• Title/Summary/Keyword: Branch line

Search Result 389, Processing Time 0.026 seconds

Fault Location for Incomplete-Journey Double-Circuit Transmission Lines on Same Tower Based on Identification of Fault Branch

  • Wang, Shoupeng;Zhao, Dongmei;Shang, Liqun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1754-1763
    • /
    • 2017
  • This paper analyses the characteristics of incomplete-journey double-circuit transmission lines on the same tower formed by single-circuit lines and double-circuit lines, and then presents a fault location algorithm based on identification of fault branch. With the relationship between the three-phase system and the double-circuit line system, a phase-mode transformation matrix for double-circuit lines can be derived. Based on the derived matrix, the double-circuit lines with faults can be decoupled, and then the fault location for an incomplete-journey double-circuit line is achieved by using modal components in the mode domain. The algorithm is divided into two steps. Firstly, the fault branch is identified by comparing the relationships of voltage amplitudes at the bonding point. Then the fault location, on the basis of the identification result, is calculated by using a two-terminal method, and only the fault distance of the actual fault branch can be obtained. There is no limit on synchronization of each terminal sampling data. The results of ATP-EMTP simulation show that the proposed algorithm can be applied within the entire line and can accurately locate faults in different fault types, fault resistances, and fault distances.

Analytical Modeling of Conventional and Miniaturization Three-Section Branch-Line Couplers

  • You, Kok Yeow;AL-AREQI, Nadera;Chong, Jaw Chung;Lee, Kim Yee;Cheng, Ee Meng;Lee, Yeng Seng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.858-867
    • /
    • 2018
  • Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of broadband S-parameters analysis. In addition, a bandwidth extension and miniaturization of three-section branch-line coupler using slow-wave and meandering line structures were designed. The modified coupler, which is able to operate within frequencies from 1.5 to 3.32 GHz has been fabricated, tested and compared. A bandwidth extension of 600 MHz and 53% reduced size of the modified coupler have been achieved compared to a conventional coupler. The modified coupler has roughly insertion loss and coupling of -4 dB and -3.2 dB, while the isolation and return loss, respectively less than -14 dB with fractional bandwidth of 77 %, as well as phase imbalances less than $2^{\circ}$ over the operating bandwidth. Overall, the derived analytical model, simulation and measurement results demonstrated a good agreement.

Design and Implementation of Fishing Gear Type Setting System for Long Line (연승어업을 위한 어구 유형 설정 시스템의 설계 및 구현)

  • 이태오;윤희철;임재홍
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.111-116
    • /
    • 2004
  • A fishing gear is an used tool to achieve fishery effectively. Especially, long line is fishery method to confect branch line to fixed space to main line and bind fishhook 1 in branch line end. This paper presents the design and implementation of fishing gear type setting system for fishing gear layout management in the long line work. In this paper, we design overall fishing gear type setting system. For this purpose, the modules such as system user and communication environment setting module, fishing gear type setting module, module of fishing gear shooting model are designed and implemented. For the validity evaluation of this paper, fishing gear type design and shooting process are implemented and tested.

  • PDF

Design of A Dual Band Branch Line Coupler Using a CRLH Transmission Line Structure (CRLH 전송선로 구조를 이용한 이중대역 브랜치 라인 커플러 설계)

  • Park, Min-Woo;Koo, Ja-Kyung;Lim, Jong-Sik;Jeong, Yong-Chae;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2462-2467
    • /
    • 2009
  • This paper proposes a dual band branch line coupler (BLC) using a composite right/left handed (CRLH) transmission line. The existing dual band BLCs with open stubs require hundreds of line impedance for the open stub as the frequency bands approach to each other, so it has been almost impossible to realize them. However in the proposed BLC, a CRLH transmission line replaces the open stub with an extremely high line impedance so that the BLC circuit may be realized even two frequencies are close to each other. As an example, a dual band BLC operating at 1800MHz and 2300MHz (the frequency ratio is 1:1.28) is designed and measured. Open stubs with $560\Omega$ line impedance are replaced by CRLH transmission lines for realizing the dual band BLC. The measured performances prove that the dual band operation is well acceptable and the proposed design method is successful even the ratio between two frequencies is not around two nor more.

