seconds. Conclusions. NIF-BUT and NIAvg-BUT of Narafilcon A lens were increased. The lens with relatively low water content and higher oxygen permeability than the lens with high water content has relatively less tear evaporation, which means that the time of destruction of the tear film is increased.

SECOND ATLAS DOMESTIC STANDARD PROBLEM (DSP-02) FOR A CODE ASSESSMENT

  • Kim, Yeon-Sik;Choi, Ki-Yong;Cho, Seok;Park, Hyun-Sik;Kang, Kyoung-Ho;Song, Chul-Hwa;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.871-894
    • /
    • 2013
  • KAERI (Korea Atomic Energy Research Institute) has been operating an integral effect test facility, the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS), for transient and accident simulations of advanced pressurized water reactors (PWRs). Using ATLAS, a high-quality integral effect test database has been established for major design basis accidents of the APR1400 plant. A Domestic Standard Problem (DSP) exercise using the ATLAS database was promoted to transfer the database to domestic nuclear industries and contribute to improving a safety analysis methodology for PWRs. This $2^{nd}$ ATLAS DSP (DSP-02) exercise aims at an effective utilization of an integral effect database obtained from ATLAS, the establishment of a cooperation framework among the domestic nuclear industry, a better understanding of the thermal hydraulic phenomena, and an investigation into the possible limitation of the existing best-estimate safety analysis codes. A small break loss of coolant accident with a 6-inch break at the cold leg was determined as a target scenario by considering its technical importance and by incorporating interests from participants. This DSP exercise was performed in an open calculation environment where the integral effect test data was open to participants prior to the code calculations. This paper includes major information of the DSP-02 exercise as well as comparison results between the calculations and the experimental data.

Development of an Entrainment Model for the Steam Line Break Mass and Energy Release Analysis

  • Park, Young-Chan;Kim, Yoo
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.101-108
    • /
    • 2003
  • The purpose of this study is to develop an entrainment model of the Pressurized Water Reactor (PWR) U-tube Steam Generator (SG) for Main Steam Line Break (MSLB) analyses. Generally, the temperature of the inside containment vessel at MSLB is decreased by introducing the liquid entrainment effect. This effect makes a profit on the aspect of integrity evaluation for Equipment Environmental Qualification (EEQ) in the containment. However, the target plant, Kori unit 1 does not have the entrainment data. Therefore, this study has been performed. RETRAN-3D and LOFTRAN computer programs are used for the model development. There are several parameters that are used for the initial benchmark, such as Combustion Engineerings (CE) experimental data and the RETRAN-3D model which describes the test leg. A sensitivity study is then performed with this model in which the model parameters are varied until the calculated results provide reasonable agreement with the measured results for the entire test set. Finally, a multiplication factor has been obtained from the 95/95 values of the calculated (best-estimate) quality data relative to the measured quality data. With this new methodology, an additional temperature margin of about 40$^{\circ}C$ can be obtained. So, the new methodology is found to have an explicit advantage to EQ analyses.

Is the Fama French Three-Factor Model Relevant? Evidence from Islamic Unit Trust Funds

  • Shaharuddin, Shahrin Saaid;Lau, Wee-Yeap;Ahmad, Rubi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.5 no.4
    • /
    • pp.21-34
    • /
    • 2018
  • The study tests the Fama and French three-factor model by using the newly created Islamic equity style indices. Based on a dataset from May 2006 to April 2011, the three-factor model is tested based on returns of Islamic unit trust funds using the Generalized Method of Moments (GMM) methodology. The sample period is also divided between periods before and after the Global Financial Crisis in August 2008 to test for robustness, and the Bai and Perron (2003) multiple structural break test was used to determine the structural break in the series. The analysis shows that the Fama and French model is valid for Islamic unit trust funds before and after the collapse of Lehman Brothers. The result further indicates the reversal of size effect. As for trading strategies, value funds outperform growth funds by annualized 3.13 percent for the full period. During pre-crisis period, value funds perform better than growth funds while in post-crisis, size factor yields better return than other strategies. As policy suggestion, fund managers need to be aware of the reversal of size effect, and they need to ensure a more transparent stock selection process so that investors can make an informed decision in their asset allocation.

DEVELOPMENT OF A GARLIC CLOVE PLANTER

  • Park, W.K.;Kim, Y.K.;Choi, D.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.438-445
    • /
    • 2000
  • Positioning garlic cloves in upright standing in garlic field has been regarded as a very important job because it affects clove rooting, growing and, eventually, quality and yield in garlic production, Because of the geometrical uniqueness and irregularity of garlic cloves in shape, the planting operation has been conducted by manual work that needs a tremendous human labors and increases garlic production cost. The overall objective of this research was to develop garlic planting machine through investigating physical properties of garlic and designing clove upright positioning device after figuring out the factors affecting metering device and upright clove positioning mechanism. With the outcomes of the metering and posture positioning experiment, a garlic clove planter having twelve planting rows was developed for 37kW type tractor and feasibility test was carried out in the field. And, According to the performance test and cost analysis, the planter could accomplish planting operation of one hectare plot in 6.3 hours giving 48 times better efficiency, 6.3hrs/ha, and 74.2% of production cost reduction effect, 1,092,546won/ha, than the manual works of 299hrs/ha and 282,258won/ha. And, break-even point ofthe planter was calculated as of 2.71 hectares.

  • PDF

A SUMMARY OF 50th OECD/NEA/CSNI INTERNATIONAL STANDARD PROBLEM EXERCISE (ISP-50)

  • Choi, Ki-Yong;Baek, Won-Pil;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.561-586
    • /
    • 2012
  • This paper describes a summary of final prediction results by system-scale safety analysis codes during the OECD/NEA/CSNI ISP-50 exercise, targeting a 50% Direct Vessel Injection (DVI) line break integral effect test performed with the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS). This ISP-50 exercise has been performed in two consecutive phases: "blind" and "open" phases. Quantitative comparisons were performed using the Fast Fourier Transform Based Method (FFTBM) to compare the overall accuracy of the collected calculations. Great user effects resulting from the combination of the possible reasons were found in the blind phase, confirming that user effect is still one of the major issues in connection with the system thermal-hydraulic code application. Open calculations showed better prediction accuracy than the blind calculations in terms of average amplitude (AA) value. A total of nineteen organizations from eleven countries participated in this ISP-50 program and eight leading thermal-hydraulic system analysis codes were used: APROS, ATHLET, CATHARE, KORSAR, MARS-KS, RELAP5/MOD3.3, TECH-M-97, and TRACE.