• 제목/요약/키워드: Branching rate

검색결과 77건 처리시간 0.022초

한국 잔디의 포복경 생장과 분지에 관한 연구 (The Study on the Growth and Branching of Stolon in Korean Lawn(Zoysia japonica Steud.))

  • 김용진;장남기
    • 아시안잔디학회지
    • /
    • 제11권2호
    • /
    • pp.117-124
    • /
    • 1997
  • This study was carried out to investigate the growth and branching pattern of stolons at Korean lawn(Zoysia japonica Steud.) in the field condition. The results were summarized as follows ; 1.About 80% of observed lawns had one primary stolon. Among the lawns with several primary stolons, 30% of them had two primary stolons, 63% had three, and 7% had four. 2.The angles between the primary stolon and the shoot were increased from 0˚ to 52˚ according to the node order from the terminal shoot apex, and reached maximum angle at the 7th node. 3.The internode length was the longest in the middle position of stolon, and its growing rate which depends on months was increased from May to September. 4.The branching angles between primary and secondary stolon were from 44˚ to 53˚ in each node. The average left branching angle was about 48.20, right branching angle 47.8˚, and the total average branching angle was 48.00. 5.The rate of initial brabch was the highest at the 10th node in May, the 7th node in July and the 5th node in September. But, the initial branching rate at the 7th node in July was higher than any other that at the 10th node in May and the 5th node in September. 6.The distribution rate of secondary stolon in each node of primary stolon was the highest at the 7th node. 7.when the terminal shoot apex of primary stolon was damaged mechanically, the branching rate at the first node after the damaged region was highly increased to 62%. The results of this study may be suggested that the secondary stolon begins to branch with the angle of 480 from the 7th node of the normal primary stolon, and those may be used as a basic data for the branching simulation in lawn.

  • PDF

Fatigue Crack Retardation and Retardation Mechanism in Variable Loading (The Effects of Crack Tip Branching in Crack Growth Retardation)

  • Song, Sam-Hong;Kwon, Yun-Ki
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권3호
    • /
    • pp.76-81
    • /
    • 2002
  • In order to study the fatigue crack and retardation mechanism in variable loading, the effects of crack tip branching in crack growth retardation were examined. The characteristics of crack tip branching behavior were considered with respect to microstructure and crack tip branching angle was examined. Crack tip branching was observed along the grain boundary of finite and pearlite structure. It was found that the branching angle ranges from 25 to 53 degrees. Using the finite element method, the variable of crack driving farce to branching angle was examined. The effective crack driving farce (K$\_$eff/) decreased as the branching angle increased. The rate of decrease was 33% for kinked type and 29% for forked one. It was confirmed that the effect of crack tip branching is a very important factor in crack growth retardation. Therefore, crack branching effect should be considered in building the hypothetical model to predict crack growth retardation.

메탈로센 선형 저밀도 폴티에틸렌의 결정화 거동 (Crystallization Characteristics of Metallocene Low Density Polyethylene)

  • 김경룡;한정우;조봉규;강호종
    • 폴리머
    • /
    • 제25권6호
    • /
    • pp.833-839
    • /
    • 2001
  • 광산란 장치를 이용하여 메탈로센 촉매 하에 제조된 메탈로센 선형 저밀도 폴리에틸렌의 결정화거동을 Ziegler-Natta 촉매에 의하여 제조된 선형 저밀도 폴리에틸렌과 비교하여 보았다. 특히 branching수와 길이 그리고 공단량체의 함량이 결정화 거동에 미치는 영향을 중점적으로 살펴보았다. 같은 수의 branching 수를 가지고 있는 메탈로센 선형 저밀도 폴리에틸렌은 기존의 선형 저밀도 폴리에틸렌에 비하여 결정화를 시작하기 위한 induction time이 길어짐을 알 수 있으나 구정의 성장속도는 두 경우가 유사함을 확인하였다. 메탈로센 선형 저밀도 폴리에틸렌의 branching 수를 감소시킬 경우 induction time과 구정성장속도가 모두 빨라짐을 알 수 있었다. 또한 일반적으로 최대 구정의 크기는 branching 수에 관계없이 메탈로센 선형 저밀도 폴리에틸렌이 기존의 선형 저밀도 폴리에틸렌에 비하여 커짐을 알 수 있었다.

