SECOND ATLAS DOMESTIC STANDARD PROBLEM (DSP-02) FOR A CODE ASSESSMENT |
Kim, Yeon-Sik
(Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute)
Choi, Ki-Yong (Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute) Cho, Seok (Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute) Park, Hyun-Sik (Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute) Kang, Kyoung-Ho (Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute) Song, Chul-Hwa (Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute) Baek, Won-Pil (Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute) |
1 | M. Ishii and I. Kataoka, "Similarity Analysis and Scaling Criteria for LWRs Under Single Phase and Two-Phase Natural Circulation," NUREG/CR-3267, ANL-83-32, Argonne National Laboratory (1983). |
2 | H. S. Park et al., "An Assessment of a LBLOCA Similarity for a Reduced-Height Integral Effect Test Loop Design for PWRs," Annals of Nuclear Energy, 34, 931-937 (2007). DOI ScienceOn |
3 | S. Cho, et al., Quick loop report on the 6 inch cold leg SBLOCA test with the ATLAS, Technical Report for the SPACE code, S06NX08-A-1-TR-09, (2011). |
4 | A. Petruzzi and F.D'Auria, "Re-analysis of the ISP-13 Exercise, Post Test Analysis of the LOFT L2-5 Test Calculation," BEMUSE Phase II Report, NEA/CSNI/R(2006)2, (2006). |
5 | A. Prosek, F. D'Auria, B. Mavko, "Review of Quantitative Accuracy Assessments with Fast Fourier Transform Based Method (FFTBM)," Nuclear Engineering and Design, 217, 179-206, (2002). DOI ScienceOn |
6 | K.Y. Choi et al., "Comparison Report of Open Calculations for ATLAS Domestic Standard Problem (DSP-01), " KAERI/TR-4073/2010, Korea Atomic Energay Research Institute (2010). |
7 | Y.S. Kim et al., "First ATLAS Domestic Standard Problem (DSP-01) for the Code Assessment," Nuclear Engineering and Technology, 43, No.1, 25-44, (2011). 과학기술학회마을 DOI ScienceOn |
8 | K.Y. Choi et al., "ATLAS Domestic Standard Problem (DSP-02) Specifications," KAERI Internal Report, 53211-TS-002-R.03 (2011). |
9 | K.H. Kang et al., "Detailed Description Report of ATLAS Facility and Instrumentation," KAERI/TR-4316/2011, Korea Atomic Energay Research Institute (2011). |
10 | K.Y. Choi et al., "Comparison Report of Open Calculations for ATLAS Domestic Standard Problem (DSP-02), " KAERI/TR-4574/2012, Korea Atomic Energay Research Institute (2012). |
11 | Y.S. Kim, K.Y. Choi, H.S. Park, S. Cho, B.D. Kim, N.H. Choi, W.P. Baek, "Commissioning of the ATLAS thermal-hydraulic integral test facility," Annals of Nuclear Energy, 35, 1791-1799 (2008). DOI ScienceOn |
12 | K.Y. Choi, H.S. Park, S. Cho, D.J. Euh, Y.S. Kim, W.P.Baek, "Integral Behavior of the ATLAS Facility for a 3-inch Small Break Loss of Coolant Accident," Nuclear Engineering and Technology, 40, 199-212, (2008). 과학기술학회마을 DOI ScienceOn |