Dual-Band Branch-Line Coupler Using Shorted Stubs (단락 스터브를 이용한 이중대역용 브랜치 라인 커플러의 설계)

  • Kim, Jong-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.54-59
    • /
    • 2013
  • This letter presents a shorted-stub tapped branch-line coupler for dual-band applications. In the new design, a shorted stub is used to realize 90 phase change at two frequencies. Closed-form design equations are derived to find the characteristic impedance and electrical length of the proposed branch lines using the ABCD-matrix. To verify the design concept, a microstrip coupler operating at 0.8 and 1.85 GHz is fabricated and measured.

The Study for Analysis and Prevention Measure of Overhead Transmission Line Fault with Birds (조류에 의한 가공송전선로의 고장분석 및 예방대책 고찰)

  • Jung, Si-Hwan;Kang, Cheul-Won;Kim, Wan-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.96-98
    • /
    • 2006
  • Recently major power outages are increased, because of transmission line fault by birds. Therefore, after finding out the problem of the current prevention measure for the super high voltage transmission Line in Korea and analyzing the protection measure of other foreign power companies for the transmission facilities fault by birds, this paper describes an effective device for power line fault protection by birds which has no legal problem and also protects birds. The described prevention measure of power outage by birds in this paper, has a special feature that is able to be installed on the current overhead transmission facilities without a replacement or change.

  • PDF

Analysis and Design of Branch Line Coupler using Microstrip Lines with Overlay (덮개층이 있는 마이크로스트립 선로를 이용한 브랜치 선로 결합기 해석 및 설계)

  • 이승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.795-801
    • /
    • 2001
  • A method of miniaturizing branch line coupler is presented. The method utilizes the microstrip line with overlay(or superstrate). The frequency dependent characteristics, dispersion and characteristic impedance, of this line are obtained by Immitance method in spectral domain and Method of Line. The relevant spectral domain Green's function is given and used to obtain numerical results. The branch line couplers with overlays are designed and fabricated at 2 GHz. The experimental results show that the size of coupler with overlay(${epsilon}_r$=10.2) is 31.4 precent smaller than conventional coupler. This minimized coupler is suitable for Butler Matrix as feeder for mobile communication beam forming antenna.

  • PDF

Analysis of Surge Behavior and Protection Method in the Underground Distribution Systems with Branch Lines (분기선로가 포함된 지중배전계통에서 서지특성 해석 및 보호방안에 관한 연구)

  • Lee, Jang-Geun;Lee, Jong-Beom;Lee, Jae-Bong;Kim, Byoung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.148-150
    • /
    • 2006
  • This paper describes the overvoltage at the branch line in underground distribution systems when the direct lightning surge strikes on conductor of overhead line. Distribution systems are very complex because it includes many branch lines, transformers, switches and so on. Therefore model system consists of overhead distribution lines, underground cable include branch lines, lightning source and switches. Analysis are performed using EMTP to understand and evaluate the surge behavior on branch lines considering various conditions in underground distribution systems. Simulation results show overvoltage with location in various cases. It is evaluated that result will be used to establish protection methods in actual underground distribution systems.

  • PDF

Numerical Analysis Study of the Mixing Mechanism of Non-element Mixer (논 엘레멘트 믹서의 혼합 메커니즘에 관한 수치해석적 검토)

  • You, Sun Ho
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Visualization of the mixing pattern in a non-element mixer was carried out using laser induced fluorescence(LIF) to evaluate characteristics of mixer consisting of the main flow pipe and branch flow pipes. The branch flows were injected periodically with the period $T_{in}$ normal to the main flow, and rhodamine B was mixed into the most upstream branch flow to visualize mixing pattern in the main flow pipe by LIF. The length of boundary line L of the LIF image was measured. In this study, a numerical analysis was performed to identify the mixing process of the non-element mixer, and the results were compared with experimental results. Each result was almost the same. When the number of branch flows is increased, the mixing pattern became complicated and was supposed to become chaotic. The length of boundary line L increased exponentially with an increase in the number of branch flows.

A Study on the Reflection Type Analog Phase Shifter using Varactor and Branch Coupler (가변 캐패시터와 Branch Coupler를 이용한 반사형 아날로그 위상 변위기 연구)

  • 유강희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3A
    • /
    • pp.311-317
    • /
    • 2004
  • A low loss reflection type analog phase shifter which is realized with two varactors and branch coupler. is described. A new design technique for the large phase shift is applied using short stub microstripe lines. This paper presented the realization of design and experimental results. Through the experiment using the duroid microstrip line and varactors, the phase of 2.26GHz signal is controlled to the DC voltage with the phase shift range of 170$^{\circ}$. The achieved insertion loss of less than 3㏈ and the return loss of mote than 12㏈ are achieved over all phase states.