  • PDF

변동하중하에서의 피로크랙 지연현상과 지연기구에 관한 연구 - 균열성장 지연현상에 미치는 균열 가지의 영향 - (A Study on Fatigue Crack Retardation and Retardation Mechanism in Variable Loading)

  • 송삼홍;권윤기
    • 한국정밀공학회지
    • /
    • 제14권6호
    • /
    • pp.83-89
    • /
    • 1997
  • In order to study on fatigue crack retardation and retardation mechanism in variable loading, the effects of crack tip branching in fatigue crack growth retardation were examined. The characteristics of crack tip banching behavior was considered to micro structure. It was examined that the variation of crack tip branching angle. Crack tip branching was observed along the grain boundary of ferrite and pearlite structure. It was found that the abanching angle ranges from 25 to 53 degrees. Using the finite element method, the variable of crack driving force to branching angle was examined. The effective crack driving force ( $K_{\eff}$ ) decreased as the braching angle increases. The rate of decrease was 33% for the kinked type and 29% for the forked one. It was confirmed that the effect of crack tip branching is a very important factor in fatigue crack growth retardation. Therefore, crack branching effect should be considered building the hypoth- etical model to predict crack growth retardation.

  • PDF

Energy- and Time-Dependent Branching to Competing Paths in Coupled Unimolecular Dissociations of Chlorotoluene Radical Cations

  • Seo, Jongcheol;Kim, Seung Joon;Shin, Seung Koo
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.833-838
    • /
    • 2014
  • The energy- and time-dependent branching to the competing dissociation paths are studied by theory for coupled unimolecular dissociations of the o-, m-, and p-chlorotoluene radical cations to $C_7{H_7}^+$ (benzylium and tropylium). There are four different paths to $C_7{H_7}^+$, three to the benzylium ion and one to the tropylium ion, and all of them are coupled together. The branching to the multiple paths leads to the multiexponential decay of reactant with the branching ratio depending on both internal energy and time. To gain insights into the multipath branching, we study the detailed kinetics as a function of time and internal energy on the basis of ab inito/RRKM calculations. The number of reaction steps to $C_7{H_7}^+$ is counted for each path. Of the three isomers, the meta mostly goes through the coupling, whereas the para proceeds with little or no coupling. In the beginning, some reactants with high internal energy decay fast to the benzylium ion without any coupling and others rearrange to the other isomers. Later on all three isomers dissociate to the products via long-lived intermediates. Thus, the reactant shows a multiexponential decay and the branching ratio varies with time as the average internal energy decreases with time. The reciprocal of the effective lifetime is taken as the rate constant. The resulting rate-energy curves are in line with experiments. The present results suggest that the coupling between the stable isomers is thermodynamically controlled, whereas the branching to the product is kinetically controlled.

소나무의 분지형에 관한 기하학적 연구 (A Geometrical Study of Branching Pattern in Pinus densiflora Siebold & Zuccarini)

  • Park, Bong Kyu;Hyeong Seon Choi
    • 환경위생공학
    • /
    • 제5권2호
    • /
    • pp.100-104
    • /
    • 1990
  • The geometrical branching pattern was studied through the time by a few parameters: the branching lengths, angles and number of branches. Ratios of moving amounts of nutrients between branches was decreased more in a terminal branch than in a proximal one. As the time increased, the more branches and leaves were also increased, while the influx of sunlight was decreased in the lower portion of inner crown which increased the mortality rate of branches.

  • PDF

고압하에서 수소-산소 확산화염의 소염 특성에 관한 수치 해석 (A numerical analysis on the extinction of hydrogen-oxygen diffusion flames at high pressure)

  • 손채훈;김종수;정석호;이수룡
    • 대한기계학회논문집B
    • /
    • 제21권9호
    • /
    • pp.1174-1184
    • /
    • 1997
  • Extinction characteristics of pure hydrogen-oxygen diffusion flames, at high pressures in the neighborhood of the critical pressure of oxygen, is numerically studied by employing counterflow diffusion flame as a model flame let in turbulent flames in rocket engines. The numerical results show that extinction strain rate increases almost linearly with pressure up to 100 atm, which can be explained by comparison of the chain-branching-reaction rate with the recombination-reaction rate. Since contributions of the chain-branching reactions, two-body reactions, are found to be much greater than those of the recombination reactions, three-body reactions, extinction is controlled by two-body reactions, thereby resulting in the linearity of extinction strain rate to pressure. Therefore, it is found that the chemical kinetic behaviors don't change up to 100 atm. Consideration of the pressure fall-off reactions shows a slight increase in extinction strain rate, but does not modify its linearity to pressure. The reduced kinetic mechanisms, which were verified at low pressures, are found to be still valid at high pressures and show good qualitative agreement in prediction of extinction strain rates. Effect of real gas is negligible on chemical kinetic behaviors of the flames.

