• Title/Summary/Keyword: Brazing technology

Search Result 105, Processing Time 0.021 seconds

Development of Variable Vacuum Capacitor with Maximum Voltage of 12 kV and Capacitance of 50 to 500 pF (최대 전압 12 kV, 커패시턴스 50~500 pF 가변 진공커패시터 개발)

  • Cha, Youngkwang;Lee, Ilhoi;Jeon, Kibeom;Jang, Jihoon;Ju, Heungjin;Choi, aSeungkil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.3
    • /
    • pp.232-240
    • /
    • 2022
  • A variable vacuum capacitor (VVC), which is a variable element, is used to match impedance in plasma that changes with various impedance values, and its use is expanding with the rapid growth of the semiconductor business. Since VVCs have to secure insulation performance and vary capacitance within a compact size, electrode design and manufacturing are very important; thus, various technologies such as part design and manufacturing technology and vacuum brazing technology are required. In this study, based on the model of an advanced foreign company that is widely used for impedance matching in the manufacture of semiconductors and displays, a VVC that can realize the same performance was developed. The electrode part was designed, the consistency was confirmed through analysis, and the precision of capacitance was improved by designing a cup-type electrode to secure the concentricity of the electrode. As a result of the evaluation, all requirements was satisfied. We believe that self-development will be possible if satisfactory responses are received through evaluation by VVC consumers in the future.

Study on the material properties and heating efficiency according to the internal surface coating of the brazed plate heat exchanger (BPHE) (접합 판형 열교환기(BPHE)의 내부 코팅에 따른 소재 특성 및 성능 평가에 관한 연구)

  • Jung, Hangchul;Yang, Hyunseok;Kim, Hyunjong;Park, Jongpo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.6
    • /
    • pp.237-243
    • /
    • 2020
  • In this study, a silane-based coating was applied to improve corrosion resistance and thermal efficiency performance of a brazed plate heat exchanger (BPHE) composed of stainless plate and copper (Cu) brazing. Although the selected coating material was applied to the BPHE by evaluating the corrosion and contact angle according to the coating material, the result of the heat transfer performance evaluation showed that the thermal efficiency was lower than that of the uncoated BPHE. It was analyzed that the adhesion of the coating agent to the flow path inside the BPHE and the residual coating agent on the surface acted as heat resistance, preventing heat transfer. This is due to the structural characteristics of the BPHE in which a fine flow path exists inside, and it is believed that manufacturing after coating the surface of the flow path in advance in the manufacturing process of the BPHE can improve heat transfer performance.

Correlation Analysis of Cutter Acting Force and Temperature During the Linear Cutting Test Accompanied by Infrared Thermography (선형절삭시험과 적외선 열화상 측정을 통한 픽커터 작용력과 발생 온도의 상관관계 분석)

  • Soo-Ho Chang;Tae-Ho Kang;Chulho Lee;Hoyoung Jeong;Soon-Wook Choi
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.519-533
    • /
    • 2023
  • In this study, the linear cutting tests of pick cutters were carried out on a granitic rock with the average compressive strength over 100 MPa. From the tests, the correlation between the cutter acting force and the temperature measured by infrared thermal imaging camera during rock cutting was analyzed. In every experimental condition, the maximum temperature was measured at the rock surface where the chipping occurred, and the temperature generated in the rock was closely correlated with the cutter acting force. On the other hand, the temperature of a pick cutter increased up to only 36℃ above the ambient temperature, and the correlation with the cutter force was not obvious. This can be attributed to the short cutting distance under laboratory conditions and the high thermal conductivity of the tungsten carbide inserts. However, the relatively high temperature of the tungsten carbide inserts was found to be maintained. Therefore, it is recommended that a reinforcement between the insert and the head of a pick cutter or the quality improvement of silvering brazing in the production of a cutter is necessary to maintain the high cutting performance of a pick cutter.

Analysis of Two-Way Fluid-Structure Interaction and Local Material Properties of Brazed Joints for Estimation of Mechanical Integrity (관형 열교환기의 기계적 건전성 확보를 위한 유체-고체 연성해석과 브레이징 접합부의 국부적 물성분포 분석)

  • Kang, Seok Hoon;Park, Sang Hu;Min, June Kee;Jeong, Ho Sung;Son, Chang Min;Ha, Man-Young;Cho, JongRae;Kim, Hyun Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.9-16
    • /
    • 2013
  • Recent years have witnessed a strong need for eco-friendly and energy-efficient systems owing to global environmental problems. A heat exchanger is a well-known mechanical rig that has long been used in many energy systems. The use of a heat exchanger in an airplane engine has been attempted. In this case, the heat exchanger should be redesigned to be compact, lightweight, and highly reliable, and the issue of mechanical integrity gains importance. Therefore, in this study, we proposed a method for evaluating the mechanical integrity of a tube-type heat exchanger. A U-shaped single tube was used as an example, and its behavior and stress distribution were studied using fluid-structure interaction (FSI) analysis.

Fabrication and Performance of Anode-Supported Flat Tubular Solid Oxide Fuel Cell Unit Bundle (연료극 지지체식 평관형 고체산화물 연료전지 단위 번들의 제조 및 성능)

  • Lim, Tak-Hyoung;Kim, Gwan-Yeong;Park, Jae-Layng;Lee, Seung-Bok;Shin, Dong-Ryul;Song, Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.283-287
    • /
    • 2007
  • KIER has been developing the anode-supported flat tubular solid oxide fuel cell unit bundle for the intermediate temperature($700{\sim}800^{\circ}C$) operation. Anode-supported flat tubular cells have Ni/YSZ cermet anode support, 8 moi.% $Y_2O_3$ stabilized $ZrO_2(YSZ)$ thin electrolyte, and cathode multi-layer composed of Sr-doped $LaSrMnO_3(LSM)$, LSM-YSZ composite, and $LaSrCoFeO_3(LSCF)$. The prepared anode-supported flat tubular cell was joined with ferritic stainless steel cap by induction brazing process. Current collection for the cathode was achieved by winding Ag wire and $La_{0.6}Sr_{0.4}CoO_3(LSCo)$ paste, while current collection for the anode was achieved by using Ni wire and felt. For making stack, the prepared anode-supported flat tubular cells with effective electrode area of $90\;cm^2$ connected in series with 12 unit bundles, in which unit bundle consists of two cells connected in parallel. The performance of unit bundle in 3% humidified $H_2$ and air at $800^{\circ}C$ shows maximum power density of $0.39\;W/cm^2$ (@ 0.7V). Through these experiments, we obtained basic technology of the anode-supported flat tubular cell and established the proprietary concept of the anode-supported flat tubular cell unit bundle.