• Title/Summary/Keyword: Break Down Voltage

Search Result 74, Processing Time 0.021 seconds

The Design and Fabrication of RESURF type SOI n-LDMOSFET (RESURF type의 SOI n-LDMOSFET 소자 설계 및 제작)

  • Kim, Jae-Seok;Kim, Beom-Ju;Koo, Jin-Gen;Koo, Yong-Seo;An, Chul
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.355-358
    • /
    • 2004
  • In this work, N-LDMOSFET(Lateral Double diffused MOSFET) was designed and fabricated on SOI(Silicon-On-Insulator) substrate, for such applications as motor controllers and high voltage switches, fuel injection controller systems in automobile and SSR(Solid State Rexay)etc. The LDMOSFET was designed to overcome the floating body effects that appear in the conventional thick SOI MOS structure by adding p+ region in source region. Also, RESURF(Reduced SURface Field) structure was proposed in this work in order to reduce a large on-resistance of LDMOSFET when operated keeping high break down voltage. Breakdown voltage was 268v in off-state ($V_{GS}$=OV) at room temperature in $22{\mu}m$ drift length LDMOSFET. When 5V of $V_{GS}$ and 30V of $V_{DS}$ applied, the on resistance(Ron), the transcon ductance($G_m$) and the threshold voltage($V_T$) was 1.76k$\Omega$, 79.7uA/V and 1.85V respectively.

  • PDF

Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable. (전력케이블 절연재료의 내부결함에 따른 전기적 특성)

  • Choi, Sang-Gi;Kim, Tag-Yong;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF

Design of a One-Time Programmable Memory Cell for Power Management ICs (Power Management IC용 One-Time Programmable Memory Cell 설계)

  • Jeon, Hwang-Gon;Yu, Yi-Ning;Jin, Li-Yan;Kim, Du-Hwi;Jang, Ji-Hye;Lee, Jae-Hyung;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.84-87
    • /
    • 2010
  • We manufacture an antifuse OTP (One-time programmable) cell for analog trimming which will be used in power management ICs. For the antifuse cell using dual program voltage of VPP (=7V) and VNN (=-5V), the thin gate oxide is broken down by applying a voltage higher than the hard break-down voltage to the terminals of the antifuse. The area of the manufactured antifuse OTP cell using $0.18{\mu}m$ BCD process is $48.01{\mu}m^2$ and is about 44.6 percent of that of an eFuse cell. The post-program resistances of the antifuse are good with the values under several kilo ohms when we measure twenty test patterns.

  • PDF

A Study on the Grounding Resistance Effects of Lightning Arrester for Lightning Stroke Protection in Electric Distribution Systems (배전계통에서 낙뢰보호용 피뢰기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.107-114
    • /
    • 2010
  • Lightning is the discharging of high-voltage charged cells within clouds to earth other or to the earth. Lightning protection grounding is essential for the protection of buildings, distribution lines, and electrical equipment from lightning surges. Equipment grounding is for the purpose of controlling the voltage to earth within predictable limits. This paper investigates the effects of lightning arrester grounding resistance by analysing the neutral to earth voltages and arrester break down voltages when the lightning strike hits the distribution line. The case study was simulated numerically and graphically through the use of the EDSA software program.

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

The Characteristics of $PbTiO_{3}-PbZrO_{3}-Pb(Ni_{1/3}Nb_{2/3})O_{3}$ Piezoelectric Thin Film Made by Sol-Gel Method (Sol-Gel 법으로 제작한 $PbTiO_{3}-PbZrO_{3}-Pb(Ni_{1/3}Nb_{2/3})O_{3}$ 압전박막의 특성)

  • Yoon, Wha-Joong;Lim, Moo-Yeol;Koo, Kyung-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.75-80
    • /
    • 1995
  • In order to fabricate the piezoelectric thin film of the PZT-PNN ternary compound, the metal alkoxides were used as starting materials. The electrical and crystalline properties of the thin film were evaluated. The X- RD study shows that the crystallization of the film is optimized at $550^{\circ}C$ of sintering temperature. According to the D-E hysterisis curve, the coercive field is 28.8 kV /cm, and the remanent polariztion is $18.3\;{\mu}C/cm^{2}$. The break down voltages of the thin films are $76.0\;{\sim}\;27.0\;MV/m$. When the sintering temperature is raised, the break down voltage is lowered. As a result of measuring the C-V characteristic curve of the ternary compound piezoelectric thin film, the relative dielectric constants are 406 for the composition (50:40:10), 1084 for the composition (50:30:20), 723 for the composition (45:35:20) and 316 for the composition (40:40:20).