The branching patterns and termination points of the facial artery: a cadaveric anatomical study

  • Vu Hoang Nguyen;Lin Cheng-Kuan;Tuan Anh Nguyen;Trang Huu Ngoc Thao Cai
    • 대한두개안면성형외과학회지
    • /
    • 제25권2호
    • /
    • pp.77-84
    • /
    • 2024
  • Background: The facial artery is an important blood vessel responsible for supplying the anterior face. Understanding the branching patterns of the facial artery plays a crucial role in various medical specialties such as plastic surgery, dermatology, and oncology. This knowledge contributes to improving the success rate of facial reconstruction and aesthetic procedures. However, debate continues regarding the classification of facial artery branching patterns in the existing literature. Methods: We conducted a comprehensive anatomical study, in which we dissected 102 facial arteries from 52 embalmed and formaldehyde-fixed Vietnamese cadavers at the Anatomy Department, University of Medicine and Pharmacy, Ho Chi Minh City, Vietnam. Results: Our investigation revealed eight distinct termination points and identified 35 combinations of branching patterns, including seven arterial branching patterns. These termination points included the inferior labial artery, superior labial artery, inferior alar artery, lateral nasal artery, angular artery typical, angular artery running along the lower border of the orbicularis oculi muscle, forehead branch, duplex, and short course (hypoplastic). Notably, the branching patterns of the facial artery displayed marked asymmetry between the left and right sides within the same cadaver. Conclusion: The considerable variation observed in the branching pattern and termination points of the facial artery makes it challenging to establish a definitive classification system for this vessel. Therefore, it is imperative to develop an anatomical map summarizing the major measurements and geometric features of the facial artery. Surgeons and medical professionals involved in facial surgery and procedures must consider the detailed anatomy and relative positioning of the facial artery to minimize the risk of unexpected complications.

지역냉방을 위한 아이스슬러리 시스템의 수송 및 분기 특성 (Ice slurry transporting and branching characteristics for the district cooling)

  • 이상훈;유호선;이윤표;이창준;권혁민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.662-667
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$), and the pumping power and branching characteristics are measured by transporting of the ice slurry. The ice slurry transporting pipe is as long as 200 m. For the same cooling load, the higher IPF is, the lower the transporting flow rate and the pumping power are. But when the IPF is higher than 15%, no less decrease of the pumping power does happen. For the branching characteristics, through the branch pipe where the flow resistance is higher, the higher IPF is measured. A little higher IPF is measured at the thermal expansion branch.

  • PDF

지역냉방용 직접순환식 아이스슬러리 시스템의 현장적용 사례 (A Field Application Case of Direct Ice Slurry Transporting System for District Cooling)

  • 유호선;이상훈;이윤표
    • 설비공학논문집
    • /
    • 제21권9호
    • /
    • pp.496-504
    • /
    • 2009
  • In order to investigate the feasibility of a direct ice slurry transporting system for the purpose of district cooling, a case study of field application is performed. The research aims include the field measurement of ice packing factor, the performance of coldness delivery, and the branching characteristics of ice slurry. Two representative types of pipe branch are dealt with in this work. For the slurry flow with ice volume fraction of 0.16 or less, the pipe blocking due to aggregation is not observed. Based on the time-wise variation of temperature in the storage tank, a calculating method of ice packing factor is newly developed, which seems to be useful when the brine concentration is unknown. It is confirmed that the mass flow rate of ice slurry per unit cooling load is markedly reduced with increasing the ice content. The pumping power also decreases, but remains unchanged for high ice fractions. The distribution of ice particle before and after branching shows a good uniformity within the range of 5% difference, but yields a unique trend depending on the flow rate.