  • PDF

A Study on the Fabrication and Electrical Characteristics of Polyimide Nanocomposite as an Insulator between Turns of Superconducting Transformer (초전도 변압기용 turn간 절연재료용 Polyimide Nanocomposite의 제조 및 전기적 특성 연구)

  • 박영욱;이동성;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.105-108
    • /
    • 2002
  • Polyimide-epoxysilane (coupling agent) composites were reacted with oligomeric PDMS, a condensation product of difunctional silane, by a sol-gel process and were then dried into films. And then, the surface, mechanical, and electric properties were measured. The study showed that PDMS existed in the polyimlde matrix by the use of FT-IR. In the mechanical properties, the maximum elongation and toughness was increased in the polyimide with silane-groups. But the maximum tensile strength was slightly decreased. And the intensive dispersion of the silane-groups on the surface of polyimide was ascertained through XPS measurement. In the electric properties, AC break down voltage was increased by increasing the amount of difunctional silane. This experiment showed that PDMS added polyimide had better mechanical and electric properties than classical materials.

  • PDF

Lightning Protection of Signalling Equipments at Subway Car Depot by Equi-potential Bonding (지하철 차량기지에서의 등전위 본딩에 의한 신호시스템 낙뢰보호대책)

  • Seo, Seog-Chul;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.100-105
    • /
    • 2007
  • Signalling equipments at railroad sites are widely exposed to high voltage lightning surges. This paper presents a lightning protection system for the signalling equipments at subway car depots. The main features of the system are as follows : (1)the common grounding system between power system grounds and the signaling system grounds, (2)physical and chemical methods to reduce grounding resistivity, (3)rearrangement of lightning rods based on the rolling bal1 theory, (4)equi-potential bonding networks to minimize the potential differences between the equipments grounds. The system has been constructed at six subway car depots in Seoul metropolitan area and it is measured that the grounding resistivity are reduced to 0.266 ohms and the potential differences between devices are reduced to a negligible quantity. After the construction of the systems, it has not been reported the break-down of the signalling equipments caused by lighting surges.

A study on the protection system in electrified railways system (전철시스템에서의 보호시스템에 관한 연구)

  • Lee, Hee-Yong;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1342-1346
    • /
    • 2004
  • Recently, the load increasement and regenerative system of electrified railway system make a difficult to distinguish between the load current and fault current and it need a new intelligent protection system. The failure of traction system cause collapse of the other systems from high tension current. The over current from abnormal situation produces high tension current flow, high temperature are, voltage instability and current cutting, and break down railway systems. Protective system of traction system playa role of which detect and isolate failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

Development and Characteristics of a New Insulator between Turns of Superconducting Coil (초전도 Coil의 새로운 turn간 절연재료의 개발 및 특성)

  • 박영욱;이동성;이정원;곽동순;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.26-29
    • /
    • 2002
  • Polyimide-epoxysilane (coupling agent) composites were reacted with oligomeric PDMS, a condensation product of difunctional silane, by a sol-gel process and were then dried into films. And then, the surface, mechanical, and electric properties were measured. The study showed that PDMS existed in the polymide matrix by the use of FT-IR. In the mechanical properties, the maximum elongation and toughness was increased in the polyimide with silane-groups. But the maximum tensile strength was slightly decreased. And the intensive dispersion of the silane-groups on the surface of polyimide was ascertained through XPS measurement. In the electric properties. AC break down voltage was increased by increasing the amount of difunctional silane. This experiment showed that PDMS added polyimide had better mechanical and electric properties than classical